DOI QR코드

DOI QR Code

Electromyography-signal-based muscle fatigue assessment for knee rehabilitation monitoring systems

  • Kim, Hyeonseok (Department of Information and Communications Engineering, Tokyo Institute of Technology) ;
  • Lee, Jongho (Department of Clinical Engineering, Faculty of Health Sciences, Komatsu University) ;
  • Kim, Jaehyo (Department of Mechanical and Control Engineering, Handong Global University)
  • Received : 2017.12.14
  • Accepted : 2018.06.27
  • Published : 2018.11.30

Abstract

This study suggested a new EMG-signal-based evaluation method for knee rehabilitation that provides not only fragmentary information like muscle power but also in-depth information like muscle fatigue in the field of rehabilitation which it has not been applied to. In our experiment, nine healthy subjects performed straight leg raise exercises which are widely performed for knee rehabilitation. During the exercises, we recorded the joint angle of the leg and EMG signals from four prime movers of the leg: rectus femoris (RFM), vastus lateralis, vastus medialis, and biceps femoris (BFLH). We extracted two parameters to estimate muscle fatigue from the EMG signals, the zero-crossing rate (ZCR) and amplitude of muscle tension (AMT) that can quantitatively assess muscle fatigue from EMG signals. We found a decrease in the ZCR for the RFM and the BFLH in the muscle fatigue condition for most of the subjects. Also, we found increases in the AMT for the RFM and the BFLH. Based on the results, we quantitatively confirmed that in the state of muscle fatigue, the ZCR shows a decreasing trend whereas the AMT shows an increasing trend. Our results show that both the ZCR and AMT are useful parameters for characterizing the EMG signals in the muscle fatigue condition. In addition, our proposed methods are expected to be useful for developing a navigation system for knee rehabilitation exercises by evaluating the two parameters in two-dimensional parameter space.

