DOI QR코드

DOI QR Code

A Study on the Reliability Assesment of Solar Photovoltaic and Thermal Collector System

태양광열 시스템의 신뢰성 평가에 관한 연구

  • Park, Tae-Kook (Nuclear Equipment Qualification & Safety Research Group, Korea Institute of Machinery and Materials) ;
  • Bae, Seung-Hoon (Nuclear Equipment Qualification & Safety Research Group, Korea Institute of Machinery and Materials) ;
  • Kim, Sang-Kyo (Nuclear Equipment Qualification & Safety Research Group, Korea Institute of Machinery and Materials) ;
  • Kim, Seon-Min (Nuclear Equipment Qualification & Safety Research Group, Korea Institute of Machinery and Materials) ;
  • Kim, Dae-Hwan (Nuclear Equipment Qualification & Safety Research Group, Korea Institute of Machinery and Materials) ;
  • Eom, Hak-Yong (Department of Reliability Assessment, Korea Institute of Machinery and Materials) ;
  • Lee, Keun-Hui (Janghan Engineers Inc.)
  • Received : 2020.09.08
  • Accepted : 2020.11.18
  • Published : 2020.12.25

Abstract

Photovoltaic and Thermal collector (PV/T) systems are renewable energy devices that can produce electricity and heat energy simultaneously using solar panels and heat exchangers. Since PV/T systems are exposed to the outdoors, their reliability is affected by various environmental factors. This paper presents a reliability test for a PV/T system and evaluates the test results. The reliability assessment entails performance, environment, safety, and life tests. The factor that had the greatest influence on the life of the system was the hydraulic pressure applied to the heat exchanger. A test was conducted by repeatedly applying pressure to the PV/T system, and a reliability analysis was conducted based on the test results. As a result, the shape parameter (β) value of 5.6658 and the B10life 308,577 cycles at the lower 95% confidence interval were obtained.

Keywords

References

  1. Tripanagnostopoulos, Y., Nousia, T.H., Souliotis, M., and Yianoulis P., 2002, "Hybrid photovoltaic/thermal solar Systems", Solar Energy, 72(3), 217-234. https://doi.org/10.1016/S0038-092X(01)00096-2
  2. Kim, J.H. and Kim, J.T., 2007, "The performance comparison of PVT system through literature review", Journal of Korean Institute of Architectural Sustainable Environment and Building Systems, 1(2), 15-21.
  3. Euh, S.H., Lee, J.B., Choi, Y.S., and Kim, D.H., 2012, "The performance and efficiency analysis of a PVT system compared with a PV module and a solar collector", J. Korean Solar Energy, 32(2), 1-10.
  4. Park, T.K., Kim, D.H., Kim, J.H., Lee, K.C., Chang, M.S., Lee, K.C., and Choi, Y.D., 2019, "Experimental study to predict the performance of solar photovoltaic and thermal collector panels", New. Renew. Energy, 15(2), 42-51. https://doi.org/10.7849/ksnre.2019.6.15.2.042
  5. Fan, J., Seng, T.P., Hua, G.L., On, L.K., and Loh K., 2016, "Design and thermal performance test of a solar photovoltaic/thermal (PV/T) collector", Journal of Clean Energy Technologies, 4(6), 435-439. https://doi.org/10.18178/JOCET.2016.4.6.327
  6. Kim, Y.H. and Shim, K.S., 2013, "Efficiency computation and failure detection of solar power generation panels", Journal of KIISE : Computer Systems and Theory, 40(1), 1-7.
  7. Chow, T.T., He, W., and Ji, J., 2006, "Hybrid photovoltaic-thermosyphon water heating system for residential application", Solar Energy, 80(3), 298-306. https://doi.org/10.1016/j.solener.2005.02.003
  8. Lee, K.S., Lee, E.J., and Kang E.C., 2016, "Experimental study on the PVT inlet water temperature dependant power efficiency characteristics", New. Renew. Energy, 12(3), 31-35. https://doi.org/10.7849/ksnre.2016.9.12.3.31
  9. Kim, S.M., Kim, J.H., and Kim, J.T., 2019, "An experimental study on thermal and electrical performance of an air-type PVT collector", J. Korean Solar Energy, 39(2), 23-32. https://doi.org/10.7836/kses.2019.39.2.023
  10. Her, E.J., Bae, S.M., Kim, J.M., and Nam, Y.J., 2019, "Feasibility analysis based on energy simulation of PVT hot water system", Korean J. Air-Cond. Refrig. Eng., 31(7), 312-321.
  11. Yu, J.S., Kim, J.H., and Kim, J.T., 2019, "A study for improving thermal performance according to variables of perforated baffle in air-type PVT collector", J. Korean Solar Energy, 39(6), 83-91. https://doi.org/10.7836/kses.2019.39.6.083
  12. ISO 9806, 2017, "Solar energy - Solar thermal collectors - Test methods", International organization for standardization.
  13. IEC 61215, 2005, "Crystalline silicon terrestrial photovoltaic (PV) modules - Design qualification and type approval", International Electrotechnical Commission.
  14. KORAS, 2018, "PV/T composite panel", RS-KORAS-KIMM-260. https://rac.kimm.re.kr/html/info/info03_01.php
  15. Chang, M.S., Park, T.K., Sung, B.J., and Choi, B.O., 2015, "Life prediction of brazed plate heat exchanger based on several accelerated life test data", J. Mech. Sci. Technol., 29(6), 2341-2348. https://doi.org/10.1007/s12206-015-0526-y
  16. Kim, S.I., Park, M.Y., and Park, J.W., 2010, "A comparison of estimation methods for Weibull distribution and type I censoring", J. Korean Soc. Qual. Manag., 38(4), 480-490.
  17. Bertsche, B., 2008, "Reliability in automotive and mechanical engineering", Springer.
  18. Elsayed, A.E., 2012, "Reliability Engineering", 2nd ed., WILEY.