DOI QR코드

DOI QR Code

The critical angle of seismic incidence of transmission tower-line system based on wavelet energy method

  • Tian, Li (School of Civil Engineering, Shandong University) ;
  • Dong, Xu (School of Civil Engineering, Shandong University) ;
  • Pan, Haiyang (School of Civil Engineering, Shandong University) ;
  • He, Xiaoyu (Zhejiang Provincial Institute of Communication Planning, Design and Research)
  • Received : 2019.07.21
  • Accepted : 2019.09.04
  • Published : 2019.10.25

Abstract

On the basis that ground motions may arrive at a structure from any horizontal direction and that different directions of seismic incidence would result in different structural dynamic responses, this paper focuses on orienting the crucial seismic incidence of transmission tower-line systems based on the wavelet energy method. A typical transmission tower-line system is chosen as the case study, and two finite element (FE) models are established in ABAQUS, with and without consideration of the interaction between the transmission towers and the transmission lines. The mode combination frequency is defined by considering the influence of the higher-order modes of the structure. Subsequently, wavelet transformation is performed to obtain the total effective energy input and the effective energy input rate corresponding to the mode combination frequency to further judge the critical angle of seismic incidence by comparing these two performance indexes under different seismic incidence angles. To validate this approach, finite element history analysis (FEHA) is imposed on both FE models to generate comparative data, and good agreement is found. The results demonstrate that the wavelet energy method can forecast the critical angle of seismic incidence of a transmission tower-line system with adequate accuracy, avoiding time-consuming and cumbersome computer analysis. The proposed approach can be used in future seismic design of transmission tower-line systems.

Keywords

Acknowledgement

Supported by : National Natural Science Foundation of China, Shandong University

References

  1. Akehashi, H. and Takewaki, I. (2019), "Optimal viscous damper placement for elastic-plastic MDOF structures under critical double impulse", Front. Built. Environ., 5. https://doi.org/10.3389/fbuil.2019.00020.
  2. Albermani, F., Kitipornchai, S. and Chan, R.W. (2009), "Failure analysis of transmission towers", Eng. Fail. Anal., 16(6), 1922-1928. https://doi.org/10.1016/j.engfailanal.2008.10.001.
  3. Albermani, F.G.A. and Kitipornchai, S. (2003), "Numerical simulation of structural behaviour of transmission towers", Thin Wall. Struct., 41(2-3), 167-177. https://doi.org/10.1016/S0263-8231(02)00085-X.
  4. Baranov, S.V. (2007), "Application of the wavelet transform to automatic seismic signal detection", Izv-Phys. Solid Eart+, 43(2), 177-188. https://doi.org/10.1134/S1069351307020085.
  5. Bombale, B.S., Singha, M.K. and Kapuria, S. (2008), "Detection of delamination damage in composite beams and plates using wavelet analysis", Struct. Eng. Mech., 30(6), 699-712. https://doi.org/10.12989/sem.2008.30.6.699.
  6. Bravo-Imaz, I., Ardakani, H.D., Liu, Z., Garcia-Arribas, A., Arnaiz, A. and Lee, J. (2017), "Motor current signature analysis for gearbox condition monitoring under transient speeds using wavelet analysis and dual-level time synchronous averaging", Mech. Syst. Signal Pr., 94, 73-84. https://doi.org/10.1016/j.ymssp.2017.02.011.
  7. Cantagallo, C., Camata, G. and Spacone, E. (2012), "The effect of the earthquake incidence angle on seismic demand of reinforced concrete structures", Proceedings of the 15th World Conference on Earthquake Engineering, Lisbon, Portugal, September.
  8. Eslamlou, S.D. and Asgarian, B. (2017), "Determining critical areas of transmission towers due to sudden removal of members", Case Stud. Eng. Fail. Anal., 9, 138-147. https://doi.org/10.1016/j.csefa.2015.09.005.
  9. Fajfar, P. and Vidic, T. (1994), "Consistent inelastic design spectra: hysteretic and input energy", Earthq. Eng. Struct. D., 23(5), 523-537. https://doi.org/10.1002/eqe.4290230505.
  10. Fujita, K. and Takewaki, I. (2010), "Critical correlation of bidirectional horizontal ground motions", Eng. Struct., 32(1), 261-272. https://doi.org/10.1016/j.engstruct.2009.09.013.
  11. GB 18306-2015 (2015), Seismic Ground Motion Parameters Zonation Map of China, Standardization Administration of China Press, Beijing, China.
  12. GB 2695-82 (1982), Rules of Nomenclature for Transmission Poles and Towers, Electric Power Press, Beijing, China.
  13. GB 50260-2013 (2013), Code for Seismic Design of Electrical Installations, China Architecture & Building Press, Beijing, China.
  14. GB 50545-2010 (2010), Code for Design of 110kV-750kV Overhead Transmission Line, China Architecture & Building Press, Beijing, China.
  15. Ghobarah, A., Aziz, T.S. and El-Attar, M. (1996), "Response of transmission lines to multiple support excitation", Eng. Struct., 18(12), 936-946. https://doi.org/10.1016/S0141-0296(96)00020-X.
  16. Hall, J.F., Holmes, W.T. and Somers, P. (1996), "Northridge earthquake, January 17, 1994", Earthquake Engineering Research Institute, California, USA.
  17. Huang, J.Q., Du, X.L., Jin, L. and Zhao, M. (2016), "Impact of incident angles of P waves on the dynamic responses of long lined tunnels", Earthq. Eng. Struct. D., 45(15), 2435-2454. https://doi.org/10.1002/eqe.2772.
  18. Kim, H. and Melhem, H. (2004), "Damage detection of structures by wavelet analysis", Eng. Struct., 26(3), 347-362. https://doi.org/10.1016/j.engstruct.2003.10.008.
  19. Kuwamura, H., Iyama, J. and Takeda, T. (1997b), "Energy input rate of earthquake ground motion--matching of displacement theory and energy theory", J. Struct. Constr. Eng., 498, 37-42. https://doi.org/10.3130/aijs.62.37_6
  20. Kuwamura, H., Takeda, T. and Sato, Y. (1997a), "Energy input rate in earthquake destructiveness-comparison between epicentral and oceanic earthquakes", J. Struct. Constr. Eng., 491, 29-36. https://doi.org/10.3130/aijs.62.29_1
  21. Lei, Y.H. and Chien, Y.L. (2009), "Seismic analysis of transmission towers under various line configurations", Struct. Eng. Mech., 31(3), 241-264. https://doi.org/10.12989/sem.2009.31.3.241.
  22. Li, H.N., He, X.Y. and Yi, T.H. (2009), "Multi-component seismic response analysis of offshore platform by wavelet energy principle", Coast. Eng., 56(8), 810-830. https://doi.org/10.1016/j.coastaleng.2009.02.008.
  23. Li, H.N., Shi, W.L., Wang, G.X. and Jia, L.G. (2005), "Simplified models and experimental verification for coupled transmission tower.line system to seismic excitations", J. Sound Vib., 286(3), 569-585. https://doi.org/10.1016/j.jsv.2004.10.009.
  24. Lopez, O.A. and Torres, R. (1997a), "The critical angle of seismic incidence and the maximum structural response", Earthq. Eng. Struct. D., 26(9), 881-894. https://doi.org/10.1002/(SICI)1096-9845(199709)26:9<881::AID-EQE674>3.0.CO;2-R.
  25. Lopez, O.A., Chopra, A.K. and Hernandez, J.J. (2000a), "Critical response of structures to multicomponent earthquake excitation", Earthq. Eng. Struct. D., 29(12), 1759-1778. https://doi.org/10.1002/1096-9845(200012)29:12<1759::AIDEQE984> 3.0.CO;2-K.
  26. Magliulo, G., Maddaloni, G. and Petrone, C. (2014), "Influence of earthquake direction on the seismic response of irregular plan RC frame buildings", Earthq. Eng. Eng. Vib., 13(2), 243-256. https://doi.org/10.1007/s11803-014-0227-z.
