DOI QR코드

DOI QR Code

Anchorage Strength of High Strength Headed Bar Embedded Vertically on SFRC Members

SFRC 부재에 수직 배근된 고강도 확대머리철근의 정착강도

  • 이창용 (한밭대학교 건축공학과) ;
  • 김승훈 (한밭대학교 건축공학과)
  • Received : 2020.02.04
  • Accepted : 2020.02.13
  • Published : 2020.02.29

Abstract

The paper is a summary of the results of the basic pullout test which is conducted to evaluate the anchorage capacity of high strength headed bars that is mechanical anchored vertically on steel fiber reinforced concrete members. The main experimental parameters are volume fraction of steel fiber, concrete strength, anchorage length, yield strength of headed bars, and shear reinforcement bar. Both sides of covering depth of the specimen are planned to double the diameter of the headed bars. The hinged point is placed at the position of each 1.5𝑙dt and 0.7𝑙dt around the headed bars, and the headed bars are drawn directly. As a result of pullout test experiment, concrete fracture and steel tensile rupture appear by experimental parameters. The compressive strength of concrete is 2.7~5.4% higher than that of steel fiber with the same parameters, while the pullout strength is 20.9~63.1% higher than that of steel fiber without the same parameters, which is evaluated to contribute greatly to the improvement of the anchorage capacity. The reinforcements of shear reinforcements parallel to the headed bars increased 1.7~7.7% pullout strength for steel fiber reinforced concrete, but the effect on the improvement of the anchorage capacity was not significant considering the increase in concrete strength. As with the details of this experiment, it is believed that the design formula for the anchorage length of KCI2017and KCI2012 are suitable for the mechanical development design of SD600 head bar that is perpendicular to the steel fiber reinforced concrete members.

본 논문은 강섬유 보강 콘크리트 부재에 수직으로 기계적 정착된 고강도 확대머리철근의 정착성능을 평가하기 위하여 실시한 기초 인발실험결과를 정리한 것이다. 주요 실험변수는 강섬유의 혼입률, 콘크리트 강도, 정착길이, 확대머리철근 항복강도, 전단보강유무 등이다. 실험체의 좌우 순피복두께는 확대머리철근 직경의 두 배로 계획하였다. 확대머리철근을 중심으로 1.5𝑙dt, 0.7𝑙dt가 되는 위치에 힌지 지점을 두고, 확대머리 철근을 직접 인발하였다. 인발실험결과, 실험변수에 따라 콘크리트 파괴 및 철근 인장파단이 나타났다. 강섬유를 보강한 실험체가 동일한 변수의 강섬유를 보강하지 않은 실험체에 비히여 콘크리트 압축강도는 2.7~5.4% 크게 나타난 반면 인발강도는 20.9~63.1% 크게 나타나 정착성능 향상에 큰 기여를 하는 것으로 평가되었다. 강섬유 보강 콘크리트에 대해 확대머리철근과 평행한 전단보강근의 배근은 1.7~7.7% 인발강도를 증가시켰으나, 콘크리트 강도 증가를 고려할 때 정착성능 향상에 미치는 영향이 크지 않았다. 본 실험체 상세와 같이 강섬유보강 콘크리트 부재에 수직정착된 SD600의 확대머리철근 정착설계는 KCI2017, KCI2012의 정착길이 설계식을 그대로 사용할 수 있을 것으로 사료된다.

Keywords

References

  1. ACI Committee 352. (2002), Code requirements for nuclear safety related concrete structures, (ACI352-02).
  2. ACI Committee 349. (2007), Code requirements for nuclear safety related concrete structures, (ACI349-07).
  3. Thompson, M.K., Jirsa, J.O.&Breen, J.E. (2006), CCT nodes anchored by headed bars-Part 2 : Capacity of nodes, ACI structural Journal, 103(1), 65-73.
  4. ACI Committee 318. (2008), Code requirements for nuclear safety related concrete structures, (ACI318-08).
  5. Yong-Taeg Lee, Seung-Hum Kim, Seo-Ho Chea, Byong-Youl Bahn. (2008), An experimental study on the lap strength of headed steel reinforcements with lap-spliced, Journal of the Architectural Institute of Korea structure&construction, 24(3), 87-94.
  6. KCI Committee. (2012), Concrete Design Code and Commentary, Korea Concrete Institute, (KCI 2012).
  7. ACI Committee 318. (2014), Code requirements for nuclear safety related concrete structures, (ACI318-14).
  8. Seung-Hum Kim. (2014), Experimental study on lap splice of headed deformed reinforcing bars in tension, Journal of the Korea Institute for Structural Maintenance and Inspection, 18(5), 59-67. https://doi.org/10.11112/jksmi.2014.18.5.059
  9. Sung-Chul Chun, Min-Seo Bae, Ki-Hoon Moon, Tae-hun Ha. (2015), Comparison of code provisions on transverse reinforcement of exterior beam-column joints, Journal of the Korea Concrete Institute, 267-268.
  10. Seung-Hum Kim. (2015), Experimental study on effect of confinement details for lap splice of headed deformed reinforcing bars in grade sd400 and sd500, Journal of the Korea Institute for Structural Maintenance and Inspection, 19(1), 62-71. https://doi.org/10.11112/jksmi.2015.19.1.062
  11. Jeong-Ho Moon, Young-Hun Oh. (2015), Development length effects of high strength headed bar, Journal of the Korea Institute for Structural Maintenance and Inspection, 19(5), 75-082. https://doi.org/10.11112/jksmi.2015.19.5.075
  12. Sung-Chul Chun, Hye-Jung Sim, Min-Seo Bae, Mun-Gil Kim, Byung-Sool Lee. (2016), Anchorage strength of high-strength large-diameter headed bar in CCT nodes, Journal of the Korea Concrete Institute, 28(1), 753-754.
  13. Seung-Hum Kim. (2016), Lap details using headed bar and hooked bars for flexural members with different depths, Journal of the Korea Institute for Structural Maintenance and Inspection, 19(1), 62-71. https://doi.org/10.11112/jksmi.2015.19.1.062
  14. KDS Center 14 20. (2016), Korea Design Standard, Korea Construction Standards Center, (KCSC).
  15. Hye-Jung Sim, Sung-Chul Chun, Sokhwan Choi. (2016), Anchorage strength of headed bars in steel fiber-reinforced UHPC of 120 and 180 MPa, Journal of the Korea Concrete Institute, 28(3), 365-373. https://doi.org/10.4334/JKCI.2016.28.3.365
  16. Seung-Hun Kim, Kyu-Seon Lee, Yong-Taeg Lee. (2017), An experimental study on the evaluation of shear performance of PVA fiber reinforced RC deep beam with high strength headed rebar, Architectual rexearch, 19(4), 109-115.
  17. KS F 2405. (2017), Standard test method for conpressive strength of concrete, Korean agency for technology and standards.
  18. Hye-Jung Sim, Sung-Chul Chun. (2018), A reevaluation of anchorage strength of headed bars in exterior beam-column joints, Journal of the Korea Concrete Institute, 30(2), 207-216. https://doi.org/10.4334/JKCI.2018.30.2.207
  19. Seunghun Kim, Sungchol Peak, Changyong Lee, Hyunwoong Yuk, Yongtaeg Lee. (2018), Development strength of headed reingorcing bars for steel fiber reinforced concrete by pullout test, Architevtural research, 20(4), 129-135.
  20. KS B 0802. (2018), Method of tensile test for metallic materials, Korean agency for technology and standards.