DOI QR코드

DOI QR Code

Full mouth rehabilitation in a patient with reduced vertical dimension due to numerous tooth loss and excessie worn dentition: A case report

다수의 치아 상실과 치아 마모로 인해 수직고경이 감소된 환자의 완전 구강 회복 증례

  • Lee, Eun-Hyuk (Department of Prosthodontics, School of Dentistry, Seoul National University) ;
  • Lim, Young-Jun (Department of Prosthodontics, School of Dentistry, Seoul National University) ;
  • Kwon, Ho-Beom (Department of Prosthodontics, School of Dentistry, Seoul National University) ;
  • Kim, Myung-Joo (Department of Prosthodontics, School of Dentistry, Seoul National University)
  • 이은혁 (서울대학교 치의학대학원 치과보철학교실) ;
  • 임영준 (서울대학교 치의학대학원 치과보철학교실) ;
  • 권호범 (서울대학교 치의학대학원 치과보철학교실) ;
  • 김명주 (서울대학교 치의학대학원 치과보철학교실)
  • Received : 2019.07.05
  • Accepted : 2019.08.19
  • Published : 2019.10.31

Abstract

As digital dentistry technology is being developed, it is being used in various ways. This case covers how digital dentistry technology is being applied on the treatment of patients with loss of vertical dimension due to worn dentition and multiple loss of teeth. The loss of vertical dimension was carefully assessed and recovered, and implants were placed with surgical guides, designed considering the final restoration. The movement of the mandibular was measured with the electronic instrument for recording mandibular movement. Wax-up process was done with Naturgemäße Aufwachs-Technik (N.A.T.) and Natural functional reconstruction (N.F.R.). It was scanned, and the provisional restoration was fabricated using Computer-Aided-Design/Computer-Aided-Manufacturing (CAD/CAM) technology, and the adjustment process was done at the clinic to meet with the satisfaction both functionally and esthetically, and then, using double scanning and CAD/CAM technology, it was carried out as a final restoration. As a result, the patient obtained satisfying results, utilizing the benefits of digital dentistry technology and traditional methods.

최근 디지털 치의학 기술이 치과 치료에 다양하게 활용이 되고 있다. 본 증례는 다수의 치아 상실과 치아 마모로 수직고경이 감소한 환자의 치료에서 이러한 디지털 치의학 기술이 어떻게 적용되는지 다루고 있다. 감소한 수직고경을 주의 깊게 평가하여 회복하였고, 최종 수복물을 고려하여 설계한 수술용 가이드를 이용하여 임플란트 식립을 시행하였다. 디지털 악간관계 측정기를 이용하여 하악의 전측방 운동을 측정하여 교합기에 반영하였고, Naturgemäße Aufwachs-Technik (N.A.T.), Natural functional reconstruction (N.F.R.)을 이용한 왁스업 과정을 진행하였다. 이를 스캔하여 CAD/CAM 기술로 임시 수복물을 제작하였고, 기능적, 심미적으로 만족스러운 상태까지 진료실에서 조정과정을 거친 뒤 Computer-Aided-Design/Computer-Aided-Manufacturing (CAD/CAM) 기술을 활용하여 최종 수복물로 그대로 이행될 수 있도록 하였다. 이와 같이 디지털 치의학 기술과 전통적인 방식의 장점을 활용하여 환자와 술자 모두 만족할만한 결과를 얻었기에 이를 보고하고자 한다.

