DOI QR코드

DOI QR Code

Development of Wireless Real-Time Gas Detector System for Chemical Protection Performance Test of Personal Protective Equipment

화생방 보호의 성능평가를 위한 무선 실시간 가스 검출기 개발

  • Kah, Dong-Ha (The 4th Research and Development Institute, Agency for Defense Development)
  • 가동하 (국방과학연구소 제4기술연구본부)
  • Received : 2020.03.17
  • Accepted : 2020.05.22
  • Published : 2020.06.05

Abstract

Man-In-Simulant Test(MIST) provides a test method to evaluate chemical protective equipments such as protective garments, gloves, footwear and gas mask. The MIST chamber is built to control concentration of chemical vapor that has a activity space for two persons. Non-toxic methyl-salicylate(MeS) is used to simulate chemical agent vapor. We carried out to measure inward leakage MeS vapors by using passive adsorbent dosimeter(PAD) which are placed on the skin at specific locations of the body while man is activity according to the standard procedure in MIST chamber. But more time is required for PADs and there is concern of contamination in PADs by recovering after experiment. Therefore detector for measuring in real time is necessary. In order to analyze in real time the contamination of the personal protective equipment inside the chemical environment, we have developed a wireless real-time gas detector. The detector consists of 8 gas-sensors and 1 control-board. The control-board includes a CPU for processing a signal, a power supply unit for biasing the sensor and Bluetooth-chipset for transmission of signals to external PC. All signals from gas-sensors are converted into digital signals simultaneously in the control-board. These digital signals are stored in external PC via Bluetooth wireless communication. The experiment is performed by using protective equipment worn on manikin. The detector is mounted inside protective equipment which is capable of providing a real-time monitoring inward leakage MeS vapor. Developed detector is demonstrated the feasibility as real-time detector for MIST.

Keywords

References

  1. Hyunsook Jung et. al., "Facile Fabrication of Chemical Vapor Samplers with Various Adsorbents for Man-in-Simulant Test(MIST)," Journal of the Korea Institute of Military Science and Technology, 17, pp. 129-134, 2014. https://doi.org/10.9766/KIMST.2014.17.1.129
  2. Heesoo Jung and Haewan Lee, "Body Region Hazard Analysis of Chemical Protective Ensembles using by Various Body Surface Areas," 2015 Chemical and Biological Defense Science and Technology, 2015.
  3. Charles Walker, "Chemical Vapor and Aerosol System -Level Testing of Chemical/Biological Protective Suit, Test and Evaluation Capabilities and Methodologies Integrated Process Team(TECMIPT) Test Operation Procedure(TTOP) 10-2-022A," U. S. Army Dugway Proving Ground, West Desert Test Center, 2013.
  4. US Patent 5726068, "Diffusive Sampler System for Determining Chemical Vapor Levels".
  5. TGS2600, www.figarosensor.com
  6. C. Schuh and P. Schieberle, "Characterization of the Key Aroma Compounds in the Beverage Prepared from Darjeeling Black Tea: Quantitative Differences between Tea Leaves and Infusion," Journal of Agriculture and Food Chemistry, Vol. 54, pp. 916- 924, 2006. https://doi.org/10.1021/jf052495n
  7. ALI, Sk Babar, "Development of Metal Oxide based Semiconductor Sensors for Tea Aroma," 2010, PhD. Thesis, Jadavpur University, 2010.
  8. Matthews, J. B. et. al., "The Vapour Pressures of Certain Liquids," Transaction of the Faraday Society, 46, 1950.
  9. Thermo Scientific MIRAN SapphlRE Potable Ambient Aanlyzer, www.thermofisher.com
  10. Robert B. Ormond, "Advancement in the Man-In-Simulant-Test Methodology and Development of Next Generation Manikin for Chemical and Biological Protection Research," Fiber and Polymer Science, Raleigh, North Carolina State University, 2012.
  11. Richard Burke et. al., "Integrating an Active Physiological and Comfort Model to the Newton Sweating Thermal Manikin," Proceedings of the 13th International Conference on Environmental Ergonomics, pp. 313-317, 2009.