Radiation safety: a focus on lead aprons and thyroid shields in interventional pain management

  • Cheon, Bo Kyung (Department of Anesthesiology and Pain Medicine, Konkuk University School of Medicine) ;
  • Kim, Cho Long (Department of Anesthesiology and Pain Medicine, Konkuk University School of Medicine) ;
  • Kim, Ka Ram (Department of Anesthesiology and Pain Medicine, Konkuk University School of Medicine) ;
  • Kang, Min Hye (Department of Anesthesiology and Pain Medicine, Konkuk University School of Medicine) ;
  • Lim, Jeong Ae (Department of Anesthesiology and Pain Medicine, Konkuk University School of Medicine) ;
  • Woo, Nam Sik (Department of Anesthesiology and Pain Medicine, Konkuk University School of Medicine) ;
  • Rhee, Ka Young (Department of Anesthesiology and Pain Medicine, Konkuk University School of Medicine) ;
  • Kim, Hae Kyoung (Department of Anesthesiology and Pain Medicine, Konkuk University School of Medicine) ;
  • Kim, Jae Hun (Department of Anesthesiology and Pain Medicine, Konkuk University School of Medicine)
  • Received : 2018.02.20
  • Accepted : 2018.06.18
  • Published : 2018.10.01

Abstract

C-arm fluoroscopy is useful equipment in interventional pain management because it helps to guide correct needle targeting for the accurate injection and drug delivery. However, due to increased use of C-arm fluoroscopy in various pain procedures, the risk of radiation exposure is a significant concern for pain physicians. The harmful biological effects of ionizing radiation on the human body are well known. It is therefore necessary to strive to reduce radiation exposure. Lead aprons with thyroid shields are the most fundamental radiation protective devices for interventional procedures, and are very effective. However, the operator's radiation safety cannot be guaranteed because pain physicians seem to lack sufficient interest, knowledge, and awareness about radiation safety. Also, inappropriate care and use of radiation protective devices may result in a higher risk of radiation exposure. The purpose of this article was to review the literature on radiation safety with a focus on lead aprons and thyroid shields and present recommendations related to those devices during C-arm fluoroscopic-guided interventions by pain physicians.