Keywords

References

  1. Pinho T, Neves M, Alves C. Multidisciplinary management including periodontics, orthodontics, implants, and prosthetics for an adult. Am J Orthod Dentofacial Orthop 2012;142:235-45. https://doi.org/10.1016/j.ajodo.2010.10.026
  2. Padwa BL, Kaiser MO, Kaban LB. Occlusal cant in the frontal plane as a reflection of facial asymmetry. J Oral Maxillofac Surg 1997;55:811-6. https://doi.org/10.1016/S0278-2391(97)90338-4
  3. Ramfjord SP, Blankenship JR. Increased occlusal vertical dimension in adult monkeys. J Prosthet Dent 1981;45:74-83. https://doi.org/10.1016/0022-3913(81)90015-9
  4. Dawson PE. Functional occlusion: From TMJ to smile design. St. Louis: Mosby Elsevier 2007.
  5. Hemmings KW, Darbar UR, Vaughan S. Tooth wear treated with direct composite restorations at an increased vertical dimension: results at 30 months. J Prosthet Dent 2000;83:287-93. https://doi.org/10.1016/S0022-3913(00)70130-2
  6. Sato S, Hotta TH, Pedrazzi V. Removable occlusal overlay splint in the management of tooth wear: a clinical report. J Prosthet Dent 2000;83:392-5. https://doi.org/10.1016/S0022-3913(00)70032-1
  7. Smith BG, Knight JK. A comparison of patterns of tooth wear with aetiological factors. Br Dent J 1984;157:16-9. https://doi.org/10.1038/sj.bdj.4805401
  8. Davies SJ, Gray RJ, Qualtrough AJ. Management of tooth surface loss. Br Dent J 2002;192:11-6, 19-23. https://doi.org/10.1038/sj.bdj.4801278
  9. Mohindra NK, Bulman JS. The effect of increasing vertical dimension of occlusion on facial aesthetics. Br Dent J 2002;192:164-8. https://doi.org/10.1038/sj.bdj.4801324
  10. Muts EJ, van Pelt H, Edelhoff D, Krejci I, Cune M. Tooth wear: a systematic review of treatment options. J Prosthet Dent 2014;112:752-9. https://doi.org/10.1016/j.prosdent.2014.01.018
  11. Lee RL, Gregory GG. Gaining vertical dimension for the deep bite restorative patient. Dent Clin North Am 1971;15:743-63.
  12. Misch CE. Contemporary implant dentistry. 3rd ed. St. Louis: Mosby; 2008.
  13. Widmann G, Bale RJ. Accuracy in computer-aided implant surgery-a review. Int J Oral Maxillofac Implants 2006;21:305-13.
  14. Abboud M, Wahl G, Calvo-Guirado JL, Orentlicher G. Application and success of two stereolithographic surgical guide systems for implant placement with immediate loading. Int J Oral Maxillofac Implants 2012;27:634-43.
  15. Abduo J, Lyons K. Clinical considerations for increasing occlusal vertical dimension: a review. Aust Dent J 2012;57:2-10. https://doi.org/10.1111/j.1834-7819.2011.01640.x
  16. Azari A, Nikzad S. Computer-assisted implantology: historical background and potential outcomes-a review. Int J Med Robot 2008;4:95-104. https://doi.org/10.1002/rcs.188
  17. Raico Gallardo YN, da Silva-Olivio IRT, Mukai E, Morimoto S, Sesma N, Cordaro L. Accuracy comparison of guided surgery for dental implants according to the tissue of support: a systematic review and meta-analysis. Clin Oral Implants Res 2017;28:602-12. https://doi.org/10.1111/clr.12841
  18. Schneider D, Schober F, Grohmann P, Hammerle CH, Jung RE. In-vitro evaluation of the tolerance of surgical instruments in templates for computer-assisted guided implantology produced by 3-D printing. Clin Oral Implants Res 2015;26:320-5.
  19. Karl M, Graef F, Wichmann M, Krafft T. Passivity of fit of CAD/CAM and copy-milled frameworks, veneered frameworks, and anatomically contoured, zirconia ceramic, implantsupported fixed prostheses. J Prosthet Dent 2012;107:232-8. https://doi.org/10.1016/S0022-3913(12)60067-5
  20. Kim Y, Oh TJ, Misch CE, Wang HL. Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale. Clin Oral Implants Res 2005;16:26-35. https://doi.org/10.1111/j.1600-0501.2004.01067.x