Abstract

Purpose: The objective of this study is to evaluate the geometrical accuracy of a patient-specific bolus based on a three-dimensional (3D) printed mold and casting method. Materials and Methods: Three breast cancer patients undergoing treatment for a superficial region were scanned using computed tomography (CT) and a designed bolus structure through a treatment planning system (TPS). For the fabrication of patient-specific bolus, we cast harmless certified silicone into 3D printed molds. The produced bolus was also imaged using CT under the same conditions as the patient CT to acquire its geometrical shape. We compared the shapes of the produced bolus with the planned bolus structure from the TPS by measuring the average distance between two structures after a surface registration. Results and Conclusions: The result of the average difference in distance was within 1 mm and, as the worst case, the absolute difference did not exceed ${\pm}2mm$. The result of the geometric difference in the cross-section profile of each bolus was approximately 1 mm, which is a similar property of the average difference in distance. This discrepancy was negligible in affecting the dose reduction. The proposed fabrication of patient-specific bolus is useful for radiation therapy in the treatment of superficial regions, particularly those with an irregular shape.

Keywords

References

  1. Vyas V, Palmer L, Mudge R, Jiang R, Fleck A, Schaly B, et al. On bolus for megavoltage photon and electron radiation therapy. Med Dosim. 2013;38(3):268-73. https://doi.org/10.1016/j.meddos.2013.02.007
  2. Hsu SH, Roberson PL, Chen Y, Marsh RB, Pierce LJ, Moran JM. Assessment of skin dose for breast chest wall radiotherapy as a function of bolus material. Phys Med Biol. 2008;53(10):2593-606. https://doi.org/10.1088/0031-9155/53/10/010
  3. Butson MJ, Cheung T, Yu P, Metcalfe P. Effect on skin dose from unwanted air gaps under bolus in photon beam radiotherapy. Rad Meas. 2000;32:201-4. https://doi.org/10.1016/S1350-4487(99)00276-0
  4. Kim SW, Shin HJ, Kay CS, Son SH. A customized bolus produced using a 3-dimensional printer for radiotherapy. PLoS One. 2014;9(10):e110746. https://doi.org/10.1371/journal.pone.0110746
  5. Su S, Moran K, Robar JL. Design and production of 3D printed bolus for electron radiation therapy. J Appl Clin Med Phys. 2014;15(4):4831.
  6. Park SY, Choi CH, Park JM, Chun M, Han JH, Kim JI. A patient-specific polylactic acid bolus made by a 3D printer for breast cancer radiation therapy. PLoS One. 2016;11(12):e0168063. https://doi.org/10.1371/journal.pone.0168063
  7. Ricotti R, Ciardo D, Pansini F, Bazani A, Comi S, Spoto R, et al. Dosimetric characterization of 3D printed bolus at different infill percentage for external photon beam radiotherapy. Phys Med. 2017;39:25-32. https://doi.org/10.1016/j.ejmp.2017.06.004
  8. Zhao Y, Moran K, Yewondwossen M, Allan J, Clarke S, Rajaraman M, et al. Clinical applications of 3-dimensional printing in radiation therapy. Med Dosim. 2017;42(2):150-5. https://doi.org/10.1016/j.meddos.2017.03.001
  9. Robar JL, Moran K, Allan J, Clancey J, Joseph T, Chytyk-Praznik K, et al. Intrapatient study comparing 3D printed bolus versus standard vinyl gel sheet bolus for postmastectomy chest wall radiation therapy. Pract Radiat Oncol. 2018;8(4):221-9. https://doi.org/10.1016/j.prro.2017.12.008
  10. Ha JS, Jung JH, Kim MJ, Jeon MJ, Jang WS, Cho YJ, et al. Customized 3D printed bolus for breast reconstruction for modified radical mastectomy (MRM). Progress in Medical Physics. 2016;27(4).
  11. Besl PJ, Mckay ND. A method for registration of 3-D shapes. Ieee T Pattern Anal. 1992;14(2):239-56. https://doi.org/10.1109/34.121791

Cited by

  1. Low Magnetic Field MRI Visibility of Rubber-Based Markers vol.30, pp.4, 2019, https://doi.org/10.14316/pmp.2019.30.4.89
  2. Bio-compatible patient-specific elastic bolus for clinical implementation vol.64, pp.10, 2019, https://doi.org/10.1088/1361-6560/ab1c93
  3. The possibility of developing customized 3D-printed silicone hydrogel bolus for post-mastectomy radiotherapy vol.14, pp.1, 2021, https://doi.org/10.1080/16878507.2021.1962629
  4. Dose calculation of 3D printing lead shield covered by biocompatible silicone for electron beam therapy vol.44, pp.4, 2021, https://doi.org/10.1007/s13246-021-01041-y