References
- R. Redus, M. Squillante, J.S. Gordon, P. Bennett, G. Entine, An imaging nuclear survey system, IEEE Trans. Nucl. Sci. 43 (3) (1996) 1827-1831. https://doi.org/10.1109/23.507230
- M. Woodring, D. Beddingfield, D. Souza, G. Entine, M. Squillante, J. Christian, A. Kogan, Advanced multi-dimensional imaging of gamma-ray radiation, Nucl. Instrum. Methods Phys. Res. A 505 (2003) 415-419. https://doi.org/10.1016/S0168-9002(03)01111-2
- W. Lee, G. Cho, Pinhole collimator design for nuclear survey system, Ann. Nucl. Energy 29 (2002) 2029-2040. https://doi.org/10.1016/S0306-4549(02)00031-2
- S.V. Guru, Z. He, J.C. Ferreria, D.K. Wehe, G.F. Knoll, A high energy gamma camera using a multiple hole collimator and PSPMT, Nucl. Instrum. Methods Phys. Res. A 353 (1994) 328-333. https://doi.org/10.1016/0168-9002(94)91668-3
- L. Mertz, N.O. Young, Fresnel transformation of images, Proc. Intl. Conf. Opt. Instrum. (1961) 305-310.
- E.E. Fenimore, T.M. Cannon, Coded aperture imaging with uniformly redundant arrays, Appl. Opt. 17 (3) (1978) 337-347. https://doi.org/10.1364/AO.17.000337
- W.R. Cook, M. Finger, T.A. Prince, E.C. Stone, Gamma-ray imaging with a rotating hexagonal uniformly redundant array, IEEE Trans. Nucl. Sci. NS-31 (1998) 771-775.
- S.R. Gottesman, E.E. Fenimore, New family of binary arrays for coded aperture imaging, Appl. Opt. 28 (20) (1989) 4344-4352. https://doi.org/10.1364/AO.28.004344
- P.T. Durrant, M. Dallimore, I.D. Jupp, D. Ramsden, The application of pinhole and coded aperture imaging in the nuclear environment, Nucl. Instrum. Methods Phys. Res. A 422 (1999) 667-671. https://doi.org/10.1016/S0168-9002(98)01014-6
- J. Braga, T. Villela, U.B. Jayanthi, F. D'Amico, J.A. Neri, A new mask-antimask coded-aperture telescope for hard X-ray astronomy, Exp. Astron. 2 (2) (1991) 101-113. https://doi.org/10.1007/BF00576323
- R. Accorsi, F. Gasparini, R.C. Lanza, Optimal coded aperture patterns for improved SNR in nuclear medicine imaging, Nucl. Instrum. Methods Phys. Res. A 474 (2001) 273-284. https://doi.org/10.1016/S0168-9002(01)01326-2
- M.J. Cieslak, K.A.A. Gamage, R. Glover, Coded-aperture imaging systems: past, present and future development e a review, Radiatt Meas. 92 (2016) 59-71. https://doi.org/10.1016/j.radmeas.2016.08.002
- K. Lange, R. Carson, EM reconstruction algorithms for emission and transmission tomography, J. Comput. Assist. Tomogr 8 (2) (1997) 306-316.
- M.J. Berger, J.H. Hubbell, S.M. Seltzer, J. Chang, J.S. Coursey, R. Sukumar, D.S. Zucker, K. Olsen, XCOM: Photon Cross Sections Database, NBSIR 87-3597. Available at: www.nist.gov/pml/xcom-photon-cross-sections-database.
- W.D. Ruhter, R. Gunnink, Application of cadmium-zinc-telluride detectors in 235U enrichment measurements, Nucl. Instrum. Methods Phys. Res. A 353 (1994) 716-718. https://doi.org/10.1016/0168-9002(94)91760-4
- T. Lee, W. Lee, Compact hybrid gamma camera with a coded aperture for investigation of nuclear materials, Nucl. Instrum. Methods Phys. Res. A 767 (2014) 5-13.
- J.P. Francois, On the calculation of the self-absorption in spherical radioactive sources, Nucl. Instrum. Methods Phys. Res. A 177 (1967) 153-156.
- G.F. Knoll, Radiation Detection and Measurement, fourth ed., Wiley, New York, 2010.
- R.Q. Richard, C.M. Hopper, Calculation of minimum critical mass of fissile nuclides, Nucl. Sci. Eng. 158 (2008) 203-209. https://doi.org/10.13182/NSE08-A2747
- M.S.E. Naschie, A. Hussein, On the eigenvalue of nuclear reaction and selfweight buckling, Chaos Solitons Fractals 11 (2000), 815-815. https://doi.org/10.1016/S0960-0779(99)00106-X
Cited by
- Gamma-ray modulation properties of tungsten coded apertures for a novel mixed-field imaging system vol.14, pp.2, 2018, https://doi.org/10.1088/1748-0221/14/02/p02007
- High performance γ-ray imager using dual anti-mask method for the investigation of high-energy nuclear materials vol.53, pp.7, 2018, https://doi.org/10.1016/j.net.2021.01.027
- Localizing hot spots in Poisson radiation data matrices: nonnegative tensor factorization and phase congruency vol.8, pp.1, 2018, https://doi.org/10.1186/s40537-021-00510-1