DOI QR코드

DOI QR Code

The Effects of Hot Water Supply on Energy Consumption for Floor Radiant Heating System

바닥복사 난방시스템의 공급온수특성에 따른 에너지 소비특성 연구

  • Received : 2019.10.28
  • Accepted : 2019.11.27
  • Published : 2019.12.01

Abstract

In this study, the effect of hot water supply flow rates on energy consumption for radiant floor heating system in apartment were researched by computer simulation. The parametric study of different hot water supply flow rates was done with regard to energy performance and control characteristics, respectively. Also the effect of different hot water supply flow rates on the hot water supply temperatures is studied. As a result, energy consumption were reduced but the response time is increased by reducing the supply flow rate. And energy consumption can be saved by adjusting the hot water supply temperatures with different supply flow rates.

Keywords

References

  1. Song, J. Y. and Ahn, B. C., 2016, Simulation study for control strategies of indoor air temperature in floor radiant heating system, Korea Society of Geothermal Energy Engineers, Vol. 12, No. 4, pp. 21-26. https://doi.org/10.17664/ksgee.2016.12.4.021
  2. S. H. Cho and M. Zaheer-uddin, 2003, Predictive control of intermittently operated radiant floor heating system, Energy Conversion and Management, 44, pp. 1333-1342. https://doi.org/10.1016/S0196-8904(02)00116-4
  3. Ahn, B. C. and Song, J. Y., 2010, Control cha-racteristics and heating performance analysis of automatic thermostatic valves for floor rad-iant heating system in residential apartment, Energy, 35, pp. 1615-1624. https://doi.org/10.1016/j.energy.2009.11.007
  4. S. Sattari and B. Farhanieh, 2006, A parametric study on radiant floor heating system perform-ance, Renewable Energy, No. 31, pp. 1617-1626.
  5. Ahn, B. C., 2018, The Effects of Hot Water Supply Temperature on Indoor Thermal Characteristics for Floor Radiant Heating System, Korea Society of Geothermal Energy Engineers, Vol. 14, No. 4, pp. 13-19.