참고문헌
- Foulks GN. Glaucoma associated with penetrating keratoplasty. Ophthalmology 1987;94:871-4. https://doi.org/10.1016/S0161-6420(87)33542-0
- Goldberg DB, Schanzlin DJ, Brown SI. Incidence of increased intraocularpressure after keratoplasty. Am J Ophthalmol 1981;92:372-7. https://doi.org/10.1016/0002-9394(81)90527-4
- Irvine AR, Kaufman HE. Intraocular pressure following penetrating keratoplasty. Am J Ophthalmol 1969;68:835-44. https://doi.org/10.1016/0002-9394(69)94577-2
- Kohlhaas M, Boehm AG, Spoerl E, et al. Effect of central corneal thickness, corneal curvature, and axial length on applanation tonometry. Arch Ophthalmol 2006;124:471-6. https://doi.org/10.1001/archopht.124.4.471
- Liu J, Roberts CJ. Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis. J Cataract Refract Surg 2005;31:146-55. https://doi.org/10.1016/j.jcrs.2004.09.031
- Broman AT, Congdon NG, Bandeen-Roche K, Quigley HA. Influence of corneal structure, corneal responsiveness, and other ocular parameters on tonometric measurement of intraocular pressure. J Glaucoma 2007;16:581-8. https://doi.org/10.1097/IJG.0b013e3180640f40
- Kageyama M, Hirooka K, Baba T, Shiraga F. Comparison of ICare rebound tonometer with noncontact tonometer in healthy children. J Glaucoma 2011;20:63-6. https://doi.org/10.1097/IJG.0b013e3181d12dc4
- Pakrou N, Gray T, Mills R, et al. Clinical comparison of the Icare tonometer and Goldmann applanation tonometry. J Glaucoma 2008;17:43-7. https://doi.org/10.1097/IJG.0b013e318133fb32
- Shields MB. The non-contact tonometer. Its value and limitations. Surv Ophthalmol 1980;24:211-9. https://doi.org/10.1016/0039-6257(80)90042-9
- Vernon SA. Intra-eye pressure range and pulse profiles in normal with the Pulsair non-contact tonometer. Eye (Lond) 1993;7(Pt 1):134-7. https://doi.org/10.1038/eye.1993.28
- Zhang Y, Zhao JL, Bian AL, et al. Effects of central corneal thickness and corneal curvature on measurement of intraocular pressure with Goldmann applanation tonometer and non-contact tonometer. Zhonghua Yan Ke Za Zhi 2009;45:713-8.
- Moreno-Montanes J, Gosende I, Caire J, Garcia-Granero M. Comparation of the new rebound tonometer IOPen and the Goldmann tonometer, and their relationship to corneal properties. Eye (Lond) 2011;25:50-6. https://doi.org/10.1038/eye.2010.137
- Sahin A, Basmak H, Niyaz L, Yildirim N. Reproducibility and tolerability of the ICare rebound tonometer in school children. J Glaucoma 2007;16:185-8. https://doi.org/10.1097/IJG.0b013e31802fc6bc
- Moreno-Montanes J, Olmo N, Zarranz-Ventura J, Heras-Mulero H. Dynamic contour tonometry in eyes after penetrating keratoplasty. Cornea 2009;28:836-7.
- Rao VJ, Gnanaraj L, Mitchell KW, Figueiredo FC. Clinical comparison of ocular blood flow tonometer, Tonopen, and Goldmann applanation tonometer for measuring intraocular pressure in postkeratoplasty eyes. Cornea 2001;20:834-8. https://doi.org/10.1097/00003226-200111000-00011
- Shemesh G, Waisbourd M, Varssano D, et al. Measurements of intraocular pressure by Goldmann tonometry, Tonopen XL, and the transpalpebral tonometer, TGDc-01, after penetