DOI QR코드

DOI QR Code

Study on axial compressive behavior of quadruple C-channel built-up cold-formed steel columns

  • 투고 : 2017.12.04
  • 심사 : 2019.03.05
  • 발행 : 2019.05.25

초록

In this study, the axial compressive behavior of novel quadruple C-channel built-up cold-formed steel columns with different slenderness ratio was investigated, using the experimental and numerical analysis. The axial compressive capacity and failure modes of the columns were obtained and analyzed. The finite element models considering the geometry, material and contact nonlinearity were developed to simulate and analyze the structural behavior of the columns further. There was a great correlation between the numerical analyses and test results, which indicated that the finite element model was reasonable and accurate. Then influence of, slenderness ratio, flange width-to-thickness ratio and screw spacing on the mechanical behavior of the columns were studied, respectively. The tests and numerical results show that due to small slenderness ratio, the failure modes of the specimens are generally local buckling and distortional buckling. The axial compressive strength and stiffness of the quadruple C-channel built-up cold-formed steel columns decrease with the increase of maximum slenderness ratio. When the screw spacing is ranging from 150mm to 450mm, the axial compressive strength and stiffness of the quadruple C-channel built-up cold-formed steel columns change little. The axial compressive capacity of quadruple C-channel built-up cold-formed steel columns increases with the decrease of flange width-thickness ratio. A modified effective length factor is proposed to quantify the axial compressive capacity of the quadruple C-channel built-up cold-formed steel columns with U-shaped track in the ends.

