DOI QR코드

DOI QR Code

정수처리용 세라믹 분리막의 막오염 물질의 제거 효율 향상을 위한 스팀세정 기법 개발

Development of Steam Cleaning Technique to Improve Removal Efficiency of Membrane Fouling Matter in Water Treatment Process Using Ceramic Membrane

  • 강준석 (명지대학교 환경에너지공학과) ;
  • 박서경 (명지대학교 환경에너지공학과) ;
  • 이정은 (명지대학교 환경에너지공학과) ;
  • 강소연 (명지대학교 환경에너지공학과) ;
  • 이정준 (명지대학교 환경에너지공학과) ;
  • 쿠엔 보 (명지대학교 환경에너지공학과) ;
  • 김한승 (명지대학교 환경에너지공학과)
  • Kang, Joon-Seok (Department of Environmental Engineering and Energy, Myongji University) ;
  • Park, Seo Gyeong (Department of Environmental Engineering and Energy, Myongji University) ;
  • Lee, Jeong Eun (Department of Environmental Engineering and Energy, Myongji University) ;
  • Kang, So Yeon (Department of Environmental Engineering and Energy, Myongji University) ;
  • Lee, Jeong Jun (Department of Environmental Engineering and Energy, Myongji University) ;
  • Quyen, Vo Thi Kim (Department of Environmental Engineering and Energy, Myongji University) ;
  • Kim, Han-Seung (Department of Environmental Engineering and Energy, Myongji University)
  • 투고 : 2018.11.01
  • 심사 : 2018.11.30
  • 발행 : 2018.12.31

초록

This research has developed a high temperature steam cleaning technology using a ceramic membrane with durability against temperature and pressure conditions. In steam cleaning, steam of $120^{\circ}C$ is injected into the ceramic membrane to induce pyrolysis by the endothermic reaction to remove fouling from the membrane. The water quality of raw water was adjusted to turbidity 10, 25 NTU and DOC 2.5 mg/L, and the membrane was uniformly fouled by constant pressure operation at 100, 200, and 300 kPa. Physical backwashing was performed with water and air at a pressure of 500 kPa and steam at $120^{\circ}C$ was injected for 0 to 5 minutes. As the turbidity concentration and the operating pressure increased, the flux decreased by 0.7 to 14.4%. It is confirmed that 10.7 to 53.8% recovery is possible than physical cleaning at the injection of steam for 3 minutes, so it is considered that the steam cleaning of the ceramic membrane is effective. Compared with CEB after NaOCl (300 mg/L) filtration at 25 NTU and 300 kPa of turbidity, the steam cleaning result for 3 minutes was similar to 46.7% of CEB for 3 hours. It has been confirmed that steam cleaning is suitable for a ceramic membrane having excellent heat resistance against high temperature. It was considered to have better cleaning efficiency as compared with general physical backwashing.

키워드

과제정보

연구 과제 주관 기관 : 환경부

참고문헌

  1. Schneider, C., John, P., Huehner, R.(2011). "Removal of Manganese by Microfiltration in a Water Treatment Plant", Proceedings of the 2011 Membrane Technology Conference, AWWA&IWA, San Antonio, Texas USA.
  2. Yang, H. J., Yi, S. H. Moon, K. R. (2017). A Study on Operating Condition on Test-Bed Plant using Membrane filtration of D Water Treatment Plant in Gwang-Ju, J.KSEE, 39(3), pp. 155-163.
  3. Choi, K. H., Park, J. Y., Kim, S. H., Kim, J. S., Kang, L. S. (2013). Application of Ceramic MF Membrane at the Slow Sand Filtration Process, J.KSEE, 35(12), pp. 877-882.
  4. Korea Environment Corporation(2017). Development of Membrane Filtration Water Treatment Facility Technical Inspection Manual
  5. Lee, H. W., An, K. H., Choi, J. S., Kim, S. K., Oh, H. J. (2012). Effect of Trand-Membrane Pressure on Reversible and Irreversible Fouling Formation of Ceramic Membrane, J. KSEE, 34(9), pp. 637-643.
  6. Kang, J. S., Park, S. K., Lee, J. J., Kim, H. S.(2018). Effects of membrane fouling formation by feed water quality and membrane flux in water treatment process using ceramic membrane, J. KSWW, 32(2), pp. 77-87.
  7. Chang, K. C., Park, S. R., Kim, K. B.(2014). Thermal Load Characteristics of High Temperature Condenser for Steam Heat Pump, Proceedings of the SAREK 2013 Winter Annual Conference, 20 Nov, 2013, The Society of Air-Conditioning and Refrigerating Engineers of Korea, Seoul, Korea.
  8. Lee, N. K., Lee, J. H., Um, S. K.(2017). Computational Modeling of Multi-Vessel Steam Generator by Similarity Analysis, Proceedings of the KSME 2017 Conference, 1-3 Nov, 2017, The Korean Society of Mechanical Engineers, Jeju, Korea.
  9. Inno Clean, Principle of Saturated steam cleaner http://www.innoclean.co.kr/deault/case/case02_1.php(September 5, 2018).
  10. Charpin, J., Bergez, P., Valin, F., Barnier, H., Maurel, A., Martinate, J. M. (1987). Inorganic membranes : Preparation, Characterization, Specific Application, High Tech Ceramics(P. Vincenzini, ed.), Elsevier, Amsterdam, pp. 2211-2225.
  11. Kang, J. S., Song, J. Y., Park, S. K., Jeong, A. Y., Lee, J. J., Seo, I. S., Chae, S. H., Kim, S. S., Kim. H. S. (2017). Application of coagulation pretreatment for enhancing the performance of ceramic membrane filtration, J. KSWW, 31(6), pp. 501-510.
  12. Kim, E. O. (1993). Application of Ceramic Membrane, J. Korean Membrane, 3(1), pp. 12-21.
  13. Shimizu, Y., Matsushta, K., Miura, I., Yazawa, T., Eguchi, K.(1988). Characterization of pore geometry of alumina membranes, J. JPN. Ceram. Soc., 96, pp. 556-560. https://doi.org/10.2109/jcersj.96.556
  14. Lee, H. C., Park, J. Y., Yoon, D. Y.(2009). Advanced water treatment of high turbid source by hybrid module of ceramic microfiltration and activated carbon adsorption : Effect of organic/inorganic materials, Korean J. Chem. Eng., 26(3), pp. 697-701. https://doi.org/10.1007/s11814-009-0116-8
  15. Park, M. K., Choi, S. I.(2008), Utility Estimation of Pre-filtration on the Membrane Water Treatment Process, J. KSWW, 22(4), pp. 445-448.
  16. Kim, S. H.(2013). A process diagnosis method for membrane water treatment plant using a constant flux membrane fouling model, J. KSWW, 27(1), pp. 139-146.