Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method

  • Lee, Suji ;
  • Hong, Seoung-Jin (Department of Prosthodontics, Kyung Hee University Dental Hospital) ;
  • Paek, Janghyun (Department of Prosthodontics, School of Dentistry, Kyung Hee University) ;
  • Pae, Ahran (Department of Prosthodontics, School of Dentistry, Kyung Hee University) ;
  • Kwon, Kung-Rock (Department of Prosthodontics, School of Dentistry, Kyung Hee University) ;
  • Noh, Kwantae (Department of Prosthodontics, School of Dentistry, Kyung Hee University)
  • 투고 : 2018.08.08
  • 심사 : 2019.01.21
  • 발행 : 2019.02.28

초록

PURPOSE. The accuracy of denture bases was compared among injection molding, milling, and rapid prototyping (RP) fabricating method. MATERIALS AND METHODS. The maxillary edentulous master cast was fabricated and round shaped four notches were formed. The cast was duplicated to ten casts and scanned. In the injection molding method, designed denture bases were milled from a wax block and fabricated using SR Ivocap injection system. Denture bases were milled from a pre-polymerized block in the milling method. In the RP method, denture bases were printed and post-cured. The intaglio surface of the base was scanned and surface matching software was used to measure inaccuracy. Measurements were performed between four notches and two points in the mid-palatal suture to evaluate inaccuracy. The palatine rugae resolution was evaluated. One-way analysis of variance was used for statistical analysis at ${\alpha}=.05$. RESULTS. No statistically significant differences in distances among four notches (P>.05). The accuracy of the injection molding method was lower than those of the other methods in two points of the mid-palatal suture significantly (P<.05). The degree of palatine rugae resolution was significantly higher in the injection molding method than that in other methods (P<.05). CONCLUSION. The overall accuracy of the denture base is higher in milling and RP method than the injection molding method. The degree of fine reproducibility is higher in the injection molding method than the milling or RP method.

