References
- Misch CE. Contemporary implant dentistry. 2nd ed. St. Louis: Mosby Inc; 1999. p. 549-93.
- Misch CE. Screw-retained versus cement-retained implant supported prostheses. Pract Periodontics Aesthet Dent 1995; 7:15-8.
- Hebel KS, Gajjar RC. Cement-retained versus screw-retained implant restorations: achieving optimal occlusion and esthetics in implant dentistry. J Prosthet Dent 1997;77:28-35. https://doi.org/10.1016/S0022-3913(97)70203-8
- Chee W, Felton DA, Johnson PF, Sullivan DY. Cemented versus screw-retained implant prostheses: which is better? Int J Oral Maxillofac Implants 1999;14:137-41.
- Ekfeldt A, Carlsson GE, Börjesson G. Clinical evaluation of single-tooth restorations supported by osseointegrated implants: a retrospective study. Int J Oral Maxillofac Implants 1994;9:179-83.
- Breeding LC, Dixon DL, Bogacki MT, Tietge JD. Use of luting agents with an implant system: Part I. J Prosthet Dent 1992;68:737-41. https://doi.org/10.1016/0022-3913(92)90194-F
- Valbao FP Jr, Perez EG, Breda M. Alternative method for retention and removal of cement-retained implant prostheses. J Prosthet Dent 2001;86:181-3. https://doi.org/10.1067/mpr.2001.115687
- Clausen GF. The lingual locking screw for implant-retained restorations--aesthetics and retrievability. Aust Prosthodont J 1995;9:17-20.
- Doerr J. Simplified technique for retrieving cemented implant restorations. J Prosthet Dent 2002;88:352-3. https://doi.org/10.1067/mpr.2002.128149
- Daher T, Morgano SM. The use of digital photographs to locate implant abutment screws for implant-supported cement-retained restorations. J Prosthet Dent 2008;100:238-9. https://doi.org/10.1016/S0022-3913(08)60187-0
- Wadhwani C, Chung KH. Simple device for locating the abut- ment screw position of a cement-retained implant restoration. J Prosthet Dent 2013;109:272-4. https://doi.org/10.1016/S0022-3913(13)60058-X
- Prestipino V, Ingber A, Kravitz J, Whitehead GM. A practical approach for retrieving cement-retained, implant-supported restorations. Quintessence Dent Technol 2001;24:182-7.
- Schweitzer DM, Berg RW, Mancia GO. A technique for retrieval of cement-retained implant-supported prostheses. J Prosthet Dent 2011;106:134-8. https://doi.org/10.1016/S0022-3913(11)60110-8
- Elshiyab SH, Nawafleh N, Öchsner A, George R. Fracture resistance of implant-supported monolithic crowns cemented to zirconia hybrid-abutments: zirconia-based crowns vs. lithium disilicate crowns. J Adv Prosthodont 2018;10:65-72. https://doi.org/10.4047/jap.2018.10.1.65
- Rödiger M, Rinke S, Ehret-Kleinau F, Pohlmeyer F, Lange K, Bürgers R, Gersdorff N. Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation. J Adv Prosthodont 2014;6:233-40. https://doi.org/10.4047/jap.2014.6.3.233
- Mehl C, Harder S, Shahriari A, Steiner M, Kern M. Influence of abutment height and thermocycling on retrievability of cemented implant-supported crowns. Int J Oral Maxillofac Implants 2012;27:1106-15.
