DOI QR코드

DOI QR Code

Experimental and numerical investigation of wire rope devices in base isolation systems

  • Calabrese, Andrea (Dept. of Civil Engineering & Construction Engineering Management, California State Univ. Long Beach) ;
  • Spizzuoco, Mariacristina (Department of Structures for Engineering and Architecture, University of Naples Federico II) ;
  • Losanno, Daniele (Department of Structures for Engineering and Architecture, University of Naples Federico II) ;
  • Barjani, Arman (Dept. of Civil Engineering & Construction Engineering Management, California State Univ. Long Beach)
  • Received : 2019.01.30
  • Accepted : 2020.01.04
  • Published : 2020.03.25

Abstract

The scope of this study is the comparison between experimental results of tests performed on a base isolated building using helical wire rope isolators (WRs), and results of Nonlinear Response History Analyses (NRHAs) performed using SAP 2000, a commercial software for structural analysis. In the first stage of this research, WRs have been tested under shear deformation beyond their linear range of deformation, and analytical models have been derived to describe the nonlinear response of the bearings under different directions of loading. On the following stage, shaking table tests have been carried out on a 1/3 scale steel model isolated at the base by means of curved surface sliders (CSS) and WRs. The response of the structure under ground motion excitation has been compared to that obtained using numerical analyses in SAP 2000. The feasibility of modelling the nonlinear behavior of the tested isolation layer using multilinear link elements embedded in SAP 2000 is discussed in this paper, together with the advantages of using WRs as supplemental devices for CSSs base isolated structures.

Keywords

Acknowledgement

The authors would like to acknowledge the support of the Italian Department of Civil Protection (P.E. 2010-2013 - Task 2.3.2 - Development of new technologies for seismic mitigation). They are also grateful for the support provided by Powerflex S.r.l., Limatola (BN), supplier of the wirerope devices discussed in this study.

References

  1. Ambraseys, N., Smit, P., Sigbjornsson, R., Suhadolc, P. and Margaris, B. (2002), "Internet-Site for European Strong-Motion Data", European Commission, Research-Directorate General, Environment and Climate Program 2002, http://www.isesd.hi.is/ESD_Local/frameset.htm [24 July 2013].
  2. Belluzzi, O. (1966), Science of the Constructions, Zanichelli, Bologna, Italy.
  3. Calabrese, A., Spizzuoco, M., Serino, G., Della Corte, G. and Maddaloni, G. (2015), "Shake table investigation of a novel, low-cost, base isolation technology using recycled rubber", Struct. Health Monit., 22(1), 107-122, http://:10.1002/stc.1663.NTC.
  4. Cardone, D., Gesualdi, G. and Brancato, P. (2015), "Restoring capability of friction pendulum seismic isolation systems", Bull. Earthq. Eng., http://10.1007/s10518-014-9719-5.
  5. Chopra, A.K. (2007), Dynamics of Structures: Theory and applications to earthquake engineering, Prentice-Hall, Englewood Cliffs, N.J. U.S.A.
  6. Costello, G.A. (1990), Theory of Wire Rope, (4th Edition), Springer Verlag, New York. U.S.A.
  7. Cutchins, M.A., Cochran, J.E., Kumar, K., Fitz-Coy, N.G. and Tinker, M.L. (1987), Initial investigations into the damping characteristics of wire rope vibration isolators, Final Technical Report prepared under NASA Research Grant NAG8-532, Engineering Experiment Station, Auburn University, Alabama.
  8. Demetriades, G.F., Costantinou, M.C. and Reinhorn, A.M. (1993), "Study of wire rope systems for seismic protection of equipment in buildings", Eng. Struct., 15(5), 321-334. https://doi.org/10.1016/0141-0296(93)90036-4.
  9. Den Hartog, J.P. (1961), Strength of Materials, Dover Publications Inc, New York. U.S.A.
  10. Di Donna, M. and Serino, G. (2002), "Base isolation of high-voltage equipment: comparison between two different solutions", Proc. of the 7th International Conference on Probabilistic Methods Applied to Power Systems, Napoli, Italy.
  11. Dolce, M., Cardone, D. and Croatto, F. (2005), "Frictional behavior of steel-PTFE interfaces for seismic isolation", Bull. Earthq. Eng., 3(1), 75-99. https://doi.org/10.1007/s10518-005-0187-9.
  12. Gesualdo, F.A.R. and Lima, M.C.V. (2012), "An initial investigation of the inverted trussed beam formed by wooden rectangular cross section enlaced with wire rope", Struct. Eng. Mech., 44(2), 239-255, http://dx.doi.org/10.12989/sem.2012.44.2.239.
  13. Ghalandari, A., Ghasemi, M.R. and Dizangian, B. (2018), "Enhancing seismic performance of ductile moment frames with delayed wire-rope bracing using middle steel plate", Steel Compos. Struct., 28(2), 139-147, http://dx.doi.org/10.12989/scs.2018.28.2.139.
  14. Giannini, R., Alessandri, S., Paolacci, F. and Malena, M. (2015), "Seismic retrofitting of a HV circuit breaker through base isolation with steel cable dampers. Part 1: Preliminary tests and analyses", Eng. Struct., http://10.1016/j.engstruct.2015.03.032.
  15. Housner, G.W. (1975), "Measures of severity of earthquake ground shaking", Proceedings of the U.S. National Conference on Earthquake Engineering, Ann Arbor, Miami. U.S.A.
  16. Hussaini, T.M., Zayas, V.A. and Constantinou, M.C. (1994), Seismic isolation of a multi-story frame structure using spherical sliding isolation systems, Technical Report No. NCEER-94-0007, National Center for Earthquake Engineering Research, Buffalo, N.Y. U.S.A.
  17. Iervolino, I., Galasso, C. and Cosenza, E. (2010), "REXEL: computer aided record selection for code - based seismic structural analysis", Bull. Earthq. Eng., 8(2), 399-362, https://doi.org/10.1007/s10518-009-9146-1.
  18. Ismail, M., Rodellar, J. and Pozo, F. (2016), "An isolation device for near-fault ground motions", Struct. Health Monit., 21(3), 249-268. https://doi.org/10.1002/stc.1549.
  19. Katsaras, C.P., Panagiotakos, T.B. and Kolias, B. (2008), "Restoring capability of bilinear hysteretic seismic isolation system", Earthq. Eng. Struct. Dyn., 37(4), 557-575. https://doi.org/10.1002/eqe.772.
  20. Liossatou, E. and Fardis, M.N. (2016), "Near-fault effects on residual displacements of RC structures", Earthq. Eng. Struct. Dyn., 45(9), 1391-1409, https://doi.org/10.1002/eqe.2712.
  21. Love, A.E.H. (1927), A Treatise on the Mathematical Theory of Elasticity, Dover Publications, New York. U.S.A.
  22. Nuove norme tecniche per le costruzioni. DM 17 gennaio 2018, Circolare 21 gennaio 2019 n. 7 C.S.LL.PP., Gazzetta Ufficiale n. 42 del 29 febbraio 2018 - Supplemento Ordinario n. 30. http://www.cslp.it/cslp/index.php?option=com_docman&task=doc_download&gid=3269&Itemid=10 [24 July 2013] (in Italian).
  23. Powell, G.H. (2010), Modeling for structural analysis: behavior and basics, Computers and Structures, Inc., Berkeley, California, U.S.A.
  24. Quaglini, V., Dubini, P. and Poggi, C. (2012), "Experimental assessment of sliding materials for seismic isolation systems", Bull. Earthq. Eng., 10(2), 717-740. https://doi.org/10.1007/s10518-011-9308-9.
  25. Quaglini, V., Gandelli, E. and Dubini, P. (2017), "Experimental investigation of the recentring capability of curved surface sliders", Struct. Health Monit., 24(2), e1870, https://doi.org/10.1002/stc.1870.
  26. Serino, G., Bonacina, G. and Bettinali, F. (1995), "Passive protection devices for high-voltage equipment: design procedures and performance evaluation", Proceedings. of the 4th US Conference Sponsored by the ASCE Technical Council on Lifeline Earthquake Engineering, San Francisco, California,
  27. Spizzuoco, M., Quaglini, V., Calabrese, A., Serino, G. and Zambrano, C. (2017), "Study of wire rope devices for improving the re-centering capability of base isolated buildings", Struct. Health Monit., 24(6), 1-16. https://doi.org/10.1002/stc.1928.
  28. Vaiana, N., Spizzuoco, M. and Serino, G. (2017a), "Wire rope isolators for seismically base-isolated lightweight structures: experimental characterization and mathematical modeling", Eng. Struct., 140, 498-514, http://dx.doi.org/10.1016/j.engstruct.2017.02.057.
  29. Vaiana, N., Spizzuoco, M. and Serino, G. (2017b), "A parallel model for predicting the horizontal dynamic behavior of helical wire rope isolators", Int. J. Civil Struct. Eng., 4(1), 63-68, ISSN 2372-3971.
  30. Yurdakul, M. and Ates, S. (2011), "Modeling of triple concave friction pendulum bearings for seismic isolation of buildings", Struct. Eng. Mech., 40(3), https://doi.org/10.12989/sem.2011.40.3.315.

Cited by

  1. Early adjusting damping force for sloped rolling-type seismic isolators based on earthquake early warning information vol.20, pp.1, 2020, https://doi.org/10.12989/eas.2021.20.1.039