DOI QR코드

DOI QR Code

Reliability and Validity of a Force-Sensing Resistor for the Measurement of Static Hindlimb Weight Distribution in Beagle Dogs

  • Heo, Su-Young (College of Veterinary Medicine, Chonbuk National University) ;
  • Jeong, Heejun (College of Veterinary Medicine, Chungnam National University) ;
  • Jeong, Jaemin (College of Veterinary Medicine, Chungnam National University) ;
  • Jeong, Seong Mok (College of Veterinary Medicine, Chungnam National University) ;
  • Lee, HaeBeom (College of Veterinary Medicine, Chungnam National University)
  • Received : 2018.03.08
  • Accepted : 2018.07.30
  • Published : 2018.10.31

Abstract

The purpose of this study was to evaluate the reliability and validity of the Force-Sensing Resistor (FSR) for measurement of static hindlimb weight distribution in beagle dogs and to compare these results to a Digital Weighing Scale (DWS). Nine healthy beagle dogs were recruited for this study. Static weight distribution was evaluated four times at intervals of 5 days with each device and two observers to calculate the intra- and interobserver reliability. The intraclass correlation coefficient (ICC) values of the FSR for intraobserver reliability were moderate to good (0.74). The results for the DWS showed poor to moderate (0.56) ICC values for intraobserver reliability. The ICC values for interobserver reliability were 0.53 and 0.61 for FSR and DWS, respectively, indicating poor to moderate agreement. Our findings suggest that the Force-Sensing Resistor can be used to measure static weight distribution in veterinary medicine. However, caution should be taken when comparing measured values of static weight distribution obtained utilizing both the FSR and DWS due to their low positive correlation (R = 0.41, p < 0.01).

Keywords

References

  1. Besancon M, Conzemius M, Derrick T, Ritter M. Comparison of vertical forces in normal greyhounds between force platform and pressure walkway measurement systems. Vet Comp Orthop Traumatol. 2003; 16: 153. https://doi.org/10.1055/s-0038-1632766
  2. Bosscher G, Tomas A, Roe SC, Marcellin-Little DJ, Lascelles BD. Repeatability and accuracy testing of a weight distribution platform and comparison to a pressure sensitive walkway to assess static weight distribution. Vet Comp Orthop Traumatol. 2017; 30: 160-164. https://doi.org/10.3415/VCOT-16-09-0128
  3. Brenton-Rule A, Mattock J, Carroll M, Dalbeth N, Bassett S, Menz HB, Rome K. Reliability of the TekScan MatScan(R) system for the measurement of postural stability in older people with rheumatoid arthritis. J Foot Ankle Res. 2012; 5: 21. https://doi.org/10.1186/1757-1146-5-21
  4. Brookhart J, Parmeggiani P, Petersen W, Stone S. Postural stability in the dog. Am J Physiol. 1965; 208: 1047-1057.
  5. Colborne GR, Good L, Cozens LE, Kirk LS. Symmetry of hind limb mechanics in orthopedically normal trotting Labrador Retrievers. Am J Vet Res. 2011; 72: 336-344. https://doi.org/10.2460/ajvr.72.3.336
  6. DuLaney D, Purinton T, Dookwah H, Budsberg S. Effect of starting distance on vertical ground reaction forces in the normal dog. Vet Comp Orthop Traumatol. 2005; 18: 183-185. https://doi.org/10.1055/s-0038-1632943
  7. Evans R, Gordon W, Conzemius M. Effect of velocity on ground reaction forces in dogs with lameness attributable to tearing of the cranial cruciate ligament. Am J Vet Res. 2003; 64: 1479-1481. https://doi.org/10.2460/ajvr.2003.64.1479
  8. Goetschius J, Feger MA, Hertel J, Hart JM. Validating Center of Pressure Balance Measurements Using the MatScan(R) Pressure Mat. J Sport Rehabil. 2017: 1-14.
  9. Htwe O, MsPT LHJ, Esfehani AJ. Reliability, agreement, and validity of digital weighing scale with MatScan in limb load measurement. J Rehabil Res Dev. 2014; 51: 591. https://doi.org/10.1682/JRRD.2013.07.0166
  10. Hurkmans H, Bussmann J, Benda E, Verhaar J, Stam H. Techniques for measuring weight bearing during standing and walking. Clin Biomech. 2003; 18: 576-589. https://doi.org/10.1016/S0268-0033(03)00116-5
  11. Hyytiainen HK, Molsa SH, Junnila JT, Laitinen-Vapaavuori OM, Hielm-Bjorkman AK. Use of bathroom scales in measuring asymmetry of hindlimb static weight bearing in dogs with osteoarthritis. Vet Comp Orthop Traumatol. 2012; 25: 390-396. https://doi.org/10.3415/VCOT-11-09-0135
  12. Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016; 15: 155-163. https://doi.org/10.1016/j.jcm.2016.02.012
  13. Kumar SN, Omar B, Htwe O, Joseph LH, Krishnan J, Jafarzedah Esfehani A, Min LL. Reliability, agreement, and validity of digital weighing scale with MatScan in limb load measurement. J Rehabil Res Dev. 2014; 51: 591-598. https://doi.org/10.1682/JRRD.2013.07.0166
  14. Lascelles BD, Freire M, Roe SC, DePuy V, Smith E, Marcellin-Little DJ. Evaluation of functional outcome after BFX total hip replacement using a pressure sensitive walkway. Vet Surg. 2010; 39: 71-77. https://doi.org/10.1111/j.1532-950X.2009.00607.x
  15. Muir P. Physical examination of lame dogs. Comp Cont Educ Pract. 1997; 19: 1149-1160.
  16. Peham C, Licka T, Girtler D, Scheidl M. The influence of lameness on equine stride length consistency. Vet J. 2001; 162: 153-157. https://doi.org/10.1053/tvjl.2001.0593
  17. Phelps HA, Ramos V, Shires PK, Werre SR. The effect of measurement method on static weight distribution to all legs in dogs using the Quadruped Biofeedback System. Vet Comp Orthop Traumatol. 2007.
  18. Portney LG, Watkins M. Foundations of clinical research: applications to pratice, 3rd ed. Upper Saddle River, N.J.: Pearson/Prentice Hall. 2009.
  19. Seibert R, Marcellin-Little DJ, Roe SC, DePuy V, Lascelles BD. Comparison of body weight distribution, peak vertical force, and vertical impulse as measures of hip joint pain and efficacy of total hip replacement. Vet Surg. 2012; 41: 443-447. https://doi.org/10.1111/j.1532-950X.2012.00957.x
  20. Sharkey M. The challenges of assessing osteoarthritis and postoperative pain in dogs. AAPS J. 2013; 15: 598-607. https://doi.org/10.1208/s12248-013-9467-5
  21. Sprague S, Zink MC, Van Dyke JB. Introduction to canine rehabilitation. In: Canine Rehabilitation and Physical Therapy, 2nd ed. St. Louis, Missouri: Elsevier. 2014: 82-99.
  22. Zammit GV, Menz HB, Munteanu SE. Reliability of the TekScan MatScan(R) system for the measurement of plantar forces and pressures during barefoot level walking in healthy adults. J Foot Ankle Res. 2010; 3: 11. https://doi.org/10.1186/1757-1146-3-11