DOI QR코드

DOI QR Code

Use of resorbable mesh and fibrin glue for restoration in comminuted fracture of anterior maxillary wall

  • Yang, Jae-Hyuk (Department of Plastic and Reconstructive Surgery, Chonbuk National University Hospital, Chonbuk National University College of Medicine) ;
  • Chang, Suk Choo (Department of Plastic and Reconstructive Surgery, Chonbuk National University Hospital, Chonbuk National University College of Medicine) ;
  • Shin, Jin Yong (Department of Plastic and Reconstructive Surgery, Chonbuk National University Hospital, Chonbuk National University College of Medicine) ;
  • Roh, Si-Gyun (Department of Plastic and Reconstructive Surgery, Chonbuk National University Hospital, Chonbuk National University College of Medicine) ;
  • Lee, Nae-Ho (Department of Plastic and Reconstructive Surgery, Chonbuk National University Hospital, Chonbuk National University College of Medicine)
  • Received : 2018.06.15
  • Accepted : 2018.08.01
  • Published : 2018.09.20

Abstract

Background: The facial bone has a complex structure compared to other bones, and various types of fractures can occur due to its characteristics. Among them, in comminuted fractures of anterior maxillary wall, multiple depressed and impacted bony segments cannot be reduced easily when performing internal fixation using plates and screws or wires, and inadequate restoration leads to a range of complications. This paper introduces an alternative technique using a resorbable mesh with fibrin glue to restore comminuted fractures of anterior maxillary wall. Methods: Thirteen patients were diagnosed with comminuted fractures of anterior maxillary wall between March 2017 and February 2018 in the authors' hospital. All patients with comminuted fractures of anterior maxillary wall underwent restoration using resorbable mesh with fibrin glue. The patients' demographics, causes of facial trauma, mean operation time, length of hospital stay, follow-up period, and complications were recorded. Results: No major complications and only one hypoesthesia of the skin area was noted. Three months after surgery, the hypoesthesia recovered completely. After surgery (mean, 3.9 months; range, 2-12 months), computed tomography showed that the bone fragments in all patients were fixed successfully in their anatomical places. Conclusion: In comminuted fractures of anterior maxillary wall, the use of a resorbable mesh with fibrin glue can be an advantageous and effective method for a successful restoration without complications.

Keywords

References

  1. Mankad PS, Codispoti M. The role of fibrin sealants in hemostasis. Am J Surg 2001;182(2 Suppl):21S-28S. https://doi.org/10.1016/S0002-9610(01)00773-5
  2. Mooney E, Loh C, Pu LL; ASPS/PSEF Technology Assessment Committee. The use of fibrin glue in plastic surgery. Plast Reconstr Surg 2009;124:989-92. https://doi.org/10.1097/PRS.0b013e3181b039a3
  3. Beierlein W, Scheule AM, Antoniadis G, Braun C, Schosser R. An immediate, allergic skin reaction to aprotinin after reexposure to fibrin sealant. Transfusion 2000;40:302-5. https://doi.org/10.1046/j.1537-2995.2000.40030302.x
  4. Shetty P, Senthil Kumar G, Baliga M, Uppal N. Options in orbital floor reconstruction in blowout fractures: a review of ten cases. J Maxillofac Oral Surg 2009;8:137-40. https://doi.org/10.1007/s12663-009-0034-7
  5. Top H, Aygit C, Sarikaya A, Karaman D, Firat MF. Evaluation of maxillary sinus after treatment of midfacial fractures. J Oral Maxillofac Surg 2004;62:1229-36. https://doi.org/10.1016/j.joms.2003.12.034
  6. Bratton EM, Durairaj VD. Orbital implants for fracture repair. Curr Opin Ophthalmol 2011;22:400-6. https://doi.org/10.1097/ICU.0b013e3283499409
  7. Smith B, Regan WF Jr. Blow-out fracture of the orbit: mechanism and correction of internal orbital fracture. Am J Ophthalmol 1957;44:733-9. https://doi.org/10.1016/0002-9394(76)90774-1
  8. Radosevich M, Goubran HI, Burnouf T. Fibrin sealant: scientific rationale, production methods, properties, and current clinical use. Vox Sang 1997;72:133-43. https://doi.org/10.1159/000461980
  9. Song SH, Kyung H, Oh SH, Kang N. Fixation of fractured anterior wall of maxillary sinus using fibrin glue in a zygomaticomaxillary complex fracture. J Craniofac Surg 2014;25:919-21. https://doi.org/10.1097/SCS.0000000000000663
  10. Jo EJ, Yang HJ, Kim JH. Fixation of fractured inferior orbital wall using fibrin glue in inferior blowout fracture surgery. J Craniofac Surg 2015;26:e33-6. https://doi.org/10.1097/SCS.0000000000001293
  11. Hutmacher DW, Schantz T, Zein I, Ng KW, Teoh SH, Tan KC. Mechanical properties and cell cultural response of polycaprolactone scaffolds designed and fabricated via fused deposition modeling. J Biomed Mater Res 2001;55:203-16. https://doi.org/10.1002/1097-4636(200105)55:2<203::AID-JBM1007>3.0.CO;2-7
  12. Ng SG, Madill SA, Inkster CF, Maloof AJ, Leatherbarrow B. Medpor porous polyethylene implants in orbital blowout fracture repair. Eye (Lond) 2001;15(Pt 5):578-82. https://doi.org/10.1038/eye.2001.188
  13. Ozturk S, Sengezer M, Isik S, Turegun M, Deveci M, Cil Y. Long-term outcomes of ultra-thin porous polyethylene implants used for reconstruction of orbital floor defects. J Craniofac Surg 2005;16:973-7. https://doi.org/10.1097/01.scs.0000179744.91165.3a
  14. Jacobs CA, Lin AY. A new classification of three-dimensional printing technologies: systematic review of three-dimensional printing for patient-specific craniomaxillofacial surgery. Plast Reconstr Surg 2017;139:1211-20. https://doi.org/10.1097/PRS.0000000000003232

Cited by

  1. Delayed reconstruction of posttraumatic facial deformities vol.61, pp.12, 2018, https://doi.org/10.5124/jkma.2018.61.12.740