DOI QR코드

DOI QR Code

Seismic performance of secondary systems housed in isolated and non-isolated building

  • Kumar, Pardeep (Civil Engineering Department, National Institute of Technology) ;
  • Petwal, Sandeep (Civil Engineering Department, National Institute of Technology)
  • Received : 2018.06.05
  • Accepted : 2019.02.24
  • Published : 2019.04.25

Abstract

The concept of base isolation for equipment is well known. Its application in buildings and structures is rather challenging. Introduction of horizontal flexibility at the base helps in proper energy dissipation at the base level thus reducing the seismic demand of the super structure to be considered during design. The present study shows the results of a series of numerical simulation studies on seismic responses of secondary system (SS) housed in non-isolated and base-isolated primary structures (PS) including equipment-structure interactions. For this study the primary structure consists of two similar single bay three-store reinforced cement concrete (RCC) Frame building, one non-isolated with conventional foundation and another base isolated with Lead plug bearings (LPB) constructed at IIT Guwahati, while the secondary system is modeled as a steel frame. Time period of the base isolated building is higher than the fixed building. Due to the presence of isolator, Acceleration response is significantly reduced in both (X and Y) direction of Building. It have been found that when compared to fixed base building, the base isolated building gives better performance in high seismic prone areas.

Keywords

References

  1. Aiken, I.D. (1996), "Passive energy dissipation- hardware and applications", Proceeding Las Angles County and SEAOSC Symposium on Passive Energy Dissipation Systems for New and Existing Buildings, 1-24.
  2. Aiken, I.D. (1999), "Observed behaviour of seismically isolated buildings", J. Struct. Eng., 125, 955-964. https://doi.org/10.1061/(ASCE)0733-9445(1999)125:9(955)
  3. Aiken, I.D., Nims, D.K., Whittaker, A.S. and Kelly, J.M. (1993), "Testing of passive energy dissipation systems", Earthq. Spectra, 9(3), 1-36.
  4. Bezerra, L.M. and Carneiro, R.C. (2003), "A numerical evaluation of anti-vibration mechanisms applied to frame structures under earthquake", 17th International Conference on Structural Mechanics in Reactor Technology (SMIRT 17), 13(2), 1-8.
  5. Cancellara, D. and Angeli, F.D. (2012), "Dynamic nonlinear analysis of an hybrid base isolation system with viscous dampers and friction sliders in parallel", Appl. Mech. Mater., 234, 96-101. https://doi.org/10.4028/www.scientific.net/AMM.234.96
  6. Cancellara, D. and Angelis, F.D. (2012), "Hybrid base isolation system with friction sliders and viscous dampers in parallel: comparative dynamic nonlinear analysis with traditional fixed base structure", Adv. Mater. Res., 594-597, 1771-1782. https://doi.org/10.4028/www.scientific.net/AMR.594-597.1771
  7. Cancellara, D. and Angelis, F.D. (2016), "Assessment and dynamic nonlinear analysis of different base isolation systems for a multi-storey RC building irregular in plan", Comput. Struct., 180, 74-88. https://doi.org/10.1016/j.compstruc.2016.02.012
  8. Chen, Y. and Soong, T.T. (1988), "State-of-the-art- review: seismic response of secondary systems", Eng. Struct., 10, 218-228. https://doi.org/10.1016/0141-0296(88)90043-0
  9. Deb, S.K. (2004), "Seismic base isolation - An overview", Curr. Sci., 87, 1426-1430.
  10. Deb, S.K., Paul, D.K. and Thakkar, S.K. (1997), "Simplified nonlinear analysis of base isolated buildings subjected to general plane motion", Eng. Comput., 14, 542-557. https://doi.org/10.1108/02644409710170384
  11. Dubey, P.N., Reddy, G.R., Deb, S.K., Vaze, K.K., Ghosh, A.K. and Kushwaha, H.S. (2007), "Performance of base isolated RCC framed building under actual earthquake", Proceedings of the 1st Intl. Conf. on Earthquake Hazards and Management, Guwahati, India.
  12. Fan, F.G. and Ahmadi, G. (1992), "Seismic response of secondary system in base-isolated structures", Eng. Strut., 14(1), 35-48. https://doi.org/10.1016/0141-0296(92)90006-C
  13. Federal Emergency Management Agency, (FEMA)-306 (1998), Evaluation of Earthquake Damaged Concrete and Masonry Walls Buildings.
  14. Gur, S., Mishra, S.K. and Chakraborty, S. (2013), "Performance assessment of buildings isolated by shape-memory-alloy rubber bearing: comparison with elastomeric bearing under near-fault earthquakes", Struct. Control Hlth. Monit., 21(4), 449-465.
  15. IS: 456-2000 (2000), Plain and Reinforced Concrete-Code of Practice, Fourth Revision, Bureau of Indian Standards (BIS), New Delhi.
  16. Izumi Masanory (1988), "Base isolation and passive seismic response control", Proceedings of Ninth World Conference on Earthquake Engineering, VIII, 385-396.
