References
- DeBoer J. Edentulous implants: overdenture versus fixed. J Prosthet Dent 1993;69:386-90. https://doi.org/10.1016/0022-3913(93)90186-R
- Ohkubo C, Kobayashi M, Suzuki Y, Hosoi T. Effect of implant support on distal-extension removable partial dentures: in vivo assessment. Int J Oral Maxillofac Implants 2008;23:1095-101.
- Lee JH, Kim DG, Park CJ, Cho LR. A literature review on implant assisted removable partial denture. J Dent Rehabil Appl Sci 2012;28:179-90.
- Mijiritsky E, Karas S. Removable partial denture design involving teeth and implants as an alternative to unsuccessful fixed implant therapy: a case report. Implant Dent 2004;13:218-22. https://doi.org/10.1097/01.id.0000136919.13387.94
- Park JM, Koak JY, Kim SK, Joo JH, Heo SJ. Consideration for the combination treatment of removable partial denture and implant. Implantol 2015;19:104-11.
- Trakas T, Michalakis K, Kang K, Hirayama H. Attachment systems for implant retained overdentures: a literature review. Implant Dent 2006;15:24-34. https://doi.org/10.1097/01.id.0000202419.21665.36
- Zitzmann NU, Marinello CP. Treatment plan for restoring the edentulous maxilla with implant-supported restorations: removable overdenture versus fixed partial denture design. J Prosthet Dent 1999;82:188-96. https://doi.org/10.1016/S0022-3913(99)70155-1
- van Kampen F, Cune M, van der Bilt A, Bosman F. Retention and postinsertion maintenance of bar-clip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3 months of function. Clin Oral Implants Res 2003;14:720-6. https://doi.org/10.1046/j.0905-7161.2003.00961.x
- Kim MS, Yoon MJ, Huh JB, Jeon YC, Jeong CM. Implant overdenture using a locator bar system by drill and tapping technique in a mandible edentulous patient: a case report. J Adv Prosthodont 2012;4:116-20. https://doi.org/10.4047/jap.2012.4.2.116
- Walton JN, MacEntee MI, Glick N. One-year prosthetic outcomes with implant overdentures: a randomized clinical trial. Int J Oral Maxillofac Implants 2002;17:391-8.
- Misch CE, Goodacre CJ, Finley JM, Misch CM, Marinbach M, Dabrowsky T, English CE, Kois JC, Cronin RJ Jr. Consensus conference panel report: crown-height space guidelines for implant dentistry-part 2. Implant Dent 2006;15:113-21. https://doi.org/10.1097/01.id.0000217907.18396.18
- Bulaqi HA, Mousavi Mashhadi M, Safari H, Samandari MM, Geramipanah F. Effect of increased crown height on stress distribution in short dental implant components and their surrounding bone: A finite element analysis. J Prosthet Dent 2015;113:548-57. https://doi.org/10.1016/j.prosdent.2014.11.007
- Bortolini S, Natali A, Franchi M, Coggiola A, Consolo U. Implant-retained removable partial dentures: an 8-year retrospective study. J Prosthodont 2011;20:168-72. https://doi.org/10.1111/j.1532-849X.2011.00700.x
- Chikunov I, Doan P, Vahidi F. Implant-retained partial overdenture with resilient attachments. J Prosthodont 2008;17:141-8. https://doi.org/10.1111/j.1532-849X.2007.00261.x
- Krennmair G, Krainhofner M, Piehslinger E. Implantsupported mandibular overdentures retained with a milled bar: a retrospective study. Int J Oral Maxillofac Implants 2007;22:987-94.
- Zarb GA, Bolender CL, Eckert SE, Fenton AH, Jacob RF, Mericske-Stern R. Prosthodontic treatment for edentulous patients : complete dentures and implant-supported prostheses. 12th ed. St. Louis: Mosby; 2004.
- Schneider AL, Kurtzman GM. Bar overdentures utilizing the Locator attachment. Gen Dent 2001;49:210-4.
- Cha MS, Kim DG, Park CJ, Cho LR. A literature review on locator attachment for implant overdenture. J Dent Rehabil Appl Sci 2013;29:127-40. https://doi.org/10.14368/jdras.2013.29.2.127