Keywords

References

  1. Kim S, Shin JH, Lee JW, Kang HS, Lee GY, Ahn JM. Factors affecting radiation exposure during lumbar epidural steroid injection: a prospective study in 759 patients. Korean J Radiol 2016; 17: 405-12. https://doi.org/10.3348/kjr.2016.17.3.405
  2. Linet MS, Kim KP, Miller DL, Kleinerman RA, Simon SL, Berrington de Gonzalez A. Historical review of occupational exposures and cancer risks in medical radiation workers. Radiat Res 2010; 174: 793-808. https://doi.org/10.1667/RR2014.1
  3. Kim TW, Jung JH, Jeon HJ, Yoon KB, Yoon DM. Radiation exposure to physicians during interventional pain procedures. Korean J Pain 2010; 23: 24-7. https://doi.org/10.3344/kjp.2010.23.1.24
  4. Tsapaki V, Kottou S, Vano E, Parviainen T, Padovani R, Dowling A, et al. Correlation of patient and staff doses in interventional cardiology. Radiat Prot Dosimetry 2005; 117: 26-9. https://doi.org/10.1093/rpd/nci705
  5. Kim TH, Hong SW, Woo NS, Kim HK, Kim JH. The radiation safety education and the pain physicians' efforts to reduce radiation exposure. Korean J Pain 2017; 30: 104-15. https://doi.org/10.3344/kjp.2017.30.2.104
  6. Park PE, Park JM, Kang JE, Cho JH, Cho SJ, Kim JH, et al. Radiation safety and education in the applicants of the final test for the expert of pain medicine. Korean J Pain 2012; 25: 16-21. https://doi.org/10.3344/kjp.2012.25.1.16
  7. Fishman SM, Smith H, Meleger A, Seibert JA. Radiation safety in pain medicine. Reg Anesth Pain Med 2002; 27: 296-305. https://doi.org/10.1097/00115550-200205000-00012
  8. Kim C, Vasaiwala S, Haque F, Pratap K, Vidovich MI. Radiation safety among cardiology fellows. Am J Cardiol 2010; 106: 125-8. https://doi.org/10.1016/j.amjcard.2010.02.026
  9. Dagal A. Radiation safety for anesthesiologists. Curr Opin Anaesthesiol 2011; 24: 445-50. https://doi.org/10.1097/ACO.0b013e328347f984
  10. Manchikanti L, Cash KA, Moss TL, Pampati V. Radiation exposure to the physician in interventional pain management. Pain Physician 2002; 5: 385-93.
  11. Le Heron J, Padovani R, Smith I, Czarwinski R. Radiation protection of medical staff. Eur J Radiol 2010; 76: 20-3. https://doi.org/10.1016/j.ejrad.2010.06.034
  12. Blakely EA. Biological effects of cosmic radiation: deterministic and stochastic. Health Phys 2000; 79: 495-506. https://doi.org/10.1097/00004032-200011000-00006
  13. Shortt CP, Fanning NF, Malone L, Thornton J, Brennan P, Lee MJ. Thyroid dose during neurointerventional procedures: does lead shielding reduce the dose? Cardiovasc Intervent Radiol 2007; 30: 922-7. https://doi.org/10.1007/s00270-007-9093-7
  14. Sont WN, Zielinski JM, Ashmore JP, Jiang H, Krewski D, Fair ME, et al. First analysis of cancer incidence and occupational radiation exposure based on the National Dose Registry of Canada. Am J Epidemiol 2001; 153: 309-18. https://doi.org/10.1093/aje/153.4.309
  15. Manchikanti L, Cash KA, Moss TL, Pampati V. Effectiveness of protective measures in reducing risk of radiation exposure in interventional pain management: a prospective evaluation. Pain Physician 2003; 6: 301-5.
  16. Broadman LM, Navalgund YA, Hawkinberry DW 2nd. Radiation risk management during fluoroscopy for interventional pain medicine physicians. Curr Pain Headache Rep 2004; 8: 49-55. https://doi.org/10.1007/s11916-004-0040-x
  17. Zhou Y, Singh N, Abdi S, Wu J, Crawford J, Furgang FA. Fluoroscopy radiation safety for spine interventional pain procedures in university teaching hospitals. Pain Physician 2005; 8: 49-53.
  18. Roguin A, Goldstein J, Bar O, Goldstein JA. Brain and neck tumors among physicians performing interventional procedures. Am J Cardiol 2013; 111: 1368-72. https://doi.org/10.1016/j.amjcard.2012.12.060
  19. Leuraud K, Richardson DB, Cardis E, Daniels RD, Gillies M, O'Hagan JA, et al. Ionising radiation and risk of death from leukaemia and lymphoma in radiation-monitored workers (INWORKS): an international cohort study. Lancet Haematol 2015; 2: e276-81. https://doi.org/10.1016/S2352-3026(15)00094-0
  20. Andreassi MG, Piccaluga E, Gargani L, Sabatino L, Borghini A, Faita F, et al. Subclinical carotid atherosclerosis and early vascular aging from long-term low-dose ionizing radiation exposure: a genetic, telomere, and vascular ultrasound study in cardiac catheterization laboratory staff. JACC Cardiovasc Interv 2015; 8: 616-27.