키워드

참고문헌

  1. Kawara M, Komiyama O, Kimoto S, Kobayashi N, Kobayashi K, Nemoto K. Distortion behavior of heat-activated acrylic denture-base resin in conventional and long, low-temperature processing methods. J Dent Res 1998;77:1446-53. https://doi.org/10.1177/00220345980770060901
  2. Parvizi A, Lindquist T, Schneider R, Williamson D, Boyer D, Dawson DV. Comparison of the dimensional accuracy of injection-molded denture base materials to that of conventional pressure-pack acrylic resin. J Prosthodont 2004;13:83-9. https://doi.org/10.1111/j.1532-849X.2004.04014.x
  3. Darvell BW, Clark RK. The physical mechanisms of complete denture retention. Br Dent J 2000;189:248-52. https://doi.org/10.1038/sj.bdj.4800734
  4. Jacob RF. The traditional therapeutic paradigm: complete denture therapy. J Prosthet Dent 1998;79:6-13. https://doi.org/10.1016/S0022-3913(98)70186-6
  5. Jacobson TE, Krol AJ. A contemporary review of the factors involved in complete denture retention, stability, and support. Part I: retention. J Prosthet Dent 1983;49:5-15. https://doi.org/10.1016/0022-3913(83)90228-7
  6. Jacobson TE, Krol AJ. A contemporary review of the factors involved in complete dentures. Part II: stability. J Prosthet Dent 1983;49:165-72. https://doi.org/10.1016/0022-3913(83)90494-8
  7. Jacobson TE, Krol AJ. A contemporary review of the factors involved in complete dentures. Part III: support. J Prosthet Dent 1983;49:306-13. https://doi.org/10.1016/0022-3913(83)90267-6
  8. Pryor WJ. Injection molding of plastics for dentures. J Am Dent Assoc 1942;29:1400-8. https://doi.org/10.14219/jada.archive.1942.0201
  9. Huggett R, Zissis A, Harrison A, Dennis A. Dimensional accuracy and stability of acrylic resin denture bases. J Prosthet Dent 1992;68:634-40. https://doi.org/10.1016/0022-3913(92)90379-O
  10. Goodacre CJ, Garbacea A, Naylor WP, Daher T, Marchack CB, Lowry J. CAD/CAM fabricated complete dentures: concepts and clinical methods of obtaining required morphological data. J Prosthet Dent 2012;107:34-46. https://doi.org/10.1016/S0022-3913(12)60015-8
  11. Bidra AS, Taylor TD, Agar JR. Computer-aided technology for fabricating complete dentures: systematic review of historical background, current status, and future perspectives. J Prosthet Dent 2013;109:361-6. https://doi.org/10.1016/S0022-3913(13)60318-2
  12. Infante L, Yilmaz B, McGlumphy E, Finger I. Fabricating complete dentures with CAD/CAM technology. J Prosthet Dent 2014;111:351-5. https://doi.org/10.1016/j.prosdent.2013.10.014
  13. Maeda Y, Minoura M, Tsutsumi S, Okada M, Nokubi T. A CAD/CAM system for removable denture. Part I: Fabrication of complete dentures. Int J Prosthodont 1994;7:17-21.
  14. Matsuda T, Goto T, Yagi K, Kashiwabara T, Ichikawa T. Partdigitizing system of impression and interocclusal record for complete denture fabrication. J Prosthodont 2016;25:503-9. https://doi.org/10.1111/jopr.12375
  15. Kuesel AC, Graschew G, Hull WE, Lorenz W, Thielmann HW. 31P NMR studies of cultured human tumor cells. Influence of pH on phospholipid metabolite levels and the detection of cytidine 5'-diphosphate choline. NMR Biomed 1990;3:78-89. https://doi.org/10.1002/nbm.1940030206
  16. Wimmer T, Gallus K, Eichberger M, Stawarczyk B. Complete denture fabrication supported by CAD/CAM. J Prosthet Dent 2016;115:541-6. https://doi.org/10.1016/j.prosdent.2015.10.016
  17. Munari LS, Cornacchia TP, Moreira AN, Goncalves JB, De Las Casas EB, Magalhaes CS. Stress distribution in a premolar 3D model with anisotropic and isotropic enamel. Med Biol Eng Comput 2015;53:751-8. https://doi.org/10.1007/s11517-015-1289-4
  18. Goodacre BJ, Goodacre CJ, Baba NZ, Kattadiyil MT. Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques. J Prosthet Dent 2016;116:249-56. https://doi.org/10.1016/j.prosdent.2016.02.017
  19. McLaughlin JB, Ramos V Jr, Dickinson DP. Comparison of fit of dentures fabricated by traditional techniques versus CAD/CAM technology. J Prosthodont 2017 Nov 14.
  20. Johnson DL, Holt RA, Duncanson MG Jr. Contours of the edentulous palate. J Am Dent Assoc 1986;113:35-40. https://doi.org/10.14219/jada.archive.1986.0147
  21. Sykora O, Sutow EJ. Posterior palatal seal adaptation: influence of processing technique, palate shape and immersion. J Oral Rehabil 1993;20:19-31. https://doi.org/10.1111/j.1365-2842.1993.tb01511.x
  22. Johnson DL, Duncanson MG Jr. The plastic postpalatal denture seal. Quintessence Int 1987;18:457-62.
  23. Lee CJ, Bok SB, Bae JY, Lee HH. Comparative adaptation accuracy of acrylic denture bases evaluated by two different methods. Dent Mater J 2010;29:411-7. https://doi.org/10.4012/dmj.2009-105
  24. Steinmassl O, Dumfahrt H, Grunert I, Steinmassl PA. CAD/CAM produces dentures with improved fit. Clin Oral Investig 2018;22:2829-35. https://doi.org/10.1007/s00784-018-2369-2
  25. Schaefer O, Decker M, Wittstock F, Kuepper H, Guentsch A. Impact of digital impression techniques on the adaption of ceramic partial crowns in vitro. J Dent 2014;42:677-83. https://doi.org/10.1016/j.jdent.2014.01.016
  26. Ender A, Mehl A. Influence of scanning strategies on the accuracy of digital intraoral scanning systems. Int J Comput Dent 2013;16:11-21.
  27. Petrovic V, Gonzalez JVH, Ferrando OJ, Gordillo JD, Puchades JRB, Grinan LP. Additive layered manufacturing: sectors of industrial application shown through case studies. Int J Prod Res 2011;49:1061-79. https://doi.org/10.1080/00207540903479786
  28. Groth C, Kravitz ND, Jones PE, Graham JW, Redmond WR. Three-dimensional printing technology. J Clin Orthod 2014;48:475-85.
  29. Alharbi N, Osman R, Wismeijer D. Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations. J Prosthet Dent 2016;115:760-7. https://doi.org/10.1016/j.prosdent.2015.12.002
  30. Braian M, Jimbo R, Wennerberg A. Production tolerance of additive manufactured polymeric objects for clinical applications. Dent Mater 2016;32:853-61. https://doi.org/10.1016/j.dental.2016.03.020
  31. Allen S, Dutta D. On the computation of part orientation using support structures in layered manufacturing. Proceedings of the International Solid Freeform Fabrication Symposium; Austin, TX, 1994. p. 259-69.
  32. Plooij JM, Maal TJ, Haers P, Borstlap WA, Kuijpers-Jagtman AM, Berge SJ. Digital three-dimensional image fusion processes for planning and evaluating orthodontics and orthognathic surgery. A systematic review. Int J Oral Maxillofac Surg 2011;40:341-52. https://doi.org/10.1016/j.ijom.2010.10.013
  33. Revilla-Leon M, Ozcan M. Additive manufacturing technologies used for processing polymers: Current status and potential application in prosthetic dentistry. J Prosthodont 2018 Apr 22.
  34. Srinivasan M, Cantin Y, Mehl A, Gjengedal H, Muller F, Schimmel M. CAD/CAM milled removable complete dentures: an in vitro evaluation of trueness. Clin Oral Investig 2017;21:2007-19. https://doi.org/10.1007/s00784-016-1989-7
  35. Puebla K, Arcaute K, Quintana R, Wicker RB. Effects of environmental conditions, aging, and build orientations on the mechanical properties of ASTM type I specimens manufactured via stereolithography. Rapid Prototyp J 2012;18:374-88. https://doi.org/10.1108/13552541211250373

