DOI QR코드

DOI QR Code

Temperature Variation Corresponding to the Protection Method and Edge Distance in Near-Surface-Mounted FRP in Concrete with Fire Protection

콘크리트내 표면매립보강된 FRP의 내화단열방법과 연단거리에 따른 온도변화

  • Received : 2019.09.23
  • Accepted : 2019.11.01
  • Published : 2019.11.30

Abstract

Recently, the Near-Surface-Mounting method using Fiber reinforced polymer (FRP) has been developed and applied to the reinforcement of many concrete structural members. However, as a part of the fire resistance design, there is a lack of research related to fire insulation for the areas reinforced with FRP. In case of NSM reinforcement, there is a difference in the transferred temperature from the external surface to the groove corresponding to the location of the groove where the FRP is embedded, and the effect of this should be reflected in the fireproof insulation design. Therefore, in this study, after forming grooves for surface embedding in concrete blocks, fireproof insulation reinforcement was performed using Calcium Silicate (CS) fireproof board and an experiment to evaluate the temperature transfer was performed. By observing the temperature at these groove positions, the reduction of temperature transfer according to fireproof insulation detail was studied. As a result, when the NSM-FRP is properly fire-insulated using the CS-based fireproof board, the epoxy inside the groove does not reach its glass transition temperature until the external temperature reaches $800^{\circ}C$.

Keywords

Acknowledgement

Supported by : 국토교통부

References

  1. Blontrock, H., Taerwe, L., & Vandevelde, P. (2001). Fire testing of concrete slabs strengthened with fibre composite laminates, Proceeding of 5th International Conference on Fibre Reinforced Plastics for Reinforced Concrete Structures, Telford, Cambridge, U.K., 547.556.
  2. Kim, H., Seo, C., & Shin, H. (2005). An experimental study on the mechanical properties by compressive strength areas at high temperature, Journal of Architectural Institute of Korea, 21(7), 55-66.
  3. Lim, J., Seo, S., & Song, S. (2017). Experiment for the Improvement of Fire Resistance Capacity of Reinforced Concrete Flexural Member Strengthened with Carbon Fiber Reinforced Polymer, Journal of the Architectural Institute of Korea, Structure & Construction, 33(12), 19-27. https://doi.org/10.5659/JAIK_SC.2017.33.1.19
  4. Lim, J., & Seo, S. (2018). Fire-Protection Method to Improve the Fire-Resistance Capacity of Near-Surface-Mounted Fiber Reinforced Polymer, Journal of the Regional Association of Architectural Institute of Korea, 20(1), 141-148.
  5. Palmieri, A., Matthys, S., & Taerwe, L. (2011). Bond behavior of NSM FRP bars at elevated temperatures, Proceeding of First Middle East Conference on Smart Monitoring, Assessment and Rehabilitation Civil Structures. 1-7
  6. Palmieri, A., Matthys, S., & Taerwe, L. (2013). Fire Endurance and Residual Strength of Insulated Concrete Beams Strengthened with Near-Surface Mounted Reinforcement. J. of Compos. Constr. 17(4), 454-462. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000338
  7. Seo, S., Oh, J., & Choi, K. (2011). Bond Capacity of Concrete Member Strengthened by Various Methods Using FRP Plate, Journal of the Architectural Institute of Korea, Structure & Construction, 27(8), 55-63.
  8. Seo, S. (2012a). Bond Strength of Near Surface-Mounted FRP Plate in RC Member, Journal of the Korea Concrete Institute, 24(4), 415-422. https://doi.org/10.4334/JKCI.2012.24.4.415
  9. Seo, S., Choi, G., & Kwon, Y. (2012b). Retrofit capacity of near-surface-mounted RC beam by using FRP Plate, Journal of The Korea Institute for Structural maintenance and Inspection, 16(1). 18-26. https://doi.org/10.11112/jksmi.2012.16.1.018
  10. Seo, S., Feo, L., & Hui, D. (2013a). Bond Strength of Near-Surface-Mounted FRP Plate for Retrofit of Concrete Structures, Composite Structures, 95, 719-727. https://doi.org/10.1016/j.compstruct.2012.08.038
  11. Seo, S., & Kim, J. (2013b). Bond capacity of nearsurface-mounted CFRP plate to concrete under various temperatures, Journal of the Korea Institute for Structural Maintenance and Inspection, 17(4), pp.75-83. https://doi.org/10.11112/jksmi.2013.17.4.075
  12. Seo, S., & Kim, M. (2013c). Bond Strength of Near Surface-Mounted FRP Plate in Concrete Corresponding to Space and Bond Length, Journal of the Korea Concrete Institute, 25(1), 37-43. https://doi.org/10.4334/JKCI.2013.25.1.037
  13. Seo, S. (2014). Analysis on the Interfacial Bond-Slip Relationship between Near Surface-Mounted FRP Plate and Concrete, Journal of the Korea Concrete Institute, 26(1), 79-86. https://doi.org/10.4334/JKCI.2014.26.1.079
  14. Seo, S. (2016a). Effect of Shear Key and Edge Length of Near Surface-Mounted FRP Plate in Concrete, Journal of The Korea Institute for Structural Maintenance and Inspection, 20(1), 41-47. https://doi.org/10.11112/jksmi.2016.20.1.041
  15. Seo, S., Choi, K., Kwon, Y., & Lee, K. (2016b) Flexural Strength of RC Beam Strengthened by Partially De-bonded Near-Surface-Mounted FRP Strip, International Journal of Concrete Structures and Materials, Korea Concrete Institute, 10(2), 149-161. https://doi.org/10.1007/s40069-016-0133-z
  16. Seo, S., Lee, M. S. Lee, & Feo, L. (2016c). Flexural Analysis of RC Beam Strengthened by Partially De-bonded NSM FRP Strip, Composite Part B, 101(15), 21-30. https://doi.org/10.1016/j.compositesb.2016.06.056
  17. Yoen, J., & Seo, S. (2014). Evaluation on the thermal resistance capacity of fire proof materials for improving fire resistance of near-surface-mounted FRP in concrete, Journal of the Korea Institute for Structural Maintenance and Inspection, 18(5), 51-58. https://doi.org/10.11112/jksmi.2014.18.5.051