DOI QR코드

DOI QR Code

Feasibility of Spin-Echo Echo-Planar Imaging MR Elastography in Livers of Children and Young Adults

  • Kim, Jin Kyem (Department of Radiology and Research Institute of Radiological Science, Yonsei University College of Medicine) ;
  • Yoon, Haesung (Department of Radiology and Research Institute of Radiological Science, Yonsei University College of Medicine) ;
  • Lee, Mi-Jung (Department of Radiology and Research Institute of Radiological Science, Yonsei University College of Medicine) ;
  • Kim, Myung-Joon (Department of Radiology and Research Institute of Radiological Science, Yonsei University College of Medicine) ;
  • Han, Kyunghwa (Department of Radiology, Research Institute of Radiological Science, Center for Clinical Imaging Data Science, Yonsei University College of Medicine) ;
  • Koh, Hong (Department of Pediatric Gastroenterology, Hepatology and Nutrition, Yonsei University College of Medicine) ;
  • Kim, Seung (Department of Pediatric Gastroenterology, Hepatology and Nutrition, Yonsei University College of Medicine) ;
  • Han, Seok Joo (Department of Pediatric Surgery, Yonsei University College of Medicine) ;
  • Shin, Hyun Joo (Department of Radiology and Research Institute of Radiological Science, Yonsei University College of Medicine)
  • Received : 2019.06.11
  • Accepted : 2019.07.09
  • Published : 2019.09.30

Abstract

Purpose: To assess the feasibility of the use of spin-echo echo-planar imaging (SE-EPI) magnetic resonance elastography (MRE) in livers of children and young adults. Materials and Methods: Patients (${\leq}20$ years old) who underwent 3T SE-EPI MRE were included retrospectively. Subjects were divided into three groups according to the purpose of the liver MRI: suspicion of fatty liver or focal fat deposition in the liver (FAT group), liver fibrosis after receiving a Kasai operation from biliary atresia (BA group), and hepatic iron deposition after receiving chemotherapy or transfusions (IRON group). Technical failure of MRE was defined when a stiffness map showed no pixel value with a confidence index higher than 95%, and the patients were divided as success and failure groups accordingly. Clinical findings including age, gender, weight, height, and body mass index and magnetic resonance imaging results including proton density fat fraction (PDFF), $T2^*$, and MRE values were assessed. Factors affecting failure of MRE were evaluated and the image quality in wave propagation image and stiffness map was evaluated using the appropriate scores. Results: Among total 240 patients (median 15 years, 211 patients in the FAT, 21 patients in the BA, and 8 patients in the IRON groups), technical failure was noted in six patients in the IRON group (6/8 patients, 75%), while there were no failures noted in the FAT and BA groups. These six patients had $T2^*$ values ranging from 0.9 to 3.8 ms. The image quality scores were not significantly different between the FAT and BA groups (P > 0.999), while the scores were significantly lower in the IRON group (P < 0.001). Conclusion: The 3T SE-EPI MRE in children and young adults had a high technical success rate. The technical failure was occurred in children with decreased $T2^*$ value (${\leq}3.8ms$) from iron deposition.