  21. Biswas D, Bible JE, Bohan M, Simpson AK, Whang PG, Grauer JN. Radiation exposure from musculoskeletal computerized tomographic scans. J Bone Joint Surg Am 2009; 91: 1882-9. https://doi.org/10.2106/JBJS.H.01199
  22. Stewart FA, Akleyev AV, Hauer-Jensen M, Hendry JH, Kleiman NJ, Macvittie TJ, et al. ICRP publication 118: ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs--threshold doses for tissue reactions in a radiation protection context. Ann ICRP 2012; 41: 1-322.
  23. International Commission on Radiological Protection (ICRP). Statement on tissue reactions. Approved by the commission on April 21, 2011. ICRP ref 4825-3093-1464. Ottawa, International Commission on Radiological Protection. 2011.
  24. Mahesh M. Fluoroscopy: patient radiation exposure issues. Radiographics 2001; 21: 1033-45. https://doi.org/10.1148/radiographics.21.4.g01jl271033
  25. Manchikanti L, Cash KA, Moss TL, Rivera J, Pampati V. Risk of whole body radiation exposure and protective measures in fluoroscopically guided interventional techniques: a prospective evaluation. BMC Anesthesiol 2003; 3: 2. https://doi.org/10.1186/1471-2253-3-2
  26. Botwin KP, Freeman ED, Gruber RD, Torres-Rames FM, Bouchtas CG, Sanelli JT, et al. Radiation exposure to the physician performing fluoroscopically guided caudal epidural steroid injections. Pain Physician 2001; 4: 343-8.
  27. Botwin KP, Thomas S, Gruber RD, Torres FM, Bouchlas CC, Rittenberg JJ, et al. Radiation exposure of the spinal interventionalist performing fluoroscopically guided lumbar transforaminal epidural steroid injections. Arch Phys Med Rehabil 2002; 83: 697-701. https://doi.org/10.1053/apmr.2002.32439
  28. Botwin KP, Fuoco GS, Torres FM, Gruber RD, Bouchlas CC, Castellanos R, et al. Radiation exposure to the spinal interventionalist performing lumbar discography. Pain Physician 2003; 6: 295-300.
  29. Wang RR, Kumar AH, Tanaka P, Macario A. Occupational radiation exposure of anesthesia providers: a summary of key learning points and resident-led radiation safety projects. Semin Cardiothorac Vasc Anesth 2017; 21: 165-71. https://doi.org/10.1177/1089253217692110
  30. Statkiewicz-Sherer MA, Visconti PJ, Ritenour ER. Radiation protection in medical radiography. 3rd ed. St. Louis (MO), Mosby. 1998.
  31. Hanu-Cernat DE, Duarte R, Raphael JH, Mutagi H, Kapur S, Senthil L. Type of interventional pain procedure, body weight, and presence of spinal pathology are determinants of the level of radiation exposure for fluoroscopically guided pain procedures. Pain Pract 2012; 12: 434-9. https://doi.org/10.1111/j.1533-2500.2011.00521.x
  32. Schueler BA. Operator shielding: how and why. Tech Vasc Interv Radiol 2010; 13: 167-71. https://doi.org/10.1053/j.tvir.2010.03.005
  33. Baek SW, Ryu JS, Jung CH, Lee JH, Kwon WK, Woo NS, et al. A randomized controlled trial about the levels of radiation exposure depends on the use of collimation C-arm fluoroscopic-guided medial branch block. Korean J Pain 2013; 26: 148-53. https://doi.org/10.3344/kjp.2013.26.2.148
  34. Srinivasan D, Than KD, Wang AC, La Marca F, Wang PI, Schermerhorn TC, et al. Radiation safety and spine surgery: systematic review of exposure limits and methods to minimize radiation exposure. World Neurosurg 2014; 82: 1337-43. https://doi.org/10.1016/j.wneu.2014.07.041
  35. National Council on Radiation Protection and Measurements. Radiation dose management for fluoroscopically-guided interventional medical procedures. NCRP report 168. Bethesda (MD), National Council on Radiation Protection and Measurements. 2012.
  36. Chou LB, Cox CA, Tung JJ, Harris AH, Brooks-Terrell D, Sieh W. Prevalence of cancer in female orthopaedic surgeons in the United States. J Bone Joint Surg Am 2010; 92: 240-4.
  37. Klein LW, Miller DL, Balter S, Laskey W, Haines D, Norbash A, et al. Occupational health hazards in the interventional laboratory time for a safer environment: time for a safer environment. J Vasc Interv Radiol 2009; 20: 147-52. https://doi.org/10.1016/j.jvir.2008.10.015
  38. Alexandre D, Prieto M, Beaumont F, Taiar R, Polidori G. Wearing lead aprons in surgical operating rooms: ergonomic injuries evidenced by infrared thermography. J Surg Res 2017; 209: 227-33. https://doi.org/10.1016/j.jss.2016.10.019
