참고문헌
- Jemt T, Rubenstein JE, Carlsson L, Lang BR. Measuring fit at the implant prosthodontic interface. J Prosthet Dent 1996;75:314-325 https://doi.org/10.1016/S0022-3913(96)90491-6
- Jimbo R, Halldin A, Janda M, Wennerberg A, Vandeweghe S. Vertical fracture and marginal bone loss of internal-connection implants: a finite element analysis. Int J Oral Maxillofac Implants 2013;28:e171-176 https://doi.org/10.11607/jomi.3052
- Cha HS, Kim YS, Jeon JH, Lee JH. Cumulative survival rate and complication rates of single-tooth implant; Focused on the coronal fracture of fixture in the internal connection implant. J Oral Rehabil 2013;40:595-602 https://doi.org/10.1111/joor.12065
- Branemark P. Osseointegration and its experimental background. J Prosthet Dent 1983;50:399-410 https://doi.org/10.1016/S0022-3913(83)80101-2
- Watanabe F, Uno I, Hata Y, Neuendorff G, Kirsch A. Analysis of stress distribution in a screw-retained implant prosthesis. Int J Oral Maxillofac Implants 2000;15:209-218
- Jemt T, Book K. Prosthesis misfit and marginal bone loss in edentulous implant patients. Int J Oral Maxillofac Implants 1996;11:620-625
- Kosyfaki P, del Pilar Pinilla Martin M, Strub JR. Relationship between crowns and the periodontium: a literature update. Quintessence Int 2010;41:109-126.
- Katsoulis J, Takeichi T, Sol Gaviria A, Peter L, Katsoulis K. Misfit of implant prosthese and its impact on clinical outcomes. Definition, assessment and a systematic review of the literature. Eur J Oral Implantol 2017;10:121-138
- Sharkey S, Kelly A, Houston F, O'Sullivan M, Quinn F, O'connell B. A Radiographic analysis of implant component misfit. Int J oral Maxillofac Implants 2011;26:807-815
- Hayashi M, Watts DC, Ebisu S, Wilson NH. Influence of vision on the evaluation of marginal discrepancies in restorations. Oper Dent 2005;30:598-601
- Hayashi M, Wilson NH, Ebisu S, Wattts DC. Influence of explorer tip diameter in identifying restoration margin discrepancies. J Dent 2005;33:669-674 https://doi.org/10.1016/j.jdent.2005.01.006
- Kan JY, Rungcharassaeng K, Bohsali K, Goodacre CJ, Lang BR. Clinical methods for evaluating implant framework fit. J Prosthet Dent 1999;81:7-13 https://doi.org/10.1016/S0022-3913(99)70229-5
- Jemt T. Failures and complications in 391 consecutively inserted fixed prostheses supported by Branemark implant in the edentulous jaw: a study of treatment from the time of prostheses placement to the first annual check up. Int J Oral Maxillofac Implants 1991;6:270-276.