Keywords

References

  1. Bonekamp S, Kamel I, Solga S, Clark J. Can imaging modalities diagnose and stage hepatic fibrosis and cirrhosis accurately? J Hepatol 2009;50:17-35 https://doi.org/10.1016/j.jhep.2008.10.016
  2. Mavis AM, Alonso EM. Liver disease in the adolescent. Clin Liver Dis 2015;19:171-185 https://doi.org/10.1016/j.cld.2014.09.010
  3. Friedman SL. Evolving challenges in hepatic fibrosis. Nat Rev Gastroenterol Hepatol 2010;7:425-436 https://doi.org/10.1038/nrgastro.2010.97
  4. Bortolotti F, Guido M. Reversal of liver cirrhosis: a desirable clinical outcome and its pathogenic background. J Pediatr Gastroenterol Nutr 2007;44:401-406 https://doi.org/10.1097/MPG.0b013e318032069a
  5. Castera L, Pinzani M. Biopsy and non-invasive methods for the diagnosis of liver fibrosis: does it take two to tango? Gut 2010;59:861-866 https://doi.org/10.1136/gut.2010.214650
  6. Pariente D, Franchi-Abella S. Paediatric chronic liver diseases: how to investigate and follow up? Role of imaging in the diagnosis of fibrosis. Pediatr Radiol 2010;40:906-919 https://doi.org/10.1007/s00247-010-1600-3
  7. Kennedy P, Wagner M, Castera L, et al. Quantitative elastography methods in liver disease: current evidence and future directions. Radiology 2018;286:738-763 https://doi.org/10.1148/radiol.2018170601
  8. Trout AT, Sheridan RM, Serai SD, et al. Diagnostic performance of MR elastography for liver fibrosis in children and young adults with a spectrum of liver diseases. Radiology 2018;287:824-832 https://doi.org/10.1148/radiol.2018172099
  9. Singh S, Venkatesh SK, Wang Z, et al. Diagnostic performance of magnetic resonance elastography in staging liver fibrosis: a systematic review and metaanalysis of individual participant data. Clin Gastroenterol Hepatol 2015;13:440-451 e446 https://doi.org/10.1016/j.cgh.2014.09.046
  10. Serai SD, Dillman JR, Trout AT. Spin-echo echo-planar imaging MR elastography versus gradient-echo MR elastography for assessment of liver stiffness in children and young adults suspected of having liver disease. Radiology 2017;282:761-770 https://doi.org/10.1148/radiol.2016160589
  11. Kim YS, Jang YN, Song JS. Comparison of gradient-recalled echo and spin-echo echo-planar imaging MR elastography in staging liver fibrosis: a meta-analysis. Eur Radiol 2018;28:1709-1718 https://doi.org/10.1007/s00330-017-5149-5
  12. Felker ER, Choi KS, Sung K, et al. Liver MR elastography at 3 T: agreement across pulse sequences and effect of liver R2* on image quality. AJR Am J Roentgenol 2018;211:588-594 https://doi.org/10.2214/AJR.17.19288
  13. Wagner M, Corcuera-Solano I, Lo G, et al. Technical failure of MR elastography examinations of the liver: experience from a large single-center study. Radiology 2017;284:401-412 https://doi.org/10.1148/radiol.2016160863
  14. Joshi M, Dillman JR, Towbin AJ, Serai SD, Trout AT. MR elastography: high rate of technical success in pediatric and young adult patients. Pediatr Radiol 2017;47:838-843 https://doi.org/10.1007/s00247-017-3831-z
  15. Alustiza Echeverria JM, Castiella A, Emparanza JI. Quantification of iron concentration in the liver by MRI. Insights Imaging 2012;3:173-180 https://doi.org/10.1007/s13244-011-0132-1
  16. Shin HJ, Kim HG, Kim MJ, et al. Normal range of hepatic fat fraction on dual- and triple-echo fat quantification MR in children. PLoS One 2015;10:e0117480 https://doi.org/10.1371/journal.pone.0117480
  17. Wahidiyat PA, Iskandar SD, Sekarsari D. Evaluation of iron overload between age groups using magnetic resonance imaging and its correlation with iron profile in transfusiondependent thalassemia. Acta Med Indones 2018;50:230-236
  18. Serai SD, Towbin AJ, Podberesky DJ. Pediatric liver MR elastography. Dig Dis Sci 2012;57:2713-2719 https://doi.org/10.1007/s10620-012-2196-2
  19. Binkovitz LA, El-Youssef M, Glaser KJ, Yin M, Binkovitz AK, Ehman RL. Pediatric MR elastography of hepatic fibrosis: principles, technique and early clinical experience. Pediatr Radiol 2012;42:402-409 https://doi.org/10.1007/s00247-011-2298-6
  20. Petitclerc L, Sebastiani G, Gilbert G, Cloutier G, Tang A. Liver fibrosis: review of current imaging and MRI quantification techniques. J Magn Reson Imaging 2017;45:1276-1295 https://doi.org/10.1002/jmri.25550
  21. Mariappan YK, Glaser KJ, Ehman RL. Magnetic resonance elastography: a review. Clin Anat 2010;23:497-511 https://doi.org/10.1002/ca.21006
  22. Srinivasa Babu A, Wells ML, Teytelboym OM, et al. Elastography in chronic liver disease: modalities, techniques, limitations, and future directions. Radiographics 2016;36:1987-2006 https://doi.org/10.1148/rg.2016160042
  23. Wagner M, Besa C, Bou Ayache J, et al. Magnetic resonance elastography of the liver: qualitative and quantitative comparison of gradient echo and spin echo echoplanar imaging sequences. Invest Radiol 2016;51:575-581 https://doi.org/10.1097/RLI.0000000000000269
  24. Rump J, Klatt D, Braun J, Warmuth C, Sack I. Fractional encoding of harmonic motions in MR elastography. Magn Reson Med 2007;57:388-395 https://doi.org/10.1002/mrm.21152
  25. Venkatesh SK, Yin M, Ehman RL. Magnetic resonance elastography of liver: technique, analysis, and clinical applications. J Magn Reson Imaging 2013;37:544-555 https://doi.org/10.1002/jmri.23731
  26. Yin M, Glaser KJ, Talwalkar JA, Chen J, Manduca A, Ehman RL. Hepatic MR elastography: clinical performance in a series of 1377 consecutive examinations. Radiology 2016;278:114-124 https://doi.org/10.1148/radiol.2015142141
  27. Serai SD, Trout AT. Can MR elastography be used to measure liver stiffness in patients with iron overload? Abdom Radiol (NY) 2019;44:104-109 https://doi.org/10.1007/s00261-018-1723-9
  28. Kim YS, Song JS, Kannengiesser S, Seo SY. Comparison of spin-echo echoplanar imaging and gradient recalled echo-based MR elastography at 3 Tesla with and without gadoxetic acid administration. Eur Radiol 2017;27:4120-4128 https://doi.org/10.1007/s00330-017-4781-4