  17. Jangid, R.S. (2010), "Stochastic response of building frames isolated by lead-rubber bearings", Struct. Control Hlth. Monit., 17, 1-22. https://doi.org/10.1002/stc.266
  18. Jangid, R.S. and Datta, T.K. (1995), "Seismic behaviour of baseisolated buildings: a state-of-the-art review", ICE: Struct. Build., 110(2), 186-203. https://doi.org/10.1680/istbu.1995.27599
  19. Jeon, B.G., Chang, S.J., Kim, S.W. and Kim, N.S. (2015), "Base isolation performance of a cone-type friction pendulum bearing system", Struct. Eng. Mech., 53(2), 227-248. https://doi.org/10.12989/sem.2015.53.2.227
  20. Jeon, B.G., Jang, S.J., Park, K.R. and Kim, N.S. (2011), "Seismic performance evaluation of cone-type friction pendulum bearing system", J. Earthq. Eng. Soc. Korea, 15(2), 23-33. https://doi.org/10.5000/EESK.2011.15.2.023
  21. Kelly, J.M. (1986), "Aseismic base isolation: review and bibliography", Soil Dyn. Earthq. Eng., 5, 202-216. https://doi.org/10.1016/0267-7261(86)90006-0
  22. Khechfe, H., Noori, M., Hou, Z., Kelly, J.M. and Ahmadi, G. (2002), "An experimental study on the seismic response of base-isolated secondary systems", J. Press. Ves. Technol., 124, 81-88. https://doi.org/10.1115/1.1445795
  23. Kikuchi, M. and Aiken, I.D. (1997), "An analytical hysteresis model for elastomeric seismic isolation bearings", Earthq. Eng. Struct. Dyn., 26(2), 1-17.
  24. Krishnamoorthy, A. (2013), "Effect of soil-structure interaction for a building isolated with FPS", Earthq. Struct., 4(3), 285-297. https://doi.org/10.12989/eas.2013.4.3.285
  25. Li, Y., Li, J., Li, W. and Samali, B. (2013), "Development and characterization of a magnetorheological elastomer based adaptive seismic isolator", Smart Mater. Struct., 22(3), 035005. https://doi.org/10.1088/0964-1726/22/3/035005
  26. Mallikarjun, P.V., Jagtap, P., Kumar, P. and Matsagar, V. (2015), "Performance of seismic base isolated building for secondary system protection under real earthquakes", Adv. Struct. Eng., II(Part XII), 1353-1363.
  27. Matsagar, V.A. and Jangid, R.S. (2004), "Influence of isolator characteristics on the response of base-isolates structures", Eng. Struct., 26, 1735-1749. https://doi.org/10.1016/j.engstruct.2004.06.011
  28. Mysliniaj, B., Gamble, S. and Sinclair, R. (2003), "Base isolation technologies for seismic protection of museum artifacts", The 2003 IAMFA Annual Conference in San Francisco, California. San Francisco, CA, IAMFA.
  29. Ortiz, N.A., Magluta, C. and Roitman, N. (2015), "Numerical and experimental studies of a building with roller seismic isolation bearings", Struct. Eng. Mech., 54(3), 475-489. https://doi.org/10.12989/sem.2015.54.3.475
  30. Paulson, T.J., Abrams, D.P. and Mayes, R.L. (1991), "Shaking table study of base isolation for masonry buildings", J. Struct. Eng., 117, 3315-3336. https://doi.org/10.1061/(ASCE)0733-9445(1991)117:11(3315)
  31. Rao Bhaskar, P. and Jangid, R.S. (2001), "Experimental study on base isolated structures", ISET J. Eearthq. Technol., 38(1), 1-15.
  32. Ryan, K.L. and Chopra, A.K. (2004), "Estimation of seismic demands on isolators based on nonlinear analysis", J. Struct. Eng., 130, 392-402. https://doi.org/10.1061/(ASCE)0733-9445(2004)130:3(392)
  33. Sackman, J.L. and Kelly, J.M. (1979), "Seismic analysis of internal equipment and components in structures", Eng. Struct., 1(4), 179-190. https://doi.org/10.1016/0141-0296(79)90045-2
  34. Sayed, M.A., Go, S., Cho, S.G. and Kim, D. (2015), "Seismic responses of base-isolated nuclear power plant structures considering spatially varying ground motions", Struct. Eng. Mech., 54(1), 169-188 https://doi.org/10.12989/sem.2015.54.1.169
  35. Sevket, A. (2012), "Investigation of effectiveness of double concave friction pendulum bearings", Comput. Concrete, 9(3), 195-213. https://doi.org/10.12989/cac.2012.9.3.195
  36. Shenton, H.W. and Lin, A.N. (1993), "Relative performance of fixed-base and base-isolated concrete frames", J. Struct. Eng., 119(10), 2952-2968. https://doi.org/10.1061/(ASCE)0733-9445(1993)119:10(2952)
  37. Singh, M.P. (1980), "Seismic design input for secondary systems", J. Struct. Eng., ASCE, 106(2), 505-517.
  38. Singh, M.P. (1988), "Seismic design of secondary systems", Prob. Eng. Mech., 3(3), 151-158. https://doi.org/10.1016/0266-8920(88)90027-6
  39. Wang, L., Oua, J., Liu, W. and Wang, S. (2013), "Full-scale tests and analytical model of the Teflon-based lead rubber isolation bearings", Struct. Eng. Mech., 48(6), 809-822. https://doi.org/10.12989/sem.2013.48.6.809
  40. Yang, Z. and Lam, E.S.S. (2015), "Seismic mitigation of an existing building by connecting to a base-isolated building with visco-elastic dampers", Struct. Eng. Mech., 53(1), 57-71. https://doi.org/10.12989/sem.2015.53.1.057