DOI QR코드

DOI QR Code

Reliability of joint angle during sit-to-stand movements in persons with stroke using portable gait analysis system based wearable sensors

  • An, Jung-Ae (Department of Physical Therapy, Seoul Now Hospital) ;
  • Lee, Byoung-Hee (Department of Physical Therapy, College of Health Science and Social Welfare, Sahmyook University)
  • Received : 2019.08.29
  • Accepted : 2019.09.18
  • Published : 2019.09.30

Abstract

Objective: The purpose of this study was to investigate the test-retest reliability and concurrent validity of the joint angle of the lower extremities during sit-to-stand movements with wearable sensors based on a portable gait analysis system (PGAS), and the results were compared with a analysis system (MAS) to predict the clinical potential of it. Design: Cross-sectional study. Methods: Sixteen persons with stroke (9 males, 7 females) participated in this study. All subjects had the MAS and designed PGS applied simultaneously and eight sensor units of designed PGAS were placed in a position to avoid overlap with the reflexive markers from MAS. The initial position of the subjects was 90º of hip, knee, and ankle joint flexion while sitting on a chair that was armless and backless. The height of the chair was adjusted to each individual. After each trial, the test administrator checked the quality of data from both systems that measured sit-to-stand for test-retest reliability and concurrent validity. Results: As a result, wearable sensor based designed PGAS and MAS demonstrated reasonable test-retest reliability for the assessment of joint angle in the lower extremities during sit-to-stand performance. The intra-class correlation coefficients (ICCs) for wearable sensor based designed PGAS showed an acceptable test-retest reliability, with ICCs ranging from 0.759 to 0.959. In contrast, the MAS showed good to excellent test-retest reliability, with ICCS ranging from 0.811 to 0.950. In concurrent validity, a significant positive relationship was observed between PGAS and MAS for variation of joint angle during sit-to-stand movements (p<0.01). A moderate to high relationship was found in the affected hip (r=0.665), unaffected hip (r=0.767), affected knee (r=0.876), unaffected knee (r=0.886), affected ankle (r=0.943) and unaffected ankle (r=0.823) respectively. Conclusions: The results of this study indicated that wearable sensor based designed PGAS showed acceptable test-retest reliability and concurrent validity in persons with stroke for sit-to-stand movements and wearable sensors based on developed PGAS may be a useful tool for clinical assessment of functional movement.