Keywords

References

  1. Holliday RC, Antoun M, Playford ED. A survey of goal-setting methods used in rehabilitation. Neurorehabilit Neural Repair. 2005;19(3):227-31. https://doi.org/10.1177/1545968305279206
  2. White G, Cordato D, O'Rourke F, Mendis R, Ghia D, Chan D. Validation of the Stroke Rehabilitation Motivation Scale: a pilot study. Asian J Gerontol Geriatr. 2012;7(2):80-7.
  3. Chen K-H, Chen P-C, Liu K-C, Chan C-T. Wearable sensor-based rehabilitation exercise assessment for knee osteoarthritis. Sensors-Basel. 2015;15(2):4193-211. https://doi.org/10.3390/s150204193
  4. Chen K-H, Tseng W-C, Liu K-C, Chan C-T. Using gyroscopes and accelerometers as a practical rehabilitation monitor system after total knee arthroplasty. 2015 International microwave workshop series on RF and wireless technologies for biomedical and healthcare applications (IMWS-BIO), 2015 IEEE MTT-S; 2015. p. 58-9.
  5. Taylor PE, Almeida GJ, Kanade T, Hodgins JK. Classifying human motion quality for knee osteoarthritis using accelerometers. In: 2010 Annual international conference of the IEEE engineering in medicine and biology; 2010. p. 339-43.
  6. Masdar A, Ibrahim B, Hanafi D, Jamil MMA, Rahman K. Knee joint angle measurement system using gyroscope and flex-sensors for rehabilitation. In: Biomedical engineering international conference (BMEiCON), 2013 6th.; 2013. p. 1-4.
  7. Milenkovic M, Jovanov E, Chapman J, Raskovic D, Price J. An accelerometer-based physical rehabilitation system. In: 2002 Proceedings of the thirty-fourth southeastern symposium on system theory; 2002. p. 57-60.
  8. Herzog W, Sokolosky J, Zhang Y, Guimaraes A. EMG-force relation in dynamically contracting cat plantaris muscle. J Electromyogr Kinesiol. 1998;8(3):147-55. https://doi.org/10.1016/S1050-6411(97)00015-1
  9. Liu MM, Herzog W, Savelberg HH. Dynamic muscle force predictions from EMG: an artificial neural network approach. J Electromyogr Kinesiol. 1999;9(6):391-400. https://doi.org/10.1016/S1050-6411(99)00014-0
  10. Liu P, Martel F, Rancourt D, Clancy EA, Brown DR. Fingertip force estimation from forearm muscle electrical activity. 2014 IEEE international conference on acoustics, speech and signal processing (ICASSP); 2014. p. 2069-73.
  11. Weir JP, Wagner LL, Housh TJ. Linearity and reliability of the IEMG v torque relationship for the forearm flexors and leg extensors. Am J Phys Med Rehabil. 1992;71(5):283-7. https://doi.org/10.1097/00002060-199210000-00006
  12. Lykholt LE, Ganeswarathas S, Thota AK, Harreby KR, Jung R. Information on ankle angle from intramuscular EMG Signals during development of muscle fatigue in an open-loop functional electrical stimulation system in rats. In: Winnie J, Ole KA, Metin A, editors. Replace, repair, restore, relieve-bridging clinical and engineering solutions in neurorehabilitation. Berlin: Springer; 2014. p. 529-36.
  13. Cifrek M, Medved V, Tonkovic S, Ostojic S. Surface EMG based muscle fatigue evaluation in biomechanics. Clin Biomech (Bristol, Avon). 2009;24(4):327-40. https://doi.org/10.1016/j.clinbiomech.2009.01.010
  14. Allen DG, Lamb GD, Westerblad H. Skeletal muscle fatigue: cellular mechanisms. Physiol Rev. 2008;88(1):287-332. https://doi.org/10.1152/physrev.00015.2007
  15. Amann M, Dempsey JA. Locomotor muscle fatigue modifies central motor drive in healthy humans and imposes a limitation to exercise performance. J Physiol. 2008;586(1):161-73. https://doi.org/10.1113/jphysiol.2007.141838
  16. Harput G, Kilinc HE, Ozer H, Baltaci G, Mattacola CG. Quadriceps and hamstring strength recovery during early neuromuscular rehabilitation after ACL hamstring-tendon autograft reconstruction. J Sport Rehabil. 2015;24(4):398-404. https://doi.org/10.1123/jsr.2014-0224
  17. Hawley JA, Myburgh K, Noakes TD, Dennis S. Training techniques to improve fatigue resistance and enhance endurance performance. J Sports Sci. 1997;15(3):325-33. https://doi.org/10.1080/026404197367335
  18. Hicks Audrey L, Kent-Braun Jane, Ditor David S. Sex differences in human skeletal muscle fatigue. Exerc Sport Sci Rev. 2001;9(3):109-12.
  19. Lindstrom B, Karlsson S, Gerdle B. Knee extensor performance of dominant and non-dominant limb throughout repeated isokinetic contractions, with special reference to peak torque and mean frequency of the EMG. Clin Physiol Funct Imaging. 1995;15(3):275-86.
  20. Vollestad NK. Measurement of human muscle fatigue. J Neurosci Methods. 1997;74(2):219-27. https://doi.org/10.1016/S0165-0270(97)02251-6
  21. Koike Y, Kawato M. Estimation of arm posture in 3D-space from surface EMG signals using a neural network model. IEICE Trans Inf Syst. 1994;77(4):368-75.
  22. Christanell F, Hoser C, Huber R, Fink C, Luomajoki H. The influence of electromyographic biofeedback therapy on knee extension following anterior cruciate ligament reconstruction: a randomized controlled trial. BMC Sports Sci Med Rehabil. 2012;4(1):1. https://doi.org/10.1186/1758-2555-4-1
  23. Draper V. Electromyographic biofeedback and recovery of quadriceps femoris muscle function following anterior cruciate ligament reconstruction. Phys Ther. 1990;70(1):11-7. https://doi.org/10.1093/ptj/70.1.11
  24. Giggins OM, Persson UM, Caulfield B. Biofeedback in rehabilitation. J Neuroeng Rehabil. 2013;10(1):1.
  25. Holtermann A, Mork P, Andersen L, Olsen HB, Sogaard K. The use of EMG biofeedback for learning of selective activation of intra-muscular parts within the serratus anterior muscle: a novel approach for rehabilitation of scapular muscle imbalance. J Electromyogr Kinesiol. 2010;20(2):359-65. https://doi.org/10.1016/j.jelekin.2009.02.009
  26. Middaugh S, Thomas KJ, Smith AR, McFall TL, Klingmueller J. EMG biofeedback and exercise for treatment of cervical and shoulder pain in individuals with a spinal cord injury: a pilot study. Top Spinal Cord Inj Rehabil. 2013;19(4):311. https://doi.org/10.1310/sci1904-311
  27. Sturma A, Gobel P, Herceg M, Gee N, Roche A, Fialka-Moser V, et al. Advanced rehabilitation for amputees after selective nerve transfers: EMG-guided training and testing. In: Winnie J, Ole KA, Metin A, editors. Replace, repair, restore, relieve-bridging clinical and engineering solutions in neurorehabilitation. Berlin: Springer; 2014. p. 169-77.
  28. Holtermann A, Gronlund C, Karlsson JS, Roeleveld K. Motor unit synchronization during fatigue: described with a novel sEMG method based on large motor unit samples. J Electromyogr Kinesiol. 2009;19(2):232-41. https://doi.org/10.1016/j.jelekin.2007.08.008
  29. Hunter SK, Enoka RM. Changes in muscle activation can prolong the endurance time of a submaximal isometric contraction in humans. J Appl Physiol. 2003;94(1):108-18. https://doi.org/10.1152/japplphysiol.00635.2002
  30. Lee S, Koo K, Lee Y, Lee J, Kim J. Spatiotemporal analysis of EMG signals for muscle rehabilitation monitoring system. In: 2013 IEEE 2nd global conference on consumer electronics (GCCE); 2013. p. 1-2.
  31. Enoka RM, Stuart DG. Neurobiology of muscle fatigue. J Appl Physiol. 1992;72(5):1631-48.
  32. Shin D, Kim J, Koike Y. A myokinetic arm model for estimating joint torque and stiffness from EMG signals during maintained posture. J Neurophysiol. 2009;101:387-401. https://doi.org/10.1152/jn.00584.2007
  33. Flores E, Tobon G, Cavallaro E, Cavallaro FI, Perry JC, Keller T. Improving patient motivation in game development for motor deficit rehabilitation. In: Proceedings of the 2008 international conference on advances in computer entertainment technology; 2008. p. 381-4.

Cited by

  1. Implementation of a Portable Electromyographic Prototype for the Detection of Muscle Fatigue vol.8, pp.6, 2018, https://doi.org/10.3390/electronics8060619
  2. Shape memory alloy actuation of non-bonded piezo sensor configuration for bone diagnosis and impedance based analysis vol.9, pp.4, 2018, https://doi.org/10.1007/s13534-019-00128-6
  3. Effect of Mechanical Stimulation Applied to the Lower-Limb Musculature on Stability and Function of Stair Climbing vol.10, pp.3, 2020, https://doi.org/10.3390/app10030799
  4. Potential Instability and Malfunction of Knee Joints with Vastus Medialis Impairment after Total Knee Arthroplasty vol.11, pp.6, 2021, https://doi.org/10.3390/app11062764
  5. Retentive capacity of power output and linear versus non-linear mapping of power loss in the isotonic muscular endurance test vol.11, pp.1, 2021, https://doi.org/10.1038/s41598-021-02116-2