- Jemt T, Lie A. Accuracy of implant-supported prostheses in the edentulous jaw: analysis of precision of fit between cast gold-alloy frameworks and master casts by means of a three dimensional photogrammetric technique. Clin Oral Implants Res 1995;6:172-180 https://doi.org/10.1034/j.1600-0501.1995.060306.x
- Abduo J, Bennani V, Waddell N, Lyons K, Swain M. Assessing the fit of implant fixed prostheses: A critical review. Int J Oral Maxillofac Implants 2010;25:506-515
- Lee JI, Lee Y, Kim YL, Cho HW. Effect of implant number and distribution on load transfer in implant-supported partial fixed dental prostheses for the anterior maxilla: A photoelastic stress analysis study. J Prosthet Dent 2016;115:161-169 https://doi.org/10.1016/j.prosdent.2015.08.021
- Lencioni KA, Macedo AP, Silveira Rodrigues RC, Ribeiro RF, Almeida RP. Photoelastic comparison of as-cast and laser-welded implant frameworks. J Prosthet Dent 2015;114:652-659 https://doi.org/10.1016/j.prosdent.2015.06.005
- Lee JI, Lee Y, Kim NY, Kim YL, Cho HW. A photoelastic stress analysis of screw- and cementretained implant prostheses with marginal gaps. Clin Implant Dent Relat Res 2013;15:735-749
- de Torres EM, Barbosa GA, Bernardes SR, de Mattos Mda G, Ribeiro RF. Correlation between vertical misfits and stresses transmitted to implants from metal frameworks. J Biomech 2011;44:1735-1739 https://doi.org/10.1016/j.jbiomech.2011.03.032
- Termeie D, Klokkevold PR, Caputo AA.. Effect of implant diameter and ridge dimension on stress distribution in mandibular first molar siters-A photoelastic study. J Oral Implantol 2015;41:e165-173 https://doi.org/10.1563/aaid-joi-D-14-00008
- Geng JP, Tan KB, Liu GR. Application of finite element analysis in implant dentistry: A review of the literature. J Prosthet Dent 2001;85:585-598 https://doi.org/10.1067/mpr.2001.115251
- Kunavisarut C, Lang LA, Stoner BR, Felton DA. Finite element analysis on dental implant-supported prostheses without passive fit. J Prosthodont 2002;11:30-40
- Assuncao WG, Gomes EA, Rocha EP, Delben JA. Three-dimensional finite element analysis of vertical and angular misfit in implant-supported fixed prostheses. Int J Oral Maxillofac Implants 2011;26:788-796
- Dos Santos MB, Zen BM, Bacchi A. Effect of vertical misfit and clip material on stress distribution of overdentures under masticatory loading. Med Biol Eng Comput 2016;54:1515-1521 https://doi.org/10.1007/s11517-015-1426-0
- Winter W, Taylor TD, Karl M. Bone adaptation induced by non-passively fitting implant superstructures: A finite element analysis based on in vivo strain measurements. Int J Oral Maxillofac Implants 2011;26:1288-1295
- Brosh T, Pilo R, Sudai D. The influence of abutment angulation on strains and stresses along the implant/bone interface: Comparison between two experimental techniques. J Prosthet Dent 1998;79:328-334 https://doi.org/10.1016/S0022-3913(98)70246-X
- Abduo J, Swain M. Influence of vertical misfit of titanium and zirconia frameworks on peri-implant strain. Int J Oral Maxillofac Implants 2012;27:529-536
- De Vasconcellos DK, Ozcan M, Maziero Volpato CA, Bottino MA, Yener ES. Strain gauge analysis of the effect of porcelain firing simulation on the prosthetic misfit of implant-supported frameworks. Implant Dent 2012;21:225-229 https://doi.org/10.1097/ID.0b013e3182566e59
- Tahmaseb A, Mercelis P, de Clerck R, Wismeijer D. Optical scan analysis to detect minor misfit on implant-supported superstructures. Int J Oral Maxillofac Implants 2011;26:1344-1350
- Nascimento Cd, Ikeda LN, Pita MS, Pedroso e Silva RC, Pedrazzi V, Albuquerque RF, Ribeiro RF. Marginal fit and microbial leakage along the implant-abutment interface of fixed partial prosthesis: An in vitro analysis using checkerboard DNA-DNA hybridization. J Prosthet Dent 2015;114:831-838 https://doi.org/10.1016/j.prosdent.2015.05.009