  27. Menun, C. and Der Kiureghian, A. (1998), "A replacement for the 30%, 40%, and SRSS rules for multicomponent seismic analysis", Earthq. Spectra, 14(1), 153-163. https://doi.org/10.1193/1.1585993.
  28. Montanari, L., Basu, B., Spagnoli, A. and Broderick, B.M. (2015), "A padding method to reduce edge effects for enhanced damage identification using wavelet analysis", Mech. Syst. Signal Pr., 52, 264-277. https://doi.org/10.1016/j.ymssp.2014.06.014.
  29. Rigato, A.B. and Medina, R.A. (2007), "Influence of angle of incidence on seismic demands for inelastic single-storey structures subjected to bi-directional ground motions", Eng. Struct., 29(10), 2593-2601. https://doi.org/10.1016/j.engstruct.2007.01.008.
  30. Rosenblueth, E. (1951), "A basis for aseismic design", Ph.D. Dissertation, Univ. of Illinois, Urbana, IL.
  31. Roy, A., Santra, A. and Roy, R. (2018), "Estimating seismic response under bi-directional shaking per uni-directional analysis: Identification of preferred angle of incidence", Soil Dyn. Earthq. Eng., 106, 163-181. https://doi.org/10.1016/j.soildyn.2017.12.022.
  32. Shinozuka, M. (1995), "The Hanshin-Awaji earthquake of January 17, 1995 Performance of life lines", Report NCEER-95-0015, NCEER.
  33. Smeby, W. and Der Kiureghian, A. (1985), "Modal combination rules for multicomponent earthquake excitation", Earthq. Eng. Struct. D., 13(1), 1-12. https://doi.org/10.1002/eqe.4290130103.
  34. Taha, M.R., Noureldin, A., Lucero, J.L. and Baca, T.J. (2006), "Wavelet transform for structural health monitoring: a compendium of uses and features", Struct. Health Monit., 5(3), 267-295. https://doi.org/10.1177/1475921706067741.
  35. Takewaki, I. (2013), Critical Excitation Methods In Earthquake Engineering, Butterworth-Heinemann, London, England
  36. Taniguchi, R., Kojima, K. and Takewaki, I. (2016), "Critical response of 2DOF elastic-plastic building structures under double impulse as substitute of near-fault ground motion", Front. Built. Environ., 2, 2. https://doi.org/10.3389/fbuil.2016.00002.
  37. Tian, L., Fu, Z., Pan, H., Ma, R. and Liu, Y. (2019c), "Experimental and numerical study on the collapse failure of long-span transmission tower-line systems subjected to extremely severe earthquakes", Earthq. Struct., 16(5), 513-522. https://doi.org/10.12989/eas.2019.16.5.513.
  38. Tian, L., Pan, H. and Ma, R. (2019a), "Probabilistic seismic demand model and fragility analysis of transmission tower subjected to near-field ground motions", J. Constr. Steel Res., 156, 266-275. https://doi.org/10.1016/j.jcsr.2019.02.011.
  39. Tian, L., Pan, H., Ma, R. and Qiu, C. (2017), "Collapse simulations of a long span transmission tower-line system subjected to near-fault ground motions", Earthq. Struct., 13(2), 211-220. : https://doi.org/10.12989/eas.2017.13.2.211.
  40. Tian, L., Rong, K., Bi, K. and Zhang, P. (2019b), "A bidirectional pounding tuned mass damper and its application to transmission tower-line systems under seismic excitations", Int. J. Struct. Stab. Dyn., 19(6), 1950056. https://doi.org/10.1142/S0219455419500561.
  41. Tian, L., Yi, S. and Qu, B. (2018), "Orienting ground motion inputs to achieve maximum seismic displacement demands on electricity transmission towers in near-fault regions", J. Struct. Eng., 144(4), 04018017. https://doi.org/10.1061/(ASCE)ST.1943-541X.0002000.
  42. Torbol, M. and Shinozuka, M. (2012), "Effect of the angle of seismic incidence on the fragility curves of bridges", Earthq. Eng. Struct. D., 41(14), 2111-2124. https://doi.org/10.1002/eqe.2197.
  43. Uang, C.M. and Bertero, V.V. (1990), "Evaluation of seismic energy in structures", Earthq. Eng. Struct. D., 19(1), 77-90. https://doi.org/10.1002/eqe.4290190108.
  44. Wilson, E.L. and Button, M.R. (1982), "Three-dimensional dynamic analysis for multi-component earthquake spectra", Earthq. Eng. Struct. D., 10(3), 471-476. https://doi.org/10.1002/eqe.4290100309.
  45. Wimarshana, B., Wu, N. and Wu, C. (2017), "Crack identification with parametric optimization of entropy & wavelet transformation", Struct. Monit. Maint., 4(1), 33-52. https://doi.org/10.12989/smm.2017.4.1.033.
  46. Wu, G., Zhai, C., Li, S. and Xie, L. (2014), "Effects of near-fault ground motions and equivalent pulses on large crossing transmission tower-line system", Eng. Struct., 77, 161-169. https://doi.org/10.1016/j.engstruct.2014.08.013.
  47. Xie, L.L. and Zhai, C.H. (2003), "Study on the severest real ground motion for seismic design and analysis", Acta Seismologica Sinica, 25, 250-261. https://doi.org/10.1007/s11589-003-0030-9.
  48. Yamamoto, K., Fujita, K. and Takewaki, I. (2011), "Instantaneous earthquake input energy and sensitivity in base-isolated building", Struct. Des. Tall Spec., 20(6), 631-648. https://doi.org/10.1002/tal.539.
  49. Yuntian, F., Mingrui, L. and Chunzhe, L. (1991), "Elastic earthquake response analysis for complex structures", Earthq. Eng. Eng. Vib., 11(4), 77-86.
  50. Zhang, P., Song, G., Li, H.N. and Lin, Y.X. (2012), "Seismic control of power transmission tower using pounding TMD", J. Eng. Mech., 139(10), 1395-1406. https://doi.org/10.1061/(ASCE)EM.1943-7889.0000576.
  51. Zhao, B. and Taucer, F. (2010), "Performance of infrastructure during the May 12, 2008 Wenchuan earthquake in China", J. Earthqu. Eng., 14(4), 578-600. https://doi.org/10.1080/13632460903274053.
  52. Zheng, H.D., Fan, J. and Long, X.H. (2017), "Analysis of the seismic collapse of a high-rise power transmission tower structure", J. Constr. Steel Res., 134, 180-193. https://doi.org/10.1016/j.jcsr.2017.03.005.