참고문헌
- Yousef H, Luke A, Ricci J, Weiner S. Analysis of changes in implant screws subject to occlusal loading: a preliminary analysis. Implant Dent 2005;14:378-82. https://doi.org/10.1097/01.id.0000187902.68436.e4
- Bickford JH. An introduction to the design and behavior of bolted joints. Marcel Decker: Inc.; 1995.
- Binon PP, Binon P. The external hexagonal interface and screw-joint stability: A primer on threaded fasteners in implant dentistry. Quint Dent Technol 2000;23:91-104.
- Jorge JR, Barao VA, Delben JA, Assuncao WG. The role of implant/abutment system on torque maintenance of retention screws and vertical misfit of implant-supported crowns before and after mechanical cycling. Int J Oral Maxillofac Implants 2013;28:415-22. https://doi.org/10.11607/jomi.2727
- Michalakis KX, Calvani PL, Muftu S, Pissiotis A, Hirayama H. The effect of different implant-abutment connections on screw joint stability. J Oral Implantol 2014;40:146-52. https://doi.org/10.1563/AAID-JOI-D-11-00032
- Sesma N, Pannuti C, Cardaropoli G. Retrospective clinical study of 988 dual acid-etched implants placed in grafted and native bone for single-tooth replacement. Int J Oral Maxillofac Implants 2012;27:1243-8.
- Breeding LC, Dixon DL, Nelson EW, Tietge JD. Torque required to loosen single-tooth implant abutment screws before and after simulated function. Int J Prosthodont 1993;6:435-9.
- Jorn D, Kohorst P, Besdo S, Rucker M, Stiesch M, Borchers L. Influence of lubricant on screw preload and stresses in a finite element model for a dental implant. J Prosthet Dent 2014;112:340-8. https://doi.org/10.1016/j.prosdent.2013.10.016
- Martin WC, Woody RD, Miller BH, Miller AW. Implant abutment screw rotations and preloads for four different screw materials and surfaces. J Prosthet Dent 2001;86:24-32. https://doi.org/10.1067/mpr.2001.116230
- Lang LA, May KB, Wang RF. The effect of the use of a counter-torque device on the abutment-implant complex. J Prosthet Dent 1999;81:411-7. https://doi.org/10.1016/S0022-3913(99)80007-9
- Theoharidou A, Petridis HP, Tzannas K, Garefis P. Abutment screw loosening in single-implant restorations: a systematic review. Int J Oral Maxillofac Implants 2008;23:681-90.
- Persson LG, Lekholm U, Leonhardt A, Dahlen G, Lindhe J. Bacterial colonization on internal surfaces of Branemark system implant components. Clin Oral Implants Res 1996;7:90-5. https://doi.org/10.1034/j.1600-0501.1996.070201.x
- Piattelli A, Vrespa G, Petrone G, Iezzi G, Annibali S, Scarano A. Role of the microgap between implant and abutment: a retrospective histologic evaluation in monkeys. J Periodontol 2003;74:346-52. https://doi.org/10.1902/jop.2003.74.3.346
- Seloto CB, Strazzi Sahyon HB, Dos Santos PH, Delben JA, Assuncao WG. Efficacy of sealing agents on preload maintenance of screw-retained implant-supported prostheses. Int J Oral Maxillofac Implants 2018;33:123-6. https://doi.org/10.11607/jomi.5576
- Ozdiler A, Bakir-Topcuoglu N, Kulekci G, Isik-Ozkol G. Effects of taper angle and sealant agents on bacterial leakage along the implant-abutment interface: An in vitro study under loaded conditions. Int J Oral Maxillofac Implants 2018;33:1071-7. https://doi.org/10.11607/jomi.6257
- Mathias CG, Maibach HI. Allergic contact dermatitis from anaerobic acrylic sealants. Arch Dermatol 1984;120:1202-5. https://doi.org/10.1001/archderm.1984.01650450084025
- Henkel. Loctite 243 Technical Data Sheet and Safety Data Sheet. 2019;007.1. Available at: https://www.henkel-adhesives. com/kr/ko/product/threadlockers/loctite_243.html
- Burguete RL, Johns RB, King T, Patterson EA. Tightening characteristics for screwed joints in osseointegrated dental implants. J Prosthet Dent 1994;71:592-9. https://doi.org/10.1016/0022-3913(94)90443-X
- Gubisch M, Liu Y, Spiess L, Romanus H, Krischok S, Ecke G, Schaefer JA, Knedlik Ch. Nanoscale multilayer WC/C coatings developed for nanopositioning: Part I. Microstructures and mechanical properties. Thin Solid Films 2005;488:132-9. https://doi.org/10.1016/j.tsf.2005.04.107
- Choi JU, Jeong CM, Jeon YC, Lim JS, Jeong HC. Influence of tungsten carbide/carbon coating on the preload of implant abutment screws. J Korean Acad Prosthodont 2006;44:229-42.