Keywords

References

  1. Camargos AC, Rodrigues-de-Paula-Goulart F, Teixeira-Salmela LF. The effects of foot position on the performance of the sit-to-stand movement with chronic stroke subjects. Arch Phys Med Rehabil 2009;90:314-9. https://doi.org/10.1016/j.apmr.2008.06.023
  2. Lomaglio MJ, Eng JJ. Muscle strength and weight-bearing symmetry relate to sit-to-stand performance in individuals with stroke. Gait Posture 2005;22:126-31. https://doi.org/10.1016/j.gaitpost.2004.08.002
  3. Chou SW, Wong AM, Leong CP, Hong WS, Tang FT, Lin TH. Postural control during sit-to stand and gait in stroke patients. Am J Phys Med Rehabil 2003;82:42-7. https://doi.org/10.1097/00002060-200301000-00007
  4. Liu M, Chen J, Fan W, Mu J, Zhang J, Wang L, et al. Effects of modified sit-to-stand training on balance control in hemiplegic stroke patients: a randomized controlled trial. Clin Rehabil 2016;30:627-36. https://doi.org/10.1177/0269215515600505
  5. Jung KS, In TS, Cho HY. Effects of sit-to-stand training combined with transcutaneous electrical stimulation on spasticity, muscle strength and balance ability in patients with stroke: a randomized controlled study. Gait Posture 2017;54:183-7. https://doi.org/10.1016/j.gaitpost.2017.03.007
  6. Pollock A, Gray C, Culham E, Durward BR, Langhorne P. Interventions for improving sit-to-stand ability following stroke. Cochrane Database Syst Rev 2014;(5):CD007232.
  7. Lee MY, Lee HY. Analysis for sit-to-stand performance according to the angle of knee flexion in individuals with hemiparesis. J Phys Ther Sci 2013;25:1583-5. https://doi.org/10.1589/jpts.25.1583
  8. Tao W, Liu T, Zheng R, Feng H. Gait analysis using wearable sensors. Sensors (Basel) 2012;12:2255-83. https://doi.org/10.3390/s120202255
  9. Bruckner HP, Nowosielski R, Kluge H, Blume H. Mobile and wireless inertial sensor platform for motion capturing in stroke rehabilitation sessions. Paper presented at: 5th IEEE International Workshop on Advances in Sensors and Interfaces IWASI;2013 Jun 13-14; Bari, Italy.
  10. Jonsdottir J, Recalcati M, Rabuffetti M, Casiraghi A, Boccardi S, Ferrarin M. Functional resources to increase gait speed in people with stroke: strategies adopted compared to healthy controls. Gait Posture 2009;29:355-9. https://doi.org/10.1016/j.gaitpost.2009.01.008
  11. Bertolucci PHF, Brucki SMD, Campacci SR, Juliano Y. The mini-mental state examination in an outpatient population: influence of literacy. Arq Neuropsiquiatria 1994;52:1-7. https://doi.org/10.1590/S0004-282X1994000100001
  12. Kwong PW, Ng SS, Chung RC, Ng GY. Foot placement and arm position affect the five times sit-to-stand test time of individuals with chronic stroke. Biomed Res Int 2014. doi: 10.1155/2014/636530.
  13. Mizuike C, Ohgi S, Morita S. Analysis of stroke patient walking dynamics using a tri-axial accelerometer. Gait Posture 2009;30:60-4. https://doi.org/10.1016/j.gaitpost.2009.02.017
  14. Bruijn SM, Meijer OG, van Dieen JH, Kingma I, Lamoth CJ. Coordination of leg swing, thorax rotations, and pelvis rotations during gait: the organisation of total body angular momentum. Gait Posture 2008;27:455-62. https://doi.org/10.1016/j.gaitpost.2007.05.017
  15. Cappozzo A, Della Croce U, Leardini A, Chiari L. Human movement analysis using stereophotogrammetry. Part 1: theoretical background. Gait Posture 2005;21:186-96. https://doi.org/10.1016/S0966-6362(04)00025-6
  16. Cooper G, Sheret I, McMillan L, Siliverdis K, Sha N, Hodgins D, et al. Inertial sensor-based knee flexion/extension angle estimation. J Biomech 2009;42:2678-85. https://doi.org/10.1016/j.jbiomech.2009.08.004
  17. Alandry B, Dumas N, Latorre L, Mailly F, Nouet P. A CMOS multi-sensor system for 3D orientation determination. Paper presented at: 2008 IEEE Computer Society Annual Symposium on VLSI; 2008 Apr 7-9; Montpellier, France.
  18. Kok M, Hol JD, Schon TB, Gustafsson F, Luinge H. Calibration of a magnetometer in combination with inertial sensors. Paper presented at: 2012 15th International Conference on Information Fusion; 2012 Jul 9-12; Singapore.
  19. Rankin G, Stokes M. Reliability of assessment tools in rehabilitation: an illustration of appropriate statistical analyses. Clin Rehabil 1998;12:187-99. https://doi.org/10.1191/026921598672178340
  20. Muro-de-la-Herran A, Garcia-Zapirain B, Mendez-Zorrilla A. Gait analysis methods: an overview of wearable and non-wearable systems, highlighting clinical applications. Sensors (Basel) 2014;14:3362-94. https://doi.org/10.3390/s140203362
  21. Galli M, Cimolin V, Crivellini M, Campanini I. Quantitative analysis of sit to stand movement: experimental set-up definition and application to healthy and hemiplegic adults. Gait Posture 2008;28:80-5. https://doi.org/10.1016/j.gaitpost.2007.10.003
  22. Schenkman M, Berger RA, Riley PO, Mann RW, Hodge WA. Whole-body movements during rising to standing from sitting. Phys Ther 1990;70:638-48; discussion 648-51. https://doi.org/10.1093/ptj/70.10.638
  23. Duclos C, Nadeau S, Lecours J. Lateral trunk displacement and stability during sit-to-stand transfer in relation to foot placement in patients with hemiparesis. Neurorehabil Neural Repair 2008;22:715-22. https://doi.org/10.1177/1545968308316000
  24. Joshua AM, Karnad SD, Nayak A, Suresh BV, Mithra P, Unnikrishnan B. Effect of foot placements during sit to stand transition on timed up and go test in stroke subjects: a cross sectional study. NeuroRehabilitation 2017;40:355-62. https://doi.org/10.3233/NRE-161423
  25. Brunt D, Greenberg B, Wankadia S, Trimble MA, Shechtman O. The effect of foot placement on sit to stand in healthy young subjects and patients with hemiplegia. Arch Phys Med Rehabil 2002;83:924-9. https://doi.org/10.1053/apmr.2002.3324
  26. Nyberg L, Gustafson Y. Fall prediction index for patients in stroke rehabilitation. Stroke 1997;28:716-21. https://doi.org/10.1161/01.STR.28.4.716

Cited by

  1. A Novel Simplified System to Estimate Lower-Limb Joint Moments during Sit-to-Stand vol.21, pp.2, 2021, https://doi.org/10.3390/s21020521
  2. A Comparative Study on Clinical Gait Abilities of Stroke Patients According to Indoor and Outdoor Environments vol.10, pp.3, 2019, https://doi.org/10.14474/ptrs.2021.10.3.356