  39. Klein LW, Tra Y, Garratt KN, Powell W, Lopez-Cruz G, Chambers C, et al. Occupational health hazards of interventional cardiologists in the current decade: results of the 2014 SCAI membership survey. Catheter Cardiovasc Interv 2015; 86: 913-24. https://doi.org/10.1002/ccd.25927
  40. Dixon RG, Khiatani V, Statler JD, Walser EM, Midia M, Miller DL, et al. Society of Interventional Radiology: Occupational Back and Neck Pain and the Interventional Radiologist. J Vasc Interv Radiol 2017; 28: 195-9. https://doi.org/10.1016/j.jvir.2016.10.017
  41. Papadopoulos N, Papaefstathiou C, Kaplanis PA, Menikou G, Kokona G, Kaolis D, et al. Comparison of lead-free and conventional X-ray aprons for diagnostic radiology. World congress on medical physics and biomedical engineering. Munich, Germany. New York (NY), Springer. 2009. pp 544-6.
  42. Sawdy JM, Gocha MD, Olshove V, Chisolm JL, Hill SL, Phillips A, et al. Radiation protection during hybrid procedures: innovation creates new challenges. J Invasive Cardiol 2009; 21: 437-40.
  43. Badawy MK, Deb P, Chan R, Farouque O. A review of radiation protection solutions for the staff in the cardiac catheterisation laboratory. Heart Lung Circ 2016; 25: 961-7. https://doi.org/10.1016/j.hlc.2016.02.021
  44. Ryu JS, Baek SW, Jung CH, Cho SJ, Jung EG, Kim HK, et al. The survey about the degree of damage of radiation-protective shields in operation room. Korean J Pain 2013; 26: 142-7. https://doi.org/10.3344/kjp.2013.26.2.142
  45. Devalia KL, Peter VK, Madanur MA, Braithwaite IJ. Exposure of the thyroid to radiation during routine orthopaedic procedures. Acta Orthop Belg 2006; 72: 615-20.
  46. Muller LP, Suffner J, Wenda K, Mohr W, Rommens PM. Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing. Injury 1998; 29: 461-8. https://doi.org/10.1016/S0020-1383(98)00088-6
  47. Health risks from exposure to low levels of Ionizing radiation: BEIR VII, phase I, letter report. Washington, D.C., National Academies Press. 1998.
  48. Lee SY, Min E, Bae J, Chung CY, Lee KM, Kwon SS, et al. Types and arrangement of thyroid shields to reduce exposure of surgeons to ionizing radiation during intraoperative use of C-arm fluoroscopy. Spine 2013; 38: 2108-12. https://doi.org/10.1097/BRS.0b013e3182a8270d
  49. Iglesias ML, Schmidt A, Ghuzlan AA, Lacroix L, Vathaire F, Chevillard S, et al. Radiation exposure and thyroid cancer: a review. Arch Endocrinol Metab 2017; 61: 180-7. https://doi.org/10.1590/2359-3997000000257
  50. Gendelberg D, Hennrikus W, Slough J, Armstrong D, King S. A radiation safety training program results in reduced radiation exposure for orthopaedic residents using the mini C-arm. Clin Orthop Relat Res 2016; 474: 580-4. https://doi.org/10.1007/s11999-015-4631-0
  51. Frederick-Dyer KC, Faulkner AR, Chang TT, Heidel RE, Pasciak AS. Online training on the safe use of fluoroscopy can result in a significant decrease in patient dose. Acad Radiol 2013; 20: 1272-7. https://doi.org/10.1016/j.acra.2013.07.008
  52. Tuncer N, Kuyucu E, Sayar S, Polat G, Erdil I, Tuncay I. Orthopedic surgeons' knowledge regarding risk of radiation exposition: a survey analysis. SICOT J 2017; 3: 29. https://doi.org/10.1051/sicotj/2017008
  53. Lynskey GE 3rd, Powell DK, Dixon RG, Silberzweig JE. Radiation protection in interventional radiology: survey results of attitudes and use. J Vasc Interv Radiol 2013; 24: 1547-1551.e3. https://doi.org/10.1016/j.jvir.2013.05.039
  54. Slegers AS, Gultuna I, Aukes JA, van Gorp EJ, Blommers FM, Niehof SP, et al. Coaching reduced the radiation dose of pain physicians by half during interventional procedures. Pain Pract 2015; 15: 400-6. https://doi.org/10.1111/papr.12251

Cited by

  1. Comparison of the Clinical Outcomes of an Ultrasound-Guided and C-Arm Guided Cervical Nerve Root Block vol.55, pp.1, 2018, https://doi.org/10.4055/jkoa.2020.55.1.78
  2. Strategies to Reduce Radiation Exposure in Electrophysiology and Interventional Cardiology vol.13, pp.2, 2018, https://doi.org/10.15420/usc.2019.21.2
  3. MEASUREMENT OF RADIATION DOSE TO THE EYE LENS IN NON-ENHANCED CT SCANS OF THE BRAIN vol.195, pp.1, 2018, https://doi.org/10.1093/rpd/ncab118