- Teixeira W, Ribeiro RF, Sato S, Pedrazzi V. Microleakage into and from two-stage implants: An in vitro comparative study. Int J Oral Maxillofac Implants 2011;26:56-62
- Piattelli A, Scarano A, Paolantonio M, Assenza B, Leghissa GC, Di Bonaventura G, Catamo G, Piccollomini R. Fluids and microbial penetration in the internal part of cement-retained versus screwretained implant-abutment connections. J Periodontol 2001;72:1146-1150 https://doi.org/10.1902/jop.2000.72.9.1146
- do Nascimento C, Miani PK, Pedrazzi V, Goncalves RB, Ribeiro RF, Faria AC, Macedo AP, de Albuquerque RF Jr. Leakage of saliva through the implant-abutment interface: in vitro evaluation of three different implant connections under unloaded and loaded conditions. Int J Oral Maxillofac Implants 2012;27:551-560
- Lie A, Jemt T. Photogrammetric measurements of implant positions. Description of a technique to determine the fit between implants and superstructures. Clin Oral Implants Res;5:30-36
- Jemt T, Lekholm U. Measurements of bone and frame-work deformations induced by misfit of implant superstructures. A pilot study in rabbits. Clin Oral Implants Res 1998;9:272-280 https://doi.org/10.1034/j.1600-0501.1998.090408.x
- Chia VA, Esguerra RJ, Teoh KH, Teo JW, Wong KM, Tan KB. In vitro three-dimensional accuracy of digital implant impressions: The effect of implant angulation. Int J Oral Maxillofac Implants 2017;32:313-321 https://doi.org/10.11607/jomi.5087
- Geramipanah F, Sahebi M, Davari M, Hajimahmoudi M, Rakhshan V. Effects of impression levels and trays on the accuracy of impressions taken from angulated implants. Clin Oral Implants Res 2015;26:1098-1105 https://doi.org/10.1111/clr.12410
- Eliasson A, Wennerberg A, Johansson A, Ortorp A, Jemt T. The precision of fit of milled titanium implant frameworks in the edentulous jaw. Clin Implant Dent Relat Res 2010;12:81-90
- Alvarez A, Lafita P, de Lianos H, Gago A, Brizuela A, Ellacuria JJ. A comparison of two soldering techniques on the misfit of bar-retained implantsupported overdentures. J Prosthodont 2014;23:163-170 https://doi.org/10.1111/jopr.12083
- Spazzin AO, Bacchi A, Trevisani A, Farina AP, Dos Santos MB. Fit analysis of defferent framework fabrication techniques for implant-supported partial prostheses. Int J Prosthodont 2016;29:351-353 https://doi.org/10.11607/ijp.4542
- Katsoulis J, Muller P, Mericske-Stern R, Blatz MB. CAD/CAM fabrication accuracy of long- vs. shortspan implant-supported FDPs. Clin Oral Implants Res 2015;26:245-249
- Katsoulis J, Mericske-Stren R, Rotkina L, Zbaren C, Enkling N, Blatz MB. Precision of fit of implantsupported screw-retained 10-unit computer-aided - designed and computer-aided-manufactured frameworks made from zirconium dioxide and titanium: an in vitro study. Clin Oral Implants Res 2015;26:44-49
- Pauwels R, Araki K, Siewerdsen JH, Thongvigitmanee SS. Technical aspects of dental CBCT: state of the art. Dentomaxillofac Radiol 2015;44:20140224 https://doi.org/10.1259/dmfr.20140224
- Rodrigues SA, Presotto AGC, Barao VAR, Consani RLX, Nobilo MAA, Mesquita MF. The role of welding techniques in the biomechanical behavior of implant-supported prostheses. Mater Sci Eng C Mater Biol Appl 2017;78:435-442 https://doi.org/10.1016/j.msec.2017.04.090
- Meleo D, Baggi L, Di Girolamo M, Di Carlo F, Pecci R, Bedini R. Fixture-abutment connection surface and micro-gap measurements by 3D micro-tomographic technique analysis. Ann Ist Super Sanita 2012;48:53-58
- Blum K, Wiest W, Fella C, Balles A, Dittmann J, Rack A, Maier D, Thomann R, Spies BC, Kohal RJ, Zabler S, Nelson K. Fatigue induced changes in conical implant-abutment connections. Dent Mater 2015;11:1415-1426
- Rack A, Rack T, Stiller M, Riesemeier H, Zabler S, Nelson K. In vitro synchrotron-based radiography of micro-gap formation at the implant-abutment interface of two-piece dental implants. J Synchrotron Radiat 2010;17:289-294 https://doi.org/10.1107/S0909049510001834