시공정밀도에 따른 비구조용 콘크리트벽돌 조적벽체의 프리즘 압축강도

Prism Compressive Strength of Non-structural Concrete Brick Masonry Walls According to Workmanship

  • 투고 : 2019.12.04
  • 심사 : 2020.01.30
  • 발행 : 2020.02.28

초록

Prism compressive strength is the most influential parameter to evaluate the seismic performance of non-structural concrete brick masonry walls, and is affected by the practice and workmanship of masonry workers. This study experimentally investigates the influence of workmanship on prism compressive strength throughout the compressive test with prism specimens constructed according to masonry workmanship. To do this, the workmanship is categorized into good, fair, and poor conditions which are statistically evaluated with thickness and indentation depth of bed-joints. Then, the effect of workmanship on the structural properties of masonry prisms is evaluated by investigating relations between properties such as their compressive strength, elastic modulus and numerical parameters such as thickness, filling of bed-joints. This study demonstrates that the indentation depth is more important parameter for structural properties of masonry prisms and masonry prisms with loss in bed-joint area less than of 7% can be in fair condition.

키워드

과제정보

연구 과제 주관 기관 : 국토교통부

본 연구는 국토교통부 도시건축 연구개발사업의 연구비 지원(20AUDP-C146352-03)에 의해 수행되었습니다.

참고문헌

  1. Ministry of Construction & Transportation (MCT) (2006). A study on a method of the improving the seismic performance of unreinforced masonry structures and realizing high-rise buildings with using masonry finishing, Ministry of Construction & Transportation, Korea Institute of Construction & Transportation Technology Evaluation and Planning.
  2. National Disaster Management Institute (NDMI) (2008). Developmemnt of the Seismic Fragility Function for Unreinforced Masonry Buildings, National Disaster Management Institute, National institute for disaster prevention.
  3. Oh, S., & Shin, S. (2016). Correlation Analysis if Gyeongju Earthquake Waveform and Structural Damage Scale, Journal of the Architectural Institute of Korea Structure & Construction, 32(12), 33-44. https://doi.org/10.5659/JAIK_SC.2016.32.12.33
  4. Ministry of Land Infrastructure, and Transport (MLIT) (2016). Korean Construction Specification, KCS 41 34 01 : 2016, Masonry Construction, Ministry of Land Infrastructure, and Transport, Korea Construction Standards Center.
  5. Tabbakhha M., Modaressi-Farahmand-Razavi, A. (2016). Analyzing the effect of workmanship quality on performance of unreinforced masonry walls through numerical methods, Computers and Structures, 167, pp.1-14. https://doi.org/10.1016/j.compstruc.2016.01.013
  6. Hendricks, R., Schueremans, L., Verstrynge, E., Van Balen, K., & Van Gemert, D. (2008). Effect of mortar type and workmanship on the behavior of masonry under uniaxial compression, 14th international Brick & Masonry Conference.
  7. Groot, C., Gunneweg, J. T. M. (2010). The influence of materials characteristics and workmanship on rain penetration in historical field brick masonry, Heron, 55(2), pp. 141-154.
  8. Korea Infrastructure Safety and Technology Corporation (KISTC) (2013). Guidelines for Seismic Evaluation of Existing Buildings, Ministry of Land, Transport and Maritime Affairs, Korea Infrastructure Safety and Technology Corporation.
  9. Korea Agency for Technology and Standards (KATS) (2018). Concrete Bricks, KS F 4004, Korea Agency for Technology and Standards.
  10. Kim, H., Kim, K., Park, J., & Ha, W. (2001). Experimental Study on the Material Properties of Unreinfoced Masonry Earthquake Load, Journal of Earthquake Engineering Society of Korea, 5(2), 93-101.
  11. Yi, W., Lee, J., Oh, S., Yang, W., & Kang, D. (2005). A Study on Evaluation of Shear Capacity of Unreinforced Masonry Wall, Journal of the Architectural Institute of Korea Structure & Construction, 21(10), 3-10.
  12. University of Seoul (UOS) (2001). Seismic Retrofit Methods of Unreinforced Masonry Structures, University of Seoul, Laboratory of Earthquake Disaster Prevention, pp. 1-263.
  13. American Society of Civil Engineering (ASCE) (2006). Seismic Evaluation and Retrofit of Existing Buildings, American Society of Civil Engineers, Standards ASCE/SEI 41-06, American Society of Civil Engineering, Virginia, U.S.A.
  14. American Society of Civil Engineers (ASCE) (2013). Seismic Evaluation and Retrofit of Existing Buildings, American Society of Civil Engineers, Standards ASCE/SEI 41-13, American Society of Civil Engineering, Virginia, U.S.A.
  15. American Society of Testing and Materials (ASTM) (2018). Standard Test Method for Compressive Strength of Masonry Prisms, C1314-18, American Society of Testing and Materials, West Conshohocken, PA, USA.
  16. Korea Agency for Technology and Standards (KATS) (2017). Masonry cement, KS L 5219, Korea Agency for Technology and Standards.
  17. Korea Infrastructure Safety and Technology Corporation (KISTC) (2019). Guidelines for Seismic Evaluation of Existing Buildings, Ministry of Land, Infrastructure and Transport, Korea Infrastructure Safety and Technology Corporation.
  18. Federal Emergency Management Agency (FEMA) (2000). Prestandard and Commentary for the Seismic Rehabilitation of Buildings, FEMA 356, American Society of Civil Engineers, Federal Emergency Management Agency, Washington, D. C., U.S.A.
  19. The Masonry Society (TMS) (2016). Building Code Requirements and Specification for Masonry Structures, TMS 402/602-16, The Masonry Society, Longmont, CO, U.S.A.