과제정보
연구 과제 주관 기관 : 산업통상자원부
참고문헌
- Adell R, Eriksson B, Lekholm U, Branemark P-I, Jemt T. A long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. International Journal of Oral & Maxillofacial Implants 1990; Apr:347-359
- Branemark P-I, Breine U, Adell R, Hansson B, Lindstrom J, Ohlsson A. Intra-osseous anchorage of dental prostheses: I. Experimental studies. Scandinavian journal of plastic and reconstructive surgery 1969;3:81-100. https://doi.org/10.3109/02844316909036699
- Lee JS, Kim HM, Kim CS, Choi SH, Chai JK, Jung UW. Long-term retrospective study of narrow implants for fixed dental prostheses. Clinical oral implants research 2013;24:847-852. https://doi.org/10.1111/j.1600-0501.2012.02472.x
- Merheb J, Quirynen M, Teughels W. Critical buccal bone dimensions along implants. Periodontology 2000 2014;66:97-105. https://doi.org/10.1111/prd.12042
- Fu J-H, Wang H-L. Horizontal bone augmentation: the decision tree. International Journal of Periodontics & Restorative Dentistry 2011;3:428-436
- Zinsli B, Sagesser T, Mericske E, Mericske-Stern R. Clinical evaluation of small-diameter ITI implants: a prospective study. International Journal of Oral & Maxillofacial Implants 2004;19:92-99
- Arisan V, Bolukbasi N, Ersanli S, Ozdemir T. Evaluation of 316 narrow diameter implants followed for 5-10 years: a clinical and radiographic retrospective study. Clinical oral implants research 2010;21:296-307. https://doi.org/10.1111/j.1600-0501.2009.01840.x
- Buser D, Arx T. Surgical procedures in partially edentulous patients with ITI implants. Clinical Oral Implants Research 2000;11:83-100.
- Romeo E, Lops D, Amorfini L, Chiapasco M, Ghisolfi M, Vogel G. Clinical and radiographic evaluation of small?diameter (3.3-mm) implants followed for 1-7 years: a longitudinal study. Clinical oral implants research 2006;17:139-148. https://doi.org/10.1111/j.1600-0501.2005.01191.x
- Anchieta RB, Baldassarri M, Guastaldi F, et al. Mechanical property assessment of bone healing around a titanium-zirconium alloy dental implant. Clinical implant dentistry and related research 2014;16:913-919. https://doi.org/10.1111/cid.12061
- Kobayashi E, Matsumoto S, Yoneyama T, Hamanaka H. Mechanical properties of the binary titanium-zirconium alloys and their potential for biomedical materials. Journal of Biomedical Materials Research Part A 1995;29:943-950. https://doi.org/10.1002/jbm.820290805
- Thoma DS, Jones AA, Dard M, Grize L, Obrecht M, Cochran DL. Tissue integration of a new titanium?zirconium dental implant: a comparative histologic and radiographic study in the canine. Journal of periodontology 2011;82:1453-1461. https://doi.org/10.1902/jop.2010.100737
- Chang Y-Y, Kim S-H, Park K-O, Yun J-H. Evaluation of a Reverse-Tapered Design on the Osseointegration of Narrow-Diameter Implants in Beagle Dogs: A Pilot Study. The International journal of oral & maxillofacial implants 2016;31:611-620.
- Chang YY, Kim SH, Park KO, Yun JH. Effect of microthreads on coronal bone healing of narrow?diameter implants with reverse?tapered design in beagle dogs. Clinical Oral Implants Research 2017;31:611-620
- Abuhussein H, Pagni G, Rebaudi A, Wang HL. The effect of thread pattern upon implant osseointegration. Clinical oral implants research 2010;21:129-136. https://doi.org/10.1111/j.1600-0501.2009.01800.x
- Abrahamsson I, Berglundh T. Tissue characteristics at microthreaded implants: an experimental study in dogs. Clinical implant dentistry and related research 2006;8:107-113. https://doi.org/10.1111/j.1708-8208.2006.00016.x
- Hansson S. The implant neck: smooth or provided with retention elements. A biomechanical approach. Clinical oral implants research 1999;10:394-405. https://doi.org/10.1034/j.1600-0501.1999.100506.x
- Hudieb MI, Wakabayashi N, Kasugai S. Magnitude and direction of mechanical stress at the osseointegrated interface of the microthread implant. Journal of periodontology 2011;82:1061-1070. https://doi.org/10.1902/jop.2010.100237
- Bratu EA, Tandlich M, Shapira L. A rough surface implant neck with microthreads reduces the amount of marginal bone loss: a prospective clinical study. Clinical oral implants research 2009;20:827-832. https://doi.org/10.1111/j.1600-0501.2009.01730.x
- Park J-W, Park K-B, Suh J-Y. Effects of calcium ion incorporation on bone healing of Ti6Al4V alloy implants in rabbit tibiae. Biomaterials 2007;28:3306-3313. https://doi.org/10.1016/j.biomaterials.2007.04.007
- Suh JY, Jeung OC, Choi BJ, Park JW. Effects of a novel calcium titanate coating on the osseointegration of blasted endosseous implants in rabbit tibiae. Clinical oral implants research 2007;18:362-369. https://doi.org/10.1111/j.1600-0501.2006.01323.x
- Balubi TJ. An analysis and management of fractured implants: a clinical report. Int J Oral Maxillofac Implants 1996;11:660-666
- Becker CM, Kaiser DA. Surgical guide for dental implant placement. The Journal of prosthetic dentistry 2000;83:248-251. https://doi.org/10.1016/S0022-3913(00)80018-9
- Jung RE, Schneider D, Ganeles J, et al. Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants 2009;24:92-109.
- Moraschini V, Velloso G, Luz D, Barboza EP. Implant survival rates, marginal bone level changes, and complications in full-mouth rehabilitation with flapless computer-guided surgery: a systematic review and meta-analysis. International journal of oral and maxillofacial surgery 2015;44:892-901. https://doi.org/10.1016/j.ijom.2015.02.013
- Tahmaseb A, Wismeijer D, Coucke W, Derksen W. Computer technology applications in surgical implant dentistry: a systematic review. International Journal of Oral & Maxillofacial Implants 2014;29:25-42 https://doi.org/10.11607/jomi.2014suppl.g1.2
- Cassetta M, Di Mambro A, Giansanti M, Stefanelli L, Cavallini C. The intrinsic error of a stereolithographic surgical template in implant guided surgery. International journal of oral and maxillofacial surgery 2013;42:264-275. https://doi.org/10.1016/j.ijom.2012.06.010
- 김종은, 김남훈, 박지현, 심준성. 임플란트 가이드 수술을 위한 Planning 방식에 대한 고찰. 대한치과의사협회지 2016;54:108-122.