- Yoon KJ, Park YB, Choi H, Cho Y, Lee JH, Lee KW. Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant. J Adv Prosthodont 2016;8:465-471. https://doi.org/10.4047/jap.2016.8.6.465
- Haack JE, Sakaguchi RL, Sun T, Coffey JP. Elongation and preload stress in dental implant abutment screws. Int J Oral Maxillofac Implants 1995;10:529-36.
- McGlumphy EA, Mendel DA, Holloway JA. Implant screw mechanics. Dent Clin North Am 1998;42:71-89.
- Piermatti J, Yousef H, Luke A, Mahevich R, Weiner S. An in vitro analysis of implant screw torque loss with external hex and internal connection implant systems. Implant Dent 2006;15:427-35. https://doi.org/10.1097/01.id.0000245440.09464.48
- Siamos G, Winkler S, Boberick KG. Relationship between implant preload and screw loosening on implant-supported prostheses. J Oral Implantol 2002;28:67-73. https://doi.org/10.1563/1548-1336(2002)028<0067:TRBIPA>2.3.CO;2
- Shigley JE. Mechanical engineering design. 3rd ed. New York: McGraw Hill; 1985.
- Motosh N. Development of design charts for bolts preloaded up to the plastic range. J Eng Ind Aug 1976;98:849-51. https://doi.org/10.1115/1.3439041
- Assuncao WG, Delben JA, Tabata LF, Barao VA, Gomes EA, Garcia IR Jr. Preload evaluation of different screws in external hexagon joint. Implant Dent 2012;21:46-50. https://doi.org/10.1097/ID.0b013e31823fcbce
- Assuncao WG, Barao VA, Delben JA, Gomes EA, Garcia IR Jr. Effect of unilateral misfit on preload of retention screws of implant-supported prostheses submitted to mechanical cycling. J Prosthodont Res 2011;55:12-8. https://doi.org/10.1016/j.jpor.2010.05.002
- Delben JA, Barao VA, Dos Santos PH, Assuncao WG. Influence of abutment type and esthetic veneering on preload maintenance of abutment screw of implant-supported crowns. J Prosthodont 2014;23:134-9. https://doi.org/10.1111/jopr.12065
- Sakaguchi RL, Borgersen SE. Nonlinear finite element contact analysis of dental implant components. Int J Oral Maxillofac Implants 1993;8:655-61.
- Steinebrunner L, Wolfart S, Ludwig K, Kern M. Implantabutment interface design affects fatigue and fracture strength of implants. Clin Oral Implants Res 2008;19:1276-84. https://doi.org/10.1111/j.1600-0501.2008.01581.x
- MIL-S-46163A. Compounds: Thread-locking, anaerobic, Single-component. US-defense standard. 1974. Available at: http://everyspec.com/MIL-SPECS/MIL-SPECS-MIL-S/MILS-46163A_16063/
- Ham YU, Jo KH, Jeon HH, Kim SI. Design and analysis of optimum application of thread-locker. Korean Soc Precision Eng 2017;5:343-4.
- Broggini N, McManus LM, Hermann JS, Medina RU, Oates TW, Schenk RK, Buser D, Mellonig JT, Cochran DL. Persistent acute inflammation at the implant-abutment interface. J Dent Res 2003;82:232-7. https://doi.org/10.1177/154405910308200316