피인용 문헌

  1. 전통적 방식과 CAD/CAM을 이용한 양악 총의치 수복 증례 vol.57, pp.3, 2019, https://doi.org/10.4047/jkap.2019.57.3.296
  2. 적층가공과 절삭가공으로 제작한 의치상과 직접 첨상용 레진 간의 인장결합강도 비교 vol.58, pp.3, 2019, https://doi.org/10.4047/jkap.2020.58.3.177
  3. 3D 프린팅용 광경화 수지를 사용하여 제작한 의치상용 인공치아의 항온수조 침적에 따른 변형률 비교 분석 vol.42, pp.3, 2020, https://doi.org/10.14347/jtd.2020.42.3.202
  4. 3D printed complete removable dental prostheses: a narrative review vol.20, pp.1, 2019, https://doi.org/10.1186/s12903-020-01328-8
  5. 공기중과 수중에서 보관한 총의치 의치상의 체적변화에 대한 비교연구 vol.59, pp.1, 2019, https://doi.org/10.4047/jkap.2021.59.1.18
  6. 임플란트용 플라스틱 트레이를 이용하여 하악 흡착의치를 제작하는 방법 vol.59, pp.1, 2021, https://doi.org/10.4047/jkap.2021.59.1.36
  7. Effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing: An in vitro study vol.13, pp.1, 2019, https://doi.org/10.4047/jap.2021.13.1.24
  8. Evaluation of Denture Base Adaptation Fabricated Using Conventional, Subtractive, and Additive Technologies: A Volumetric Micro‐Computed Tomography Analysis vol.30, pp.3, 2019, https://doi.org/10.1111/jopr.13326
  9. CAD/CAM Complete Denture Systems and Physical Properties: A Review of the Literature vol.30, pp.suppl2, 2019, https://doi.org/10.1111/jopr.13243
  10. Digitally Fabricated Removable Complete Denture Clinical Workflows using Additive Manufacturing Techniques vol.30, pp.suppl2, 2019, https://doi.org/10.1111/jopr.13318
  11. Accuracy Evaluation of Additively and Subtractively Fabricated Palatal Plate Orthodontic Appliances for Newborns and Infants-An In Vitro Study vol.14, pp.15, 2019, https://doi.org/10.3390/ma14154103
  12. Evaluation of Dimensional Changes during Postcuring of a Three-Dimensionally Printed Denture Base According to the Curing Time and the Time of Removal of the Support Structure: An In Vitro Study vol.11, pp.21, 2019, https://doi.org/10.3390/app112110000
  13. Effect of additive manufacturing method and build angle on surface characteristics and Candida albicans adhesion to 3D printed denture base polymers vol.116, 2019, https://doi.org/10.1016/j.jdent.2021.103889