과제정보
연구 과제 주관 기관 : Daejin University
참고문헌
- Macovski A. Medical imaging systems. Englewood Cliffs: Prentice Hall; 1983.
- Jensen JA, Svendsen NB. Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers. IEEE Trans Ultrason Ferroelectr Freq Control. 1992;39(2):262-7. https://doi.org/10.1109/58.139123
- Holfort IK, Gran F, Jensen JA. Broadband minimum variance beamforming for ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2009;56(2):314-25. https://doi.org/10.1109/TUFFC.2009.1040
- Kim K, Park S, Kim J, Park SB, Bae M. A fast minimum variance beamforming method using principal component analysis. IEEE Trans Ultrason Ferroelectr Freq Control. 2014;61(6):930-45. https://doi.org/10.1109/TUFFC.2014.2989
- Seo CH, Yen JT. Sidelobe suppression in ultrasound imaging using dual apodization with cross-correlation. IEEE Trans Ultrason Ferroelectr Freq Control. 2008;55(10):2198-210. https://doi.org/10.1109/TUFFC.919
- Wagner RF, Smith SW, Sandrik JM, Lopez H. Statistics of speckle in ultrasound B-scans. IEEE Trans Sonics Ultrason. 1983;30(3):156-63. https://doi.org/10.1109/T-SU.1983.31404
- Keitman-Curdes O, Brendel B, Marg C, Ermert H. Optimization of apodizations based on the sidelobe pressure energy in simulated ultrasound fields. In: Proceedings of IEEE Ultrasonics Symposium Conference; 2003. p. 1677-80.
- Vignon F, Burcher MR. Capon beamforming in medical ultrasound imaging with focused beams. IEEE Trans Ultrason Ferroelectr Freq Control. 2008;55(3):619-28. https://doi.org/10.1109/TUFFC.2008.686
- Asl BM, Mahloojifar A. Minimum variance beamforming combined with adaptive coherence weighting applied to ultrasound medical imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2009;56(9):1923-31. https://doi.org/10.1109/TUFFC.2009.1268
- Asl BM, Mahloojifar A. Eigenspace-based minimum variance beamforming applied to medical ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2010;57(11):2381-90. https://doi.org/10.1109/TUFFC.2010.1706
- Li PC, Li ML. Adaptive imaging using the generalized coherence factor. IEEE Trans Ultrason Ferroelectr Freq Control. 2003;50(2):128-41. https://doi.org/10.1109/TUFFC.2003.1182117
- Lediju MA, Trahey GE, Byram BC, Dahl JJ. Short-lag spatial coherence of backscattered echoes: imaging characteristics. IEEE Trans Ultrason Ferroelectr Freq Control. 2011;58(7):1377-88. https://doi.org/10.1109/TUFFC.2011.1957
- Jeong MK. A Fourier transform-based sidelobe suppression method in ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2000;47(3):759-63. https://doi.org/10.1109/58.842066
- Jeong MK, Kwon SJ. Estimation of side lobes in ultrasound imaging systems. Biomed Eng Lett. 2015;5(3):229-39. https://doi.org/10.1007/s13534-015-0194-y
- Jeong MK, Kwon SJ. A novel side lobe estimation method in medical ultrasound imaging systems. In: Proceedings of IEEE Ultrasonics Symposium Conference; 2015.
- Kwon SJ, Jeong MK. Estimation and suppression of side lobes in medical ultrasound imaging systems. Biomed Eng Lett. 2017;7(1):31-43. https://doi.org/10.1007/s13534-016-0002-3
- Synnevag JF, Austeng A, Holm S. Minimum variance adaptive beamforming applied to medical ultrasound imaging. In: Proceedings of IEEE Ultrasonics Symposium Conference; 2005. p. 1199-202.
- Synnevag JF, Austeng A, Holm S. Adaptive beamforming applied to medical ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2007;54(8):1606-13. https://doi.org/10.1109/TUFFC.2007.431
피인용 문헌
- Optically Transparent Focused Transducers for Combined Photoacoustic and Ultrasound Microscopy vol.40, pp.5, 2018, https://doi.org/10.1007/s40846-020-00536-5
- A new method for assessing the performance of signal processing filters in suppressing the side lobe level vol.40, pp.2, 2018, https://doi.org/10.14366/usg.20032