Graft Perforation by a Spinal Bony Spur: An Unusual Cause of Late Bleeding after Thoracoabdominal Aorta Replacement

  • Yoon, Seung Hwan (Department of Thoracic and Cardiovascular Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine) ;
  • Park, Kay-Hyun (Department of Thoracic and Cardiovascular Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine)
  • Received : 2018.08.23
  • Accepted : 2018.09.13
  • Published : 2019.06.05

Abstract

We report an unusual case of delayed bleeding after open surgical repair of a thoracoabdominal aortic aneurysm. A 79-year-old man developed a massive retroperitoneal hematoma 49 days after Crawford type III thoracoabdominal aorta replacement. During emergency surgery, a tear was found in the prosthetic vascular graft caused by a sharp bony spur arising from the second lumbar vertebral body. This rare, but potentially lethal, complication indicates that attention should be paid to sharp bony structures during open repair of the descending aorta.

Keywords

References

  1. Ascher E, Veith FJ, Gloviczki P, et al. Haimovici's vascular surgery. 6th ed. Chichester: Wiley-Blackwell; 2012.
  2. Khan A, Farnan T, Hall SJ, McClure MJ. Cervical osteophyte causing perforation of the nasopharynx. Ulster Med J 2004;73:57-8.
  3. Sauvageau A, Kremer C, Racette S. Traumatic heart perforation by a D5 osteophyte: a case report. Med Sci Law 2007;47:350-2. https://doi.org/10.1258/rsmmsl.47.4.350
  4. Muretti M, Manca M, Portoghese M. Uncommon back pain after cardiac surgery: left atrium deformed by huge osteophyte. Asian Cardiovasc Thorac Ann 2016;24:735. https://doi.org/10.1177/0218492315585650
  5. Dregelid E, Jenssen G, Jonung T, Braaten A. Pseudoaneurysm of the abdominal aorta due to a needle-like osteophyte on the first lumbar vertebra. J Vasc Surg 2007;45:1059-61. https://doi.org/10.1016/j.jvs.2006.12.070
  6. Vernon SA, Murphy WR, Murphy TW, Haan JM. Abdominal aortic rupture from an impaling osteophyte following blunt trauma. J Vasc Surg 2014;59:1112-5. https://doi.org/10.1016/j.jvs.2013.04.062
  7. Yamamoto H, Yamamoto F, Ishibashi K, Noishiki Y. Vascular prosthesis rupture caused by contact with rib stump after thoracic aorta replacement. J Vasc Surg 2009;50:195-7. https://doi.org/10.1016/j.jvs.2009.01.064
  8. Ozaki N, Wakita N, Tanaka Y, Yuji D. The life-threatening complication of a vascular graft rupture early after a thoracic aortic replacement. Eur J Cardiothorac Surg 2012;42:737-8. https://doi.org/10.1093/ejcts/ezs258