키워드

과제정보

연구 과제 주관 기관 : National Natural Science Foundation of China, Central Universities

참고문헌

  1. Anbarasu, M., Kumar, S.B. and Sukumar, S. (2013), "Study on the effect of ties in the intermediate length Cold Formed Steel (CFS) columns", Struct. Eng. Mech., 46 (3), 323-335. https://doi.org/10.12989/sem.2013.46.3.323.
  2. Anbarasu, M. and Sukumar, S. (2014), "Influence of spacers on ultimate strength of intermediate length thin walled columns", Steel Compos. Struct., 16(4), 437-454. https://doi.org/10.12989/scs.2014.16.4.437.
  3. AISI (2007), North American specification for the design of coldformed steel structural members, Washington, DC, USA.
  4. Aslani, F. and Goel, S.C. (1991), "An analytical criterion for buckling strength of built-up compression members", Eng. J. AISC, 28(4), 159-168.
  5. AS/NZS No. 4600 (2005), Cold-formed Steel Structure, Sydney, Australia.
  6. Biggs, K.A., Ramseyer, C., Ree, S. and Kang, T.H.K. (2015), "Experimental testing of cold-formed built-up members in pure compression", Steel Compos. Struct, 18(6), 1331-1351. https://doi.org/10.12989/scs.2015.18.6.1331.
  7. Dabaon, M., Ellobody, E. and Ramzy, K. (2015), "Experimental investigation of built-up cold-formed steel section battened columns", Thin-Walled Struct., 92, 137-145. https://doi.org/10.1016/j.tws.2015.03.001.
  8. Dong, J., Wang, S.Q. and Lu, X. (2006), "Simulations of the hysteretic behavior of thin-wall cold-formed steel members under cyclic uniaxial loading", Struct. Eng. Mech., 24(3), 323-337. https://doi.org/10.12989/sem.2006.24.3.323.
  9. Eurocode 3 (2006), Design of steel structures-Part 1-3: General rules supplementary rules for cold-formed members and sheeting, BS EN 1993-1-3, Brussels.
  10. Georgieva, I., Schueremans, L. and Pyl, L. (2012), "Composed columns from cold-formed steel Z-profiles: Experiments and code-based predictions of the overall compression capacity", Eng. Struct., 37(4), 125-134. https://doi.org/10.1016/j.engstruct.2011.12.017.
  11. GB50018 (2002), Technical Code of Cold-formed Thin-wall Steel Structures, Beijing, China.
  12. GB/T228.1 (2010), Metallic materials: Tensile testing: part 1: Method of test at room temperature, Beijing, China.
  13. Heva, Y.B. and Mahendran, M. (2013), "Flexural-torsional buckling tests of cold-formed steel compression members at elevated temperatures", Steel Compos. Struct., 14(3), 205-227. https://doi.org/10.12989/scs.2013.14.3.205.
  14. Kripka, M. and Pravia, Z.M.C. (2013), "Cold-formed steel channel columns optimization with simulated annealing method", Struct. Eng. Mech., 48(3), 383-394. https://doi.org/10.12989/sem.2013.48.3.383.
  15. Li, Y.Q., Li, Y.L., Wang, S.K. and Shen, Y.Z. (2014), "Ultimate load-carrying capacity of cold-formed thin-walled columns with built-up box and I section under axial compression", Thin-Walled Struct., 79(3), 202-217. https://doi.org/10.1016/j.tws.2014.02.003.
  16. Miller, T.H. and Pekoz, T. (1993), "Behavior of cold-formed steel wall stub assemblies", J. Struct. Eng., 119(2) 641-651. https://doi.org/10.1061/(ASCE)0733-9445(1993)119:2(641)
  17. Muthuraj, H., Sekar, S.K., Mahendran, M. and Deepak, O.P. (2017), "Post buckling mechanics and strength of cold-formed steel columns exhibiting Local-Distortional interaction mode failure", Struct. Eng. Mech., 64(5), 621-640. https://doi.org/10.12989/sem.2017.64.5.621.
  18. Peters, G.K. (2003), "An investigation of the effects of fastener spacing in build-up cold-formed steel compression members", M.Sc. Dissertation, University of Dalhousie, Canada.
  19. Piyawat, K., Ramseyer, C. and Kang, T.H.K. (2013), "Development of an Axial Load Capacity Equation for Doubly-Symmetric Built-Up Cold-Formed Sections," J. Struct. Eng., 139(12), 04013008. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000780
  20. Schafer, B.W. (2012), CUFSM4.05: Finite strip buckling analysis of thin-walled members, Johns Hopkins University, Baltimore, U.S.A. http://www.ce.jhu.edu/bschafer/cufsm.
  21. Stone, T.A. and La Boube, R.A. (2005), "Behavior of cold-formed steel built-up I-sections", Thin-Walled Struct., 43(12), 1805-1817. https://doi.org/10.1016/j.tws.2005.09.001.
  22. Whittle, J. and Ramseyer, C. (2009), "Buckling capacities of axially loaded, cold-formed, built-up C-channels", Thin-Walled Struct., 47(2), 190-201. https://doi.org/10.1016/j.tws.2008.05.014.
  23. Young, B. and Chen, J. (2008), "Column tests of cold-formed steel non-symmetric lipped angle sections", J. Constr. Steel Res., 64(7), 808-815. https://doi.org/10.1016/j.jcsr.2008.01.021.
  24. Young, B. and Rasmussen, K.J.R. (1998), "Tests of fixed-ended plain channel columns", J. Struct. Eng., 124(2), 131-139. https://doi.org/10.1061/(ASCE)0733-9445(1998)124:2(131)
  25. Yu, W.W. (2000), Cold Formed Steel Design, 3rd Edition, John Wiley & Sons Inc., New York, NY, USA.
  26. Zandonini, R. (1985), "Stability of compact built-up struts: experimental investigation and numerical simulation", Constr. Met., 4, 288.
  27. Zhang, J.H. and Young, B. (2015), "Numerical investigation and design of cold-formed steel built-up open section columns with longitudinal stiffeners", Thin-Walled Struct., 89, 178-191. https://doi.org/10.1016/j.tws.2014.12.011.
  28. Zhou, L.H. (2007), "Experimental and theoretical research on high strength cold-formed thin-walled steel stub columns under compression", M.Sc. Dissertation, Chang'an University, China.
  29. Zhou, W.B. and Jiang, L.Z. (2017), "Distortional buckling of coldformed lipped channel columns subjected to axial compression", Steel Compos. Struct., 23(3), 331-338. http://doi.org/10.12989/scs.2017.23.3.331.

피인용 문헌

  1. Parametric study and Improved design guidelines of CFS battened built-up columns vol.40, pp.5, 2019, https://doi.org/10.12989/scs.2021.40.5.733