DOI QR코드

DOI QR Code

Optical Sensitivity of TL Glow Peaks Separated Using Computerized Glow Curve Deconvolution for RTL Quartz

  • Kim, Myung-Jin (Archaeological Science Institute, RADPION Inc.) ;
  • Kim, Ki-Bum (Institute of Liberal Education, Kangwon National University) ;
  • Hong, Duk-Geun (Department of Physics, Kangwon National University)
  • Received : 2018.07.25
  • Accepted : 2018.09.27
  • Published : 2018.09.30

Abstract

Background: The retrospective dosimetry using RTL quartz can be improved by information for an optical sensitivity of sample connected with the equivalent dose determination. Materials and Methods: The quartz sample from a volcanic rock of Japan was used. After correcting the thermal quenching effect, RTL peaks of quartz were separated by the CGCD method cooperated with the general order kinetics. The number of overlapped glow peaks were ascertained by the $T_m-T_{stop}$ method. The optical sensitivity was examined by comparing the change of intensity on RTL glow peaks measured after exposure to light from a solar simulator with various illumination times. Results and Discussion: Seven glow peaks appeared to be overlapped on the RTL glow curve. The general order kinetics model was appropriate to separate glow peaks. After exposure to light from a solar simulator from a few minutes to 416 hr, the signals for peaks P4 and P5 decayed following the form of $f(t)=a_1e^{-{\lambda}1t}$, while the signals for peaks P6 and P7 decayed by the form of $f(t) = a_1e^{-{\lambda}1t}+a_2e^{-{\lambda}2t}+a_3e^{-{\lambda}3t}$. Conclusion: For dosimetric peaks, the times taken to reduce the RTL signal to half of its initial value were 70 sec for the peak P4, 54 s for the peak P5, 9,840 sec for the peak P6 and 26,580 sec for the peak P7, respectively. We conclude that the optical sensitivity of peaks P4, and P5 gives much higher than that of peaks P6 and P7.

Keywords

References

  1. Franklin AD, Prescott JR, Robertson GB. Comparison of blue and red TL from quartz. Radiat. Meas. 2000;32(5-6):633-639. https://doi.org/10.1016/S1350-4487(00)00050-0
  2. Fattahi M, Stokes S. Extending the time range of luminescence dating using red TL (RTL) from volcanic quartz. Radiat. Meas. 2005;32(5-6):479-485. https://doi.org/10.1016/S1350-4487(00)00105-0
  3. Scholefield RB, Prescott JR. The red thermoluminescence of quartz: 3-D spectral measurement. Radiat. Meas. 1999;30(1):83-95. https://doi.org/10.1016/S1350-4487(98)00094-8
  4. Lai Z, Murray A. Red TL of quartz extracted from Chinese loess: bleachability and saturation dose. Radiat. Meas. 2006;41(7-8): 836-840. https://doi.org/10.1016/j.radmeas.2006.04.017
  5. Pagonis V, Tatsis E, Kitis G. Search for common characteristics in the glow curves of quartz of various origins. Radiat. Prot. Dosim. 2002;100(1-4):373-376. https://doi.org/10.1093/oxfordjournals.rpd.a005892
  6. Yazici AN, Topaksu M. The analysis of thermoluminescence glow peaks of unannealed synthetic quartz. J. Phys. D: Appl. Phys. 2003; 36(6):620-627. https://doi.org/10.1088/0022-3727/36/6/303
  7. Horowitz YS, Yossian, D. Computerised glow curve deconvolution: application to thermoluminescence dosimetry. Radiat. Prot. Dosim. 1995;60:1-111.
  8. Hashimoto T, Sugai N, Sakaue H, Yasuda K, Shirai N. Thermoluminescence (TL) spectra from quartz grains using on-line TLspectrometric system. Geochem. J. 1997;31(4):189-201. https://doi.org/10.2343/geochemj.31.189
  9. Kitis G, Pagonis V, Drupieski C. Cooling rate effects on the thermoluminescence glow curves of Arkansas quartz. Phys. Status Solidi A. 2003;198(2):312-321. https://doi.org/10.1002/pssa.200306601
  10. Song KW, Kim KB, Hong DG. Determination of trap parameters for thermoluminescence glow peaks of red thermoluminescence of quartz from Japan. Radiat. Eff. Defects Solids. 2010;165(4): 305-312. https://doi.org/10.1080/10420151003631910
  11. McKeever SWS. On the analysis of complex thermoluminescence glow-curves: resolution into individual peaks. Phys. Status Solidi A. 1980;62(1):331-340. https://doi.org/10.1002/pssa.2210620139
  12. Kitis G, Gomez-Ros JM, Tuyn JWN. Thermoluminescence glowcurve deconvolution functions for first, second and general orders of kinetics. J. Phys. D: Appl. Phys. 1998;31(19):2636-2641. https://doi.org/10.1088/0022-3727/31/19/037
  13. Balian HG, Eddy NW. Figure-of merit (FOM) an improved criterion over the normalized Chi-squared test of assessing goodness-of-fit of gamma-ray spectra peaks. Nucl. Instrum. Methods. 1997;145(2):389-395.