초록

This study presents the reliability assessment of a 100.5 m tall reinforced concrete chimney at a glass factory under wind loading by using vibration-based identified modal values. Ambient vibration measurements were recorded and modal values such as frequencies, shapes and damping ratios were identified by using Enhanced Frequency Domain Decomposition (EFDD) method. Afterwards, Finite Element Model (FEM) of the chimney was verified based on identified modal parameters. Reliability assessment of the chimney under wind loading was performed by obtaining the exceedance probability of demand to capacity distribution. Demand distribution of the chimney was developed under repetitive seeds of multivariate stochastic wind fields generated along the height of chimney. Capacity distribution of the chimney was developed by Monte Carlo simulation. Finally, it was found that reliability of the chimney is lower than code suggested limit values.

키워드

참고문헌

  1. ACI 307 (2008), Code Requirements for Reinforced Concrete Chimneys and Commentary, American Concrete Institute; Farmington Hills, MI, USA.
  2. Breuer, P., Chmieleweski, T., Gorski, P., Konoppka, E. and Tarczynski, L (2015), "Monitoring horizontal displacements in a vertical profile of a tall industrial chimney using GPS technology for detecting dynamic characteristics", Struct. Control Health Monit., 22, 1002-2023. https://doi.org/10.1002/stc.1730
  3. Brincker R., Zhang L. and Andersen P. (2001), "Modal identification of output-only systems using frequency domain decomposition", Smart Mater. Struct., 10, 441-445. https://doi.org/10.1088/0964-1726/10/3/303
  4. Brownjohn J.M.W. (2007), "Structural health monitoring of civil infrastructure", Philos. T. Roy. Soc., A365, 589-622.
  5. Brownjohn, J.M.W., Carden, E.P., Goddard, C.R. and Oudin, G. (2010), "Real-time performance monitoring of tuned mass damper system for a 183 m reinforced concrete chimney", J. Wind Eng. Ind. Aerod., 98(3), 169-179. https://doi.org/10.1016/j.jweia.2009.10.013
  6. Carden, E.P. and Fanning, P. (2004), "Vibration-based condition monitoring-A Review", Struct. Health Monit., 3(4), 355-377. https://doi.org/10.1177/1475921704047500
  7. CICIND Model Code for Concrete Chimneys and Commentary, (2001), International Committee for Industrial Chimneys; Ratingen, Germany.
  8. Deodatis, G. (1996), "Simulation of ergodic multivariate stochastic processes", J. Eng. Mech., 122(8), 778-787. https://doi.org/10.1061/(ASCE)0733-9399(1996)122:8(778)
  9. Deodatis, G. and Shinozuka, M. (1989), "Simulation of seismic ground motion using stochastic waves", J. Eng. Mech., 115(12), 2723-2737. https://doi.org/10.1061/(ASCE)0733-9399(1989)115:12(2723)
  10. Doebling, S.W., Farrar, C.R., Prime, M.B. and Shevitz, D.W. (1996), "Damage identification and health monitoring of structural and mechanical systems from changes in their vibration characteristics: A literature review", Research Report No: LA-13070-MS, Los Alamos National Laboratory, US.
  11. Ellingwood, B., Galambos, T.V., MacGregor, J.G. and Cornell, C.A. (1980), "Development of a probability based load criterion for American national standard A58", Research Report No: 577, National Bureau of Standard, US.
  12. Eurocode (2002), Basis of Structural Design. European Committee for Standardization; Brussels, Belgium.
  13. Eurocode 2 (2004), Design of Concrete Structures Part1-1. European Committee for Standardization; Brussels, Belgium.
  14. Gorski, P, (2015), "Investigation of dynamic characteristics of tall industrial chimney based on GPS measurements using random decrement method", Eng. Struct., 83, 30-49. https://doi.org/10.1016/j.engstruct.2014.11.006
  15. Gorski, P. (2017), "Dynamic characteristic of tall industrial chimney estimated from GPS measurement and frequency domain decomposition", Eng. Struct., 148, 277-292. https://doi.org/10.1016/j.engstruct.2017.06.066
