총의치 제작에 적용 가능한 디지털 기술과 임상적 고찰

Application and consideration of digital technology for removable complete denture

  • 이정진 (전북대학교 치과대학 치과보철학교실) ;
  • 송광엽 (전북대학교 치과대학 치과보철학교실) ;
  • 박주미 (전북대학교 치과대학 치과보철학교실)
  • Lee, Jung-Jin (Department of Prosthodontics, School of Dentistry, Chonbuk National University) ;
  • Song, Kwang-Yeob (Department of Prosthodontics, School of Dentistry, Chonbuk National University) ;
  • Park, Ju-Mi (Department of Prosthodontics, School of Dentistry, Chonbuk National University)
  • 발행 : 2019.08.31

초록

Digital technology has changed various aspects of the clinical dentistry. The intraoral scanner and Computer-aided design / Computer-aided manufacturing (CAD-CAM) technology are widely used in fabricating fixed prostheses and in implant surgery. These technologies greatly improved the efficiency of clinical and laboratory procedures. With all newly introduced software, devices, and clinical studies, digital technology has been actively applied in removable prostheses. It is now possible to fabricate the removable prostheses more quickly and easily through subtractive and additive manufacturing. Various clinical and laboratory protocols were introduced by many manufacturers. The purpose of this review is to summarize the literature on digital technology for fabricating complete denture with current status and future perspectives.

키워드

참고문헌

  1. Cunha TR, Vecchia Della MP, Regis RR, et al. A randomised trial on simplified and conventional methods for complete denture fabrication: Masticatory performance and ability. J Dent 2013;41:133-42. https://doi.org/10.1016/j.jdent.2012.09.008
  2. Maeda Y, Minoura M, Tsutsumi S, Okada M, Nokubi T. A CAD/CAM system for removable denture. Part I: Fabrication of complete dentures. Int J Prosthodont 1994;7:17-21.
  3. Yuzbasioglu E, Kurt H, Turunc R, Bilir H. Comparison of digital and conventional impression techniques: evaluation of patients' perception, treatment comfort, effectiveness and clinical outcomes. BMC Oral Health 2014;14:10. https://doi.org/10.1186/1472-6831-14-10
  4. Yoon HI, Lee SM, Park EJ. Comparison of patient satisfaction with digital and conventional impression for prosthodontic treatment. J Korean Acad Prosthodont 2016;54:379-86. https://doi.org/10.4047/jkap.2016.54.4.379
  5. Lee JH. Improved digital impressions of edentulous areas. J Prosthet Dent 2017;117:448-9. https://doi.org/10.1016/j.prosdent.2016.08.019
  6. Fang JH, An X, Jeong SM, Choi BH. Digital intraoral scanning technique for edentulous jaws. J Prosthet Dent 2018;119:733?5. https://doi.org/10.1016/j.prosdent.2017.05.008
  7. Fang JH, An X, Jeong SM, Choi BH. Development of complete dentures based on digital intraoral impressions?Case report. J Prosthodont Res 2018;62:116-20. https://doi.org/10.1016/j.jpor.2017.05.005
  8. Hong SJ, Lee H, Paek J, et al. Combining Conventional Impressions and Intraoral Scans: A Technique for the Treatment of Complete Denture Patients with Flabby Tissue. J Prosthodont 2019 [Epub ahead of print].
  9. Russo Lo L, Ciavarella D, Salamini A, Guida L. Alignment of intraoral scans and registration of maxillo-mandibular relationships for the edentulous maxillary arch. J Prosthet Dent 2019 [Epub ahead of print].
  10. Baba NZ, AlRumaih HS, Goodacre BJ, Goodacre CJ. Current techniques in CAD/CAM denture fabrication. Gen Dent 2016;64:23-8.
  11. AlHelal A, AlRumaih HS, Kattadiyil MT, Baba NZ, Goodacre CJ. Comparison of retention between maxillary milled and conventional denture bases: A clinical study. J Prosthet Dent 2017;117:233-8. https://doi.org/10.1016/j.prosdent.2016.08.007
  12. Steinmassl O, Dumfahrt H, Grunert I, Steinmassl P-A. CAD/CAM produces dentures with improved fit. Clin Oral Investig 2018;22:2829-35. https://doi.org/10.1007/s00784-018-2369-2