- Mehl C, Harder S, Schwarz D, Steiner M, Vollrath O, Kern M. In vitro influence of ultrasonic stress, removal force preload and thermocycling on the retrievability of implant-retained crowns. Clin Oral Implants Res 2012;23:930-7. https://doi.org/10.1111/j.1600-0501.2011.02236.x
- Pintinha M, Camarini ET, Sábio S, Pereira JR. Effect of mechanical loading on the removal torque of different types of tapered connection abutments for dental implants. J Prosthet Dent 2013;110:383-8. https://doi.org/10.1016/j.prosdent.2013.06.007
- Mehl C, Harder S, Steiner M, Vollrath O, Kern M. Influence of cement film thickness on the retention of implant-retained crowns. J Prosthodont 2013;22:618-25. https://doi.org/10.1111/jopr.12058
- Abbo B, Razzoog ME, Vivas J, Sierraalta M. Resistance to dis- lodgement of zirconia copings cemented onto titanium abut- ments of different heights. J Prosthet Dent 2008;99:25-9. https://doi.org/10.1016/S0022-3913(08)60005-0
- Safari S, Hosseini Ghavam F, Amini P, Yaghmaei K. Effects of abutment diameter, luting agent type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments. J Adv Prosthodont 2018;10:1-7. https://doi.org/10.4047/jap.2018.10.1.1
- Covey DA, Kent DK, St Germain HA Jr, Koka S. Effects of abutment size and luting cement type on the uniaxial retention force of implant-supported crowns. J Prosthet Dent 2000;83:344-8. https://doi.org/10.1016/S0022-3913(00)70138-7
- Bresciano M, Schierano G, Manzella C, Screti A, Bignardi C, Preti G. Retention of luting agents on implant abutments of different height and taper. Clin Oral Implants Res 2005;16: 594-8. https://doi.org/10.1111/j.1600-0501.2005.01159.x
- Mehl C, Harder S, Wolfart M, Kern M, Wolfart S. Retrievability of implant-retained crowns following cementation. Clin Oral Implants Res 2008;19:1304-11. https://doi.org/10.1111/j.1600-0501.2008.01587.x
- Heinemann F, Mundt T, Biffar R. Retrospective evaluation of temporary cemented, tooth and implant supported fixed partial dentures. J Craniomaxillofac Surg 2006;34:86-90.
- Lim HP, Yoo JM, Park SW, Yang HS. Fracture load of implant-supported zirconia all-ceramic crowns luted with various cements. Int J Prosthodont 2010;23:361-3.
- Arrais CA, Giannini M, Rueggeberg FA, Pashley DH. Microtensile bond strength of dual-polymerizing cementing systems to dentin using different polymerizing modes. J Prosthet Dent 2007;97:99-106. https://doi.org/10.1016/j.prosdent.2006.12.007
- Lührs AK, De Munck J, Geurtsen W, Van Meerbeek B. Composite cements benefit from light-curing. Dent Mater 2014;30:292-301. https://doi.org/10.1016/j.dental.2013.11.012
- Youm SH, Jung KH, Son SA, Kwon YH, Park JK. Effect of dentin pretreatment and curing mode on the microtensile bond strength of self-adhesive resin cements. J Adv Prosthodont 2015;7:317-22. https://doi.org/10.4047/jap.2015.7.4.317
- Pan YH, Lin CK. The effect of luting agents on the retention of dental implant-supported crowns. Chang Gung Med J 2005;28:403-10.
- Harder S, Dimaczek B, Açil Y, Terheyden H, Freitag-Wolf S, Kern M. Molecular leakage at implant-abutment connection--in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration. Clin Oral Investig 2010;14:427-32. https://doi.org/10.1007/s00784-009-0317-x
- Chaar MS, Att W, Strub JR. Prosthetic outcome of cementretained implant-supported fixed dental restorations: a systematic review. J Oral Rehabil 2011;38:697-711. https://doi.org/10.1111/j.1365-2842.2011.02209.x
Cited by
- In Vitro Simulation of Dental Implant Bridges Removal: Influence of Luting Agent and Abutments Geometry on Retrievability vol.13, pp.12, 2018, https://doi.org/10.3390/ma13122797
- Analysis of the fit quality of the metal frames on implants depending on the abutment taper vol.100, pp.6, 2021, https://doi.org/10.17116/stomat202110006156
- Effect of Abutment Geometry and Luting Agents on the Vertical Marginal Discrepancy of Cast Copings on Implant Abutments: An In Vitro Study vol.2021, pp.None, 2021, https://doi.org/10.1155/2021/9950972