DOI QR코드

DOI QR Code

Development of the Smart Device for Real Time Water Quality Monitoring

실시간 수질 모니터링을 위한 스마트 디바이스의 개발

  • 류대현 (한세대학교 IT학부) ;
  • 최태완 (경남과학기술대학교 메카트로닉스공학과)
  • Received : 2019.06.03
  • Accepted : 2019.08.15
  • Published : 2019.08.31

Abstract

Citizens' distrust of water pollution is very high in tap water that we routinely drink. In addition, water pollution accidents of tap water are difficult to predict and the risk is high, so real-time monitoring and management are needed. Therefore, it is necessary to introduce real-time water quality monitoring using the Internet of things(IoT). Residual chlorine is more persistent and economical than other disinfectants and it is easy to check residual effect, so it is mainly used as a disinfection index in waterworks. It can be monitored in real time by using IoT technology in order to secure the safety of tap water. In this study, we developed smart device for real-time water quality monitoring using amperometry sensor and analyzed its performance.

우리가 일상적으로 마시는 수돗물의 경우 수질의 오염에 대한 시민들의 불신은 매우 높은 편이다. 또한 수돗물의 수질오염사고는 예측이 어렵고 그 위험이 커서 실시간 모니터링과 관리가 필요하다. 따라서 사물인터넷을 이용한 실시간 수질 모니터링의 도입이 필요한 분야라 할 수 있다. 잔류염소는 다른 소독제보다 잔류성 및 경제성이 우수하고 잔류효과 확인이 쉬워 상수도에서 주로 소독 지표로 활용되는데 수돗물의 안전성을 확보하는 차원에서 사물인터넷기술을 이용하여 실시간으로 감시가 가능하다. 본 연구에서는 전류법 센서를 이용하여 실시간 수질 모니터링을 위한 스마트 디바이스를 개발하고 그 성능을 분석하였다.

Keywords

KCTSAD_2019_v14n4_723_f0001.png 이미지

그림 1. 전체 시스템 개념도 Fig. 1 Total system concept

KCTSAD_2019_v14n4_723_f0002.png 이미지

그림 2. ARCL200 Fig. 2 ARCL200

KCTSAD_2019_v14n4_723_f0003.png 이미지

그림 3. 블록도 및 회로도 Fig. 3 The entire block diagram and circuits

KCTSAD_2019_v14n4_723_f0004.png 이미지

그림 4. 제작 보드 Fig. 4 Implemented board

KCTSAD_2019_v14n4_723_f0005.png 이미지

그림 5. 웹 인터페이스 Fig. 5 Web Interface

KCTSAD_2019_v14n4_723_f0006.png 이미지

그림 6. 웹 인터페이스 화면 및 캘리브레이션 화면 Fig. 6 Web Interface UI & calibration UI

KCTSAD_2019_v14n4_723_f0007.png 이미지

그림 7. 시험 결과 Fig. 7 Result

References

  1. H. Han and J. Kim, "Toward An IoT-based Water and Environment Management System: Opportunities, Challenges, and Policy Options," Korea Environment Institute, Oct. 2016.
  2. P. Shin, Y. Song, and Y. Choi, "Case-study; Reduction of Red Water in distribution water supply system by On-Line water quality monitoring," Proc. of 2007 Fall Conference, Korean Society of Environmental Engineers, Nov. 2007, pp. 1049-1053.
  3. H. Kim and N. Jung, "Effectiveness of the Electrochemical Sensor for the Free Chlorine Measurement," Journal of the Korean Society of Manufacturing Technology Engineers, vol. 25, no. 5 Oct. 2012, pp. 720-725.
  4. Y. Heo, W. Park, J. Whang, and C. Park, "Fabrication and Evaluation of Ag/AgCl Reference Electrode," ELECTRONIC MATERIALS LETTERS, vol. 3, no. 1, Mar. 2007, pp. 33-38.
  5. Y. Oh and S. Lee, "IoT and the open source development platform," J. of the Korean Institute of Information Scientists and Engineers, vol. 32, no. 6, June 2014, pp. 25-30.
  6. D. Ryu, "Development of BLE Sensor Module based on Open Source for IoT Applications," J. of the Korea Institute of Electronic Communication Sciences, vol. 10, no. 3, Mar. 2015, pp. 419-424. https://doi.org/10.13067/JKIECS.2015.10.3.419
  7. D. Ryu, "Development of IoT Gateway based on Open Source H/W," J. of the Korea Institute of Electronic Communication Sciences, vol. 10, no. 9, Sept. 2015, pp. 1066-1070.
  8. D. Ryu and T. Choi, "Development of Open IoT platform based on Open Source Hardware & Cloud Service," J. of the Korea Institute of Electronic Communication Sciences, vol. 11, no. 5, Mar. 2016, pp. 485-490. https://doi.org/10.13067/JKIECS.2016.11.5.485
  9. D. Ryu and T. Choi, "Development of the Compact Smart Device for Industrial IoT," J. of the Korea Institute of Electronic Communication Sciences, vol. 13, no. 4, Aug. 2018, pp. 751-756. https://doi.org/10.13067/JKIECS.2018.13.4.751