References
- Bo Kyung Cha, Jeong-Hyun Shin, Jun Hyung Bae, et al., Scintillation characteristics and imaging performance of CsI:Tl thin films for X-ray imaging applications, Nucl. Instrum. Methods Phys. Res. 604 (2009) 224-228. https://doi.org/10.1016/j.nima.2009.01.177.
- E. Seeram, Digital mammography:an overview, Can. J. Med. Radiat. Technol. 36 (2006) 15-23. https://doi.org/10.1016/S0820-5930(09)60082-7.
- M.T. Gerieke, C. Blessingeret, et al., A current mode detector array for g-ray asymmetry measurements, Nucl.Instr. and Meth A 540 (2005) 328-347. https://doi.org/10.1016/j.nima.2004.11.043.
- Hamamatsu technical data sheet H8500-H8500B, H9500, printed in Japan, http://www.hamamatsu.com, February 2005.
- R. Pani, et al., Imaging detector designs based on flat panel PMT, Nucl. Instrum. Methods A 527 (2004) 54-57. https://doi.org/10.1016/j.nima.2004.03.037.
- M. Gimenez, J. M Benlloch, et al., Medium field of view multiflat panel-based portable gamma camera, Nucl. Instrum. Methods A 525 (2004) 298-302. https://doi.org/10.1016/j.nima.2004.03.077.
- D. Herbert, N. Belcari, et al., A comparison of the imaging performance of different PSPMTs for PET applications, Nucl. Instrum. Methods A 518 (2004) 399-400. https://doi.org/10.1016/j.nima.2003.11.033.
- C. Trotta, R. Massari, N. Palermo, et al., New high spatial resolution portable camera in medical imaging, Nucl. Instrum. Methods A 577 (2007) 604-610. https://doi.org/10.1016/j.nima.2007.03.037.
- J. Kindem, C. Bai, R. Conwell, CsI(Tl)/PIN solid state detector for combined high resolution SPECT and CT imaging, Proc. IEEE Nucl. Sci. Symp. (2010) 1987-1990. https://doi.org/10.1109/NSSMIC.2010.5874123.
- W. Siman, S.C. Kappadath, Performance characteristics of a new pixelated portable gamma camera, Med. Phys. 39 (2012) 3435-3444. https://doi.org/10.1118/1.4718874.
- Ruo-Fu Chen, X.U. Hu-Shan, et al., Property measurement of the CsI(Tl) crystal prepared at IMP, Chin. Phys. C 32 (2008) 135-138. https://doi.org/10.1088/1674-1137/32/2/012
- Qi Hui Rong, Jin chuan Wang, Guo qing Xiao, et al., Investigation of predigested processing 64 signals of flat-panel PMT, Nucl. Electron. Detect. Technol. 26 (2006) 450-453 (in Chinese). https://doi.org/10.3969/j.issn.0258-0934.2006.04.016
- S. Siegel, R.W. Silverman, Shao YiPing, et al., Simple charge division readouts for imaging scintillator arrays using a multi-channel PMT, IEEE Trans. Nucl. Sci. 43 (1996) 1634-1641. https://doi.org/10.1109/23.507162.
-
David Stratos, Georgiou Maria, et al., Comparison of three resistor network division circuits for the readout of
$4{\times}$ 4 pixel SiPM arrays, Nucl. Instrum. Methods Phys. Res. 702 (2013) 121-125. https://doi.org/10.1016/j.nima.2012.08.006. - S. Vecchio, M. Camarda, et al., Preliminary study of different readout strategies for a positron emission mammograph head, Nucl. Instrum. Methods Phys. Res. 569 (2006) 264-268. https://doi.org/10.1016/j.nima.2006.08.025.
- C.J. Borkowski, M.K. Kopp, Some applications and properties of one-and twodimensional position sensitive proportional counter, IEEE Trans. Nucl. Sci. 17 (1970) 340-349. https://doi.org/10.1109/TNS.1970.4325710.
- V. Popov, et al., IEEE Nuclear Science Symposium Conference Record (2003) 2156.
Cited by
- A Novel Portable Gamma Radiation Sensor Based on a Monolithic Lutetium-Yttrium Oxyorthosilicate Ring vol.21, pp.10, 2021, https://doi.org/10.3390/s21103376