DOI QR코드

DOI QR Code

Performance Evaluation of Combined Sewer Overflow Treatment using Filtration Pilot Device

파일럿 여과장치를 이용한 합류식하수관 월류수 처리성능 평가

  • Lee, Jun Ho (Department of Environmental Engineering, Korea National University of Transportation) ;
  • Shin, Young Gyun (Hoam Engineering, Co., Ltd.)
  • 이준호 (한국교통대학교 건설.환경.도시교통공학부) ;
  • 신용균 (호암엔지니어링(주))
  • Received : 2019.07.02
  • Accepted : 2019.09.24
  • Published : 2019.09.30

Abstract

In this study, a $480m^3/day$ pilot device was constructed through laboratory experiments based on the Ministry of Environment manual. The purpose of this study was to analyze the characteristics of CSO treatment and backwashing characteristics by applying the pilot device to the field. The purpose of this study was to acquire the basic data necessary for the design and operation management of the real scale filtration type non-point pollution control system. The filtration was conducted while maintaining the linear velocity of 20m/hour. The CSO treatment efficiencies of the pilot devices were 0.4-76.1%(mean 49.0 %), SS 51.4-91.6%(mean 77.8%), COD 22.2-59.4% (mean 38.3%) and TP 14.5-52.6%(mean 38.1%),respectively. The correlation coefficient between SS and the turbidity of influent water was 0.90, higher than that of CSO. To operate the treatment system effectively, the turbidity can be easily measured in real time as the monitoring item is the most appropriate because SS is the main target substance of the non-point source. As a result of analyzing the adsorbent treatment characteristics of PP filter material applied to this pilot device, the average particle diameter range of influent was $4.6-40.1{\mu}m$(mean $21.2{\mu}m$) and the treated water was $0.9-24.5{\mu}m$(mean $6.4{\mu}m$), respectively. Particles of approximately 10m or less are leached out, and so it is necessary to compensate for the raw water containing micro particulate matter.

Keywords

References

  1. Amirtharajah, A., McNelly, N., Page, G., and McLeod, J. (1990). Optimum backwash of dual media filters and granular activated carbon filter adsorbers with air scour, AWWA Research Foundation, 5-83.
  2. Choi, S. I. and Lee, H. S. (1996). Comparison of cleaning effect according to the different backwashing methods, Journal of Korean Society of Environmental Engineers, 18(12), 1521-1534. [Korean Literature]
  3. Flint, K. R. and Davis, A. P. (2007). Pollutant mass flushing characterization of highway stormwater runoff from an ultra-urban area, Journal of Korean Society of Environmental Engineers, 133(6), 616-626. https://doi.org/10.1061/(ASCE)0733-9372(2007)133:6(616)
  4. Hwang, Y. H., Seo, Y. G., Kim, H. W., Roh, K. W., Shin, H. S., and Kim, D. G. (2017). Optimization of operation and backwashing condition for an upflow stormwater filtration system utilizing ceramic media, Journal of Korean Society of Environmental Engineers, 39(8), 478-488. [Korean Literature] https://doi.org/10.4491/KSEE.2017.39.8.478
  5. Kim, S. H., Gwon, E. M., Park, S. S., Joh, S. J., Lim, C. H., and Kang, S. H. (2010). Identification of operating parameters in auto-discharging filter system for treatment of urban storm water, Journal of Korea Society Waste Management, 24(4), 377-386. [Korean Literature]
  6. Lee, J. H. and Bang, K. W. (2012). Performance evaluation of backwash hydrodynamic separator filter for treatment of micro particles, Journal of Korean Society of Environmental Engineers, 34(10), 694-701. [Korean Literature] https://doi.org/10.4491/KSEE.2012.34.10.694
  7. Lee, J. H., Bang, K. W., Choi, J. S., Ketchum, Jr. L. H., and Cho, Y. J. (2003). The vortex separator for suspended solids treatment, Water Science and Technology, 47(9). 335-341. https://doi.org/10.2166/wst.2003.0707
  8. Lee, J. H., Bang, K. W., and Hong, S. C. (2000). Combinded sewer overflow control using the swirl concentrator, Journal of Korean Society of Environmental Engineers, 23(1), 21-30. [Korean Literature]
  9. Lee, J. H., Bang, K. W., Ketchum, L. H., Choe, J. S., and Yu, M. J. (2002). First flush analysis of urban storm runoff, Science of The Total Environment, 293, 163-175. https://doi.org/10.1016/S0048-9697(02)00006-2
  10. Lim, C. S., Kim, D. G., and Ko, S. O. (2012). Evaluation of downflow granular media filtration for stormwater treatment, Journal of Korean Society of Environmental Engineers, 34(10), 684-693. [Korean Literature] https://doi.org/10.4491/KSEE.2012.34.10.684
  11. Leem, J. S., Park, N. S., Kim, S. H., and Park, H. K. (1999). The effect of bubble size on backwashing efficiency of biomass filter with air scour, Journal of Korean Society of Environmental Engineers, 21(12), 2321-2328. [Korean Literature]
  12. Ministry of Environment (ME). (2016). Installation and management of nonpoint pollution control facilities operation manuals, Ministry of Environment, 8. [Korean Literature]
  13. Pitcher, S. K., Slade, R. C. T., and Ward, N. I. (2004). Heavy metal removal from motorway stormwater using zeolites, Science of The Total Environment, 1334-335, 161-166. https://doi.org/10.1016/j.scitotenv.2004.04.035
  14. Rice, E. W., Baird, R. B., and Eaton, A. D. (2017). Standard Methods for the Examination of Water and Wastewater, 23rd Edition, AWWA.
  15. Sansalone, J. J. and Kim, J. Y. (2008). Suspended particle destabilization in retained urban stormwater as a function of coagulant dosage and redox conditions, Water Research, 42(4-5), 909-922. https://doi.org/10.1016/j.watres.2007.08.037
  16. Shimazu, R., Matsushima, O., and Meguro, T. (2008). Study on the simplified fiber filtration for CSO control, 11th International Conference on Urban Drainage, United Kingdom, 1-10.
  17. Shimadzu Corporation. (2019). Particle Size Analyzers, C060-E005A, https://www.ssi.shimadzu.com.
  18. Tchobanoglous, G., Stensel, H. D., Tsuchihashi, R., and Burton, F. (2014). Wastewater engineering, treatment and resource recovery, 5th Edition, Metcalf & Eddy Aecom, 80-82.