This paper proposes damage indices efficient on evaluating the seismic safety of cable-stayed bridges, especially dual-plane, cable-stayed bridges with H-type pylons. The research assumes that the location of accelerometers is already defined as given in the 2017 Ministry of the Interior and Safety (MOIS) guideline. In other words, the paper does not attempt to suggest optimal sensor location for the seismic safety evaluation of cable-stayed bridges. The proposed damage indices are based on those for building structures widely applied in the field already. Those include changes in natural frequencies and changes in relative lateral displacements. In addition, the study proposes other efficient damage indices as the rotation changes at the top of pylons and in the midspan of the girder system. Sensitivity analysis for various damage indices is performed through dynamic analysis using selected earthquake ground motions. The paper compares the effectiveness of the damage indices.

Keywords

References

  1. Chiu JM, Kim SG. Estimation of regional seismic hazard in the Korean peninsula using historical earthquakes data between A.D.2 and 1995. Bulletin of the seismological society of America. 2004 Feb;94(1):269-284. https://doi.org/10.1785/0120010256
  2. Korea Meteorological Administration. Earthquake Report 2017. c2018 Apr.
  3. Anastasopoulos I, Anastasopoulos P.Ch, Agalianos A, Sakellariadis L. Simple method for real-time seismic damage assessment of bridges. Soil dynamics and earthquake engineering. 2015;78:201-212. https://doi.org/10.1016/j.soildyn.2015.07.005
  4. Liel AB, Haselton CB. Lessons learned from seismic collapse assessment of buildings for evaluation of bridge structures. Lifeline earthquake engineering in a multihazard environment ASCE. 2009;1151-1162.
  5. Zhu L, Elwood KJ, Haukaas T. Classification and seismic safety evaluation of existing reinforced concrete columns. Journal of structural engineering, ASCE. 2007 Sep;133(9).
  6. Carreno ML, Cardona OD, Eeri M, Barbat AH. Computational tool for post-earthquake evaluation of damage in buildings. Earthquake spectra. 2010 Feb;26(1):63-86. https://doi.org/10.1193/1.3282885
  7. Ministry of the Interior and Safety. Installation and operation standard of seismic accelerometer sensors 2017, article 22, location and number of seismic acceleration sensors installations. c2017; p. 6.
  8. Ministry of Land Infrastructure and Transport. the Limit-State based Bridge Design Specification - Cable Bridge 2016. c2016;9-1-9-19.
  9. Yoon SW, Park Y, Ji JH, Lim JH, Jang DW. Vibration characteristics of a three-story reinforced concrete building before and after damage. Journal of Korean association for spacial structures. 2009 Sep;9(3):59-66.