  16. Holmes, J.D. (2001), "Wind loading of Structures", Spon Press, London, UK.
  17. Hong, H.P., Beadle, S. and Escobar, J.A. (2001), "Probabilistic assessment of wind-sensitive structures with uncertain parameters", J. Wind Eng. Ind. Aerod., 89, 893-910. https://doi.org/10.1016/S0167-6105(01)00076-9
  18. Kareem, A. (2008), "Numerical simulation of wind effects: A probabilistic perspective", J. Wind Eng. Ind. Aerod., 96, 1472-1497. https://doi.org/10.1016/j.jweia.2008.02.048
  19. Kareem, A. and Hsieh, J. (1986) "Reliability analysis of concrete chimneys under wind loading", J. Wind Eng. Ind. Aerod., 25(1), 93-112. https://doi.org/10.1016/0167-6105(86)90106-6
  20. Kareem, A. and Hsieh, J. (1988), "Statistical analysis of tubular R/C sections", J. Struct. Eng., 114(1), 900-916. https://doi.org/10.1061/(ASCE)0733-9445(1988)114:4(900)
  21. Li, Y. and Kareem, A. (1991), "Simulation of multi-variate nonstationary random processes by FFT", J. Eng. Mech., 117(5), 1037-1058. https://doi.org/10.1061/(ASCE)0733-9399(1991)117:5(1037)
  22. MacGregor, J.G., Mirza, S.A. and Ellingwood, B. (1983), "Statistical analysis of resistance of reinforced and prestressed concrete members", ACI Struct. J., 80(3), 167-176
  23. Mirza, S.A. and MacGregor, J.G. (1979), Variability of mechanical properties of reinforcing bars", J. Struct. Div. - ASCE, 105(4), 921-937
  24. Niemann, H.J. and Lupi, F. (2013), "International standardization of wind actions on chimneys", CICIND Report.
  25. Pallares, F.J., Ivorra, S. and Adam, J.M. (2009), "Monitoring chimneys with operational modal analysis", Proceedings of the International Operational Modal Analysis Conference, Portonovo, Italy
  26. Ruscheweyh, H. and Galemann, T. (1996), "Full-scale measurements of wind-induced oscillations of chimneys", J. Wind Eng. Ind. Aerod., 65, 55-62. https://doi.org/10.1016/S0167-6105(97)00022-6
  27. Sancibrian, R., Lombillo, I., Sarabia, E.G., Boffill, Y., Wong, H. and Villegas, Y. (2017), "Dynamic identification and condition assessment of an old masonry chimney by using modal testing", Proceedings of the International Conference on Structural Dynamics, Rome, Italy.
  28. Shinozuka, M. (1974), "Digital simulation of random processes in engineering mechanics with the aid of the FFT technique", University of Waterloo Press, Waterloo, Canada.
  29. Shinozuka, M. and Jan, C.M. (1972), "Digital simulation of random processes and its applications", J. Sound Vib., 25(1), 111-128. https://doi.org/10.1016/0022-460X(72)90600-1
  30. Shinozuka, M., Kamata, M. and Yun, C.B. (1989), "Simulation of Earthquake Ground Motion as Multi-Variate Stochastic Process", Princeton-Kajima Joint Research, Princeton, N.J, US
  31. Simiu, E. and Scanlan, R.H. (1996), "Wind Effects on Structures", John Wiley & Sons, N.Y.C, US.
  32. Sohn, H., Farrar, C.R., Hemez, F.M., Shunk, D.D., Stinemates, D.W., Nadler, B.R. and Czarnecki, J.J. (2004), "A Review of Structural Health Monitoring Literature", Research Report No: LA-13976-MS; Los Alamos National Laboratory Report, US.
  33. Tessari, R.K., Kroetz, H.M. and Beck, A.T. (2017), "Performancebased design of steel towers subject to wind actions", Eng. Struct., 143, 549-557. https://doi.org/10.1016/j.engstruct.2017.03.053
  34. Vickery, B.J. and Basu, R.I. (1983), "Across-wind vibrations of structures of circular cross section. Part II: Development of a mathematical model for full-scale application", J. Wind Eng. Ind. Aerod., 12(1), 75-97. https://doi.org/10.1016/0167-6105(83)90081-8
  35. Zhang, L.L, Lie, J. and Peng, Y. (2008), "Dynamic response and reliability analysis of tall buildings subject to wind loading", J. Wind Eng. Ind. Aerod., 96(1), 25-40. https://doi.org/10.1016/j.jweia.2007.03.001
  36. Zhang, L.L, Lie, J. and Peng, Y. (2008), "Dynamic response and reliability analysis of tall buildings subject to wind loading", J. Wind Eng. Ind. Aerod., 96(1), 25-40. https://doi.org/10.1016/j.jweia.2007.03.001