Acknowledgement
Supported by : National Research Foundation
References
- Chua HR, Xiang L, Chow PY, et al. Quantifying acute changes in volume and nutritional status during haemodialysis using bioimpedance analysis. Nephrology (Carlton) 17:695-702, 2012 https://doi.org/10.1111/j.1440-1797.2012.01653.x
- Davies SJ, Davenport A. The role of bioimpedance and biomarkers in helping to aid clinical decision-making of volume assessments in dialysis patients. Kidney Int 86:489-496, 2014 https://doi.org/10.1038/ki.2014.207
- Di Iorio BR, Scalfi L, Terracciano V, Bellizzi V. A systematic evaluation of bioelectrical impedance measurement after hemodialysis session. Kidney Int 65:2435-2440, 2004 https://doi.org/10.1111/j.1523-1755.2004.00660.x
- Broers NJ, Martens RJ, Cornelis T, et al. Body composition in dialysis patients: a functional assessment of bioimpedance using different prediction models. J Ren Nutr 25:121-128, 2015 https://doi.org/10.1053/j.jrn.2014.08.007
- Wahba IM, Bennett WM. Increased vascular resistance and not salt retention characterizes cyclosporine A-induced hypertension: report in an anuric patient. Am J Transplant 7:2042-2046, 2007 https://doi.org/10.1111/j.1600-6143.2007.01871.x
- Panorchan K, Nongnuch A, El-Kateb S, Goodlad C, Davenport A. Changes in muscle and fat mass with haemodialysis detected by multi-frequency bioelectrical impedance analysis. Eur J Clin Nutr 69:1109-1112, 2015 https://doi.org/10.1038/ejcn.2015.90
- Cunningham JJ. Body composition as a determinant of energy expenditure: a synthetic review and a proposed general prediction equation. Am J Clin Nutr 54:963-969, 1991 https://doi.org/10.1093/ajcn/54.6.963
- Thanakitcharu P, Jirajan B. Early detection of subclinical edema in chronic kidney disease patients by bioelectrical impedance analysis. J Med Assoc Thai 97 Suppl 11:S1-S10, 2014
- Papakrivopoulou E, Booth J, Pinney J, Davenport A. Comparison of volume status in asymptomatic haemodialysis and peritoneal dialysis outpatients. Nephron Extra 2:48-54, 2012 https://doi.org/10.1159/000337338
- Castellano S, Palomares I, Molina M, et al. Clinical, analytical and bioimpedance characteristics of persistently overhydrated haemodialysis patients. Nefrologia 34:716-723, 2014
- Davenport A, Willicombe M. Comparison of fluid status in patients treated by different modalities of peritoneal dialysis using multi-frequency bioimpedance. Int J Artif Organs 32:779-786, 2009 https://doi.org/10.1177/039139880903201103
- Furstenberg A, Davenport A. Comparison of multifrequency bioelectrical impedance analysis and dual-energy X-ray absorptiometry assessments in outpatient hemodialysis patients. Am J Kidney Dis 57:123-129, 2011 https://doi.org/10.1053/j.ajkd.2010.05.022
- Garagarza C, Joao-Matias P, Sousa-Guerreiro C, et al. Nutritional status and overhydration: can bioimpedance spectroscopy be useful in haemodialysis patients? Nefrologia 33:667-674, 2013
- Kotanko P, Levin NW, Zhu F. Current state of bioimpedance technologies in dialysis. Nephrol Dial Transplant 23:808-812, 2008
- Plum J, Schoenicke G, Kleophas W, et al. Comparison of body fluid distribution between chronic haemodialysis and peritoneal dialysis patients as assessed by biophysical and biochemical methods. Nephrol Dial Transplant 16:2378-2385, 2001 https://doi.org/10.1093/ndt/16.12.2378
- Ikizler TA. The use and misuse of serum albumin as a nutritional marker in kidney disease. Clin J Am Soc Nephrol 7:1375-1377, 2012 https://doi.org/10.2215/CJN.07580712
- Marcelli D, Usvyat LA, Kotanko P, et al. Body composition and survival in dialysis patients: results from an international cohort study. Clin J Am Soc Nephrol 10:1192-1200, 2015 https://doi.org/10.2215/CJN.08550814
- Fein PA, Gundumalla G, Jorden A, Matza B, Chattopadhyay J, Avram MM. Usefulness of bioelectrical impedance analysis in monitoring nutrition status and survival of peritoneal dialysis patients. Adv Perit Dial 18:195-199, 2002
- Genton L, Norman K, Spoerri A, et al. Bioimpedance-derived phase angle and mortality among older people. Rejuvenation Res 20:118-124, 2016
- Anderson LJ, Erceg DN, Schroeder ET. Utility of multi-frequency bioelectrical impedance compared to deuterium dilution for assessment of total body water. Nutr Diet 72:183-189, 2015 https://doi.org/10.1111/1747-0080.12130
Cited by
- Association of Nutritional Assessment by Phase Angle With Mortality in Kidney Transplant Patients in an 8-Year Follow-Up vol.29, pp.4, 2019, https://doi.org/10.1177/1526924819873906
- Water Distribution Changes in Complex Decongestive Treatment for Leg Lymphedema: Quantitative Evaluation by Direct Segmental Multi-frequency Bioimpedance Analysis vol.31, pp.1, 2018, https://doi.org/10.7134/phlebol.19-18
- Hemodialysis—Nutritional Flaws in Diagnosis and Prescriptions. Could Amino Acid Losses Be the Sharpest “Sword of Damocles”? vol.12, pp.6, 2018, https://doi.org/10.3390/nu12061773
- Comparison between lung ultrasonography and current methods for volume assessment in Asian chronic hemodialysis patients vol.24, pp.4, 2020, https://doi.org/10.1111/hdi.12871
- Differences in pharmacological property between combined therapy of the vasopressin V2-receptor antagonist tolvaptan plus furosemide and monotherapy of furosemide in patients with hospitalized heart f vol.76, pp.5, 2018, https://doi.org/10.1016/j.jjcc.2020.05.012
- Extracellular water/total body water ratio as predictor of mortality in hemodialysis patients vol.43, pp.1, 2018, https://doi.org/10.1080/0886022x.2021.1922442
- Association of Prescription With Body Composition and Patient Outcomes in Incident Peritoneal Dialysis Patients vol.8, pp.None, 2021, https://doi.org/10.3389/fmed.2021.737165
- Body Composition Changes Following Dialysis Initiation and Cardiovascular and Mortality Outcomes in CRIC (Chronic Renal Insufficiency Cohort): A Bioimpedance Analysis Substudy vol.3, pp.3, 2018, https://doi.org/10.1016/j.xkme.2020.12.008