DOI QR코드

DOI QR Code

Development of wearable Range of Motion measurement device capable of dynamic measurement

  • Song, Seo Won (Dept. of Medical IT Marketing, Eulji University) ;
  • Lee, Minho (Dept. of Food Technology and Services, Eulji University) ;
  • Kang, Min Soo (Dept. of Medical IT, Eulji University)
  • Received : 2019.11.06
  • Accepted : 2019.11.18
  • Published : 2019.12.31

Abstract

In this paper, we propose the miniaturization size of wearable Range of Motion(ROM) and a system that can be connected with smart devices in real-time to measure the joint movement range dynamically. Currently, the ROM of the joint is directly measured by a person using a goniometer. Conventional methods are different depending on the measurement method and location of the measurement person, which makes it difficult to measure consistently and may cause errors. Also, it is impossible to measure the ROM of joints in real-life situations. Therefore, the wearable sensor is attached to the joint to be measured to develop a miniaturize size ROM device that can measure the range of motion of the joint in real-time. The sensor measured the resistance value changed according to the movement of the joint using a load cell. Also, the sensed analog values were converted to digital values using an Analog to Digital Converter(ADC). The converted amount can be transmitted wireless to the smart device through the wearable sensor node. As a result, the developed device can be measured more consistently than the measurement using the goniometer, communication with IoT-based smart devices, and wearable enables dynamic observation. The developed wearable sensor node will be able to monitor the dynamic state of rehabilitation patients in real-time and improve the rapid change of treatment method and customized treatment.

Keywords

References

  1. Spilker B., Quality of life and pharmacoeconomics in clinical trials 2nd edition, Lippincott-Raven, p.1-10, 1996. DOI: https://doi.org/10.1016/S0197-2456(97)82191-5
  2. J.W. Kim, B.K. Park, J.H. Hong and G.M. Eom, "The Trend and Prospect of Silver/Rehabilitation Engineering", KIC News, Vol.11, No.2, pp.11-23, April 2008.
  3. W.S. Hong and G.W. Kim, "Reliability of measurement devices for measuring the ankle joint motion.", The Journal of Korean Academy of Orthopedic Manual Therapy, Vol.15, No.1, pp.1-8, June 2009.
  4. Y.J. MOON, S.H. LEE, J.H. BACK, J.K, LEE and G.B. LEE. "Development of Posture Evaluation System through Digital Recognition Method", Korean Journal of Sport Biomechanics, Vol. 14, No. 3, pp. 49-65, December 2004. DOI: https://doi.org/10.5103/KJSB.2004.14.3.049
  5. Megan M. Konor, Sam Morton, Joan M. Eckerson, and Terry L. Grindstaff, "Reliability of Three Measures of Ankle Dorsiflexion Range of Motion", The International Journal of Sports Physical Therapy, vol. 7, no.3, pp.279-287, June 2012.
  6. Naver terms, Range of Motion, Web URL: https://terms.naver.com/entry.nhn?docId=487420&cid=60408&categoryId=55558
  7. M.S. Kang, "Development ROM Measurement Device capable of IoT-based Real-time Monitoring for Rehabilitation Patients." The Journal of The Institute of Internet, Broadcasting and Communication, Vol.18, No.4, pp.111-116, August 2018. DOI: https://doi.org/10.7236/JIIBC.2018.18.4.111
  8. Barlow. D.H and Durand, V.M, "Abnormal psychology: An integrative approach", Belmont, CA, Wadsworth Cengage Learning, pp.331, 2009.
  9. Wikipedia, Biofeedback, Web URL: https://en.wikipedia.org/wiki/Biofeedback
  10. T.G. Yun and G.S. Yi, "Application of Random Forest Algorithm for the Decision Support System of Medical Diagnosis with the Selection of Significant Clinical Test", The transactions of The Korean Institute of Electrical Engineers, vol.57, no.6, pp.1058-1062, June 2008.
  11. M.H. Kang, J.Y. Yoon, J.L. Yang, J.H. Jang, D.H. Jung and J.S. Oh, "The Effect of Visual Biofeedback on EMG Activity of Trunk Muscles and Endurance Holding Time for Correct Position During Whole-Body Tilt Exercise", Physical Therapy Korea, Vol.18, No.1, pp.9-17, February 2011.
  12. M.S. Kang, C.H. Ihm, Y.G. Jung and M.H. Lee, "Development of IoT-based real-time Toxic Chemical Management System", The Journal of The Institute of Internet, Broadcasting and Communication, Vol.16, No.5, pp.143-149, October 2016. DOI: https://doi.org/10.7236/JIIBC.2016.16.5.143
  13. H.J. Lee, H.T. Lee and H.S. Shin, "A Study on Ubiquitous Sensor Network Technologies", The Journal of the Korea institute of electronic communication sciences, Vol.4, No.1, pp.70-77, March 2009.
  14. T.G. Lee, "Biometric information database and service modeling in digital patch system", International Journal of Advanced Smart Convergence, Vol.7, No.4, pp.161-168, December 2018. DOI: https://doi.org/10.7236/IJASC.2018.7.4.161
  15. L.M. Borges, N. Barroca, F. Velez and A. Lebres, "Smart-clothing: Wireless flex sensor belt network for foetal health monitoring", 3rd International Conference on Pervasive Computing Technologies for Healthcare, IEEE, pp.1- 4, August 2009. DOI: https://doi.org/10.4108/ICST.PERVASIVEHEALTH2009.6028