DOI QR코드

DOI QR Code

A Study on Abdomen MRI Scan Using Metronome

메트로놈을 이용한 복부 MRI 검사에 대한 연구

  • Received : 2020.08.22
  • Accepted : 2020.08.30
  • Published : 2020.09.30

Abstract

MRI scans in the abdominal area are difficult to achieve optimal images due to artificial respiration. Among 45 patients (male:female = 30:15) who underwent abdominal MRI examination, a metronome-based examination method was studied for patients whose breathing is difficult and difficult to examine. The images examined without using a metronome were divided into group A, and the images examined using a metronome were divided into group B. Image quality improvement (30%) and inspection time (approximately 50 seconds) were reduced in images using metronome. During abdominal magnetic resonance imaging (ABD MRI), the images examined using a metronome had differences in quality and examination time compared to the unused images. It is more effective to use a metronome brace that controls the patient's respiratory rate during abdominal magnetic resonance imaging under respiratory induction in patients with difficulty in respiratory-gated.

복부 분야 MRI 검사는 호흡에 의한 인공물로 인해 최적의 영상 구현이 어렵다. 복부 MRI 검사를 받은 총 45명 (남자:여자 = 30:15) 중 호흡이 일정하지 않아 검사가 어려운 환자를 대상으로 메트로놈을 이용한 검사 방법에 대하여 연구 하였다. 메트로놈을 사용하지 않고 검사 한 영상을 A 그룹, 메트로놈을 사용하여 검사 한 영상을 B그룹으로 나누었다. 메트로놈을 사용한 영상에서 화질 향상이 약 30% 증대 되었고, 검사시간이 약 50초 감소되었다. 복부자기공명영상(ABD MRI) 검사 시 메트로놈(Metronome)을 사용하여 검사 한 영상이 사용하지 않은 영상에 비하여 화질과 검사시간 차이가 있었다. 호흡동조가 어려운 환자의 호흡 유도 하(RTr Scan) 복부 자기 공명 영상(Abdomen MRI) 검사 시 환자의 호흡수를 조절하는 메트로놈 (Metronome) 보조기를 사용하면 더 효과적이다.

Keywords

References

  1. K. Burnand, G. Barone, K. McHugh, and K. Cross, "Preoperative computed tomography scanning for abdominal neuroblastomas is superior to magnetic resonance imaging for safe surgical planning," National Center for Biotechnology Information, vol. 46, no. 12, pp. 1684-1693, Jul. 2016. doi: 10.1002/pbc.27955. Epub 2019 Aug. 8.
  2. C. Zhu, H. Haraldsson, F. Faraji, C. Owens, W. Gasper, S. Ahn , J. Liu, G. Laub, M.D. Hope, and D. Saloner, "Isotropic 3D black blood MRI of abdominal aortic aneurysm wall and intraluminal thrombus," International Digital Publishing, vol. 34 no. 1, pp. 18-25, Jan. 2016. doi: 10.1016/j.mri.2015.10.002.IDPF 2015 Oct. 22.
  3. S. J. Cha, "Effect of bowel movement inhibitors in abdominal magnetic resonance imaging: A comparative study of conventional cinematographers," Ph. D. dissertation, Inje university, 1993.
  4. Liver magnetic resonance imaging (source of medical information from Seoul National University Hospital [Internet]. Available: http://terms.naver.com/entry.nhn?docId=927622&cid=51007&categoryId=51007. 2020.
  5. S. S. Korreman, "Image-guided radiotherapy and motion management in lung cancer", The British Institute of Radiology, vol. 88, pp. 11-12, May. 2015.
  6. A. M. Tinga, N. Ivan, P. J. Michel, T. T. deBack, and M. M. Louwerse, "Respiratory biofeedback does not facilitate lowering arousal in meditation through virtual reality," Ph. D. dissertation, Tilburg University, pp. 51-59, Mar. 2019.
  7. M. J. Kim, I. C. Im, J. S. Lee, and S.M. Kang, "The Optimum of Respiratory Phase Using the Motion Range of the Diaphragm: Focus on Respiratory Gated Radiotherapy of Lung Cancer," Journal of the Korean Society of Radiology, vol. 7, no. 2, pp. 157-163, ISSN 1976-0620, Apr. 2013. https://doi.org/10.7742/jksr.2013.7.2.157
  8. H. S. Park, and D. G. Kang, "A Study on abdominal magnetic resonance imaging using metronome," Journal of the Korean Society of MR Technology, vol. 28, no. 2, pp. 11-17, Sep. 2018. https://doi.org/10.31159/ksmrt.2018.28.2.11