Acknowledgement
Supported by : Yonsei University College of Dentistry
References
- Lee DW, Kim CK, Park KH, et al. Non-invasive method to measure the length of soft tissue from the top of the papilla to the crestal bone. J Periodontol. 2005; 76: 1311-1314. https://doi.org/10.1902/jop.2005.76.8.1311
- Lee DW, Park KH, Moon IS. Dimension of interproximal soft tissue between adjacent implants in two distinctive implant systems. J Periodontol. 2006; 77: 1080-1084. https://doi.org/10.1902/jop.2006.050351
- Lee DW, Huh JK, Park KH, et al. Comparison of interproximal soft tissue height for single implants and contra-lateral natural teeth. Clin Oral Implants Res. 2009; 20: 1320-1325. https://doi.org/10.1111/j.1600-0501.2009.01737.x
- Claffey N, Shanley D. Relationship of gingival thickness and bleeding to loss of probing attachment in shallow sites following nonsurgical periodontal therapy. J Clin Periodontol. 1986; 13: 654-657. https://doi.org/10.1111/j.1600-051X.1986.tb00861.x
- Foushee DG, Moriarty JD, Simpson DM. Effects of Mandibular Orthognathic Treatment on Mucogingival Tissues. J Periodontol. 1985; 56: 727-733. https://doi.org/10.1902/jop.1985.56.12.727
- Ronay V, Sahrmann P, Bindl A, et al. Current status and perspectives of mucogingival soft tissue measurement methods. J Esthet Dent. 2011; 23: 146-156. https://doi.org/10.1111/j.1708-8240.2011.00424.x
- Scarfe WC, Farman AG, Sukovic P. Clinical applications of cone-beam computed tomography in dental practice. J Can Dent Assoc. 2006; 72: 75-80.
- Guerrero ME, Jacobs R, Loubele M, et al. State-of-the-art on cone beam CT imaging for preoperative planning of implant placement. Clin Oral Investig. 2006; 10: 1-7. https://doi.org/10.1007/s00784-005-0031-2
- Januario AL, Barriviera M, Duarte WR. Soft Tissue Cone-Beam Computed Tomography: A Novel Method for the Measurement of Gingival Tissue and the Dimensions of the Dentogingival Unit. J Esthet Restor Dent. 2008; 20: 366-373. https://doi.org/10.1111/j.1708-8240.2008.00210.x
- Barriviera M, Duarte WR, Januario AL, et al. A new method to assess and measure palatal masticatory mucosa by cone-beam computerized tomography. J Clin Periodontol. 2009; 36: 564-568. https://doi.org/10.1111/j.1600-051X.2009.01422.x
- Cao J, Hu WJ, Zhang H, et al. A novel technique for measurement of dentogingival tissue by cone beam computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol. 2015; 119: 82-87. https://doi.org/10.1016/j.oooo.2014.10.022
- Silva JNN, Andrade PF, Sotto-Maior BS, et al. Influence of lip retraction on the cone beam computed tomography assessment of bone and gingival tissues of the anterior maxilla. Oral Surg Oral Med Oral Pathol Oral Radiol. 2017; 123: 714-720. https://doi.org/10.1016/j.oooo.2017.02.005
- Ueno D, Sato J, Igarashi C, et al. Accuracy of oral mucosal thickness measurements using spiral computed tomography. J Periodontol. 2011; 82: 829-836. https://doi.org/10.1902/jop.2010.100160
- Wara-aswapati N, Pitiphat W, Chandrapho N, et al. Thickness of palatal masticatory mucosa associated with age. J Periodontol. 2001; 72: 1407-1412. https://doi.org/10.1902/jop.2001.72.10.1407
- Shrout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psychol Bull. 1979;86: 420. https://doi.org/10.1037/0033-2909.86.2.420
- Fleiss JL. Reliability of measurement. In: Fleiss JL, The Design and Analysis of Clinical Experiments. 1st ed. New York, NY: John Wiley & Sons; 1986. p.1-32.
- Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999; 8: 135-160. https://doi.org/10.1177/096228029900800204
- Webber RL, Ruttimann UE, Heaven TJ. Calibration errors in digital subtraction radiography. J Periodontal Res. 1990; 25: 268-275. https://doi.org/10.1111/j.1600-0765.1990.tb00915.x
- Eger T, Muller HP, Heinecke A. Ultrasonic determination of gingival thickness. J Clin Periodontol 1996; 23: 839-845. https://doi.org/10.1111/j.1600-051X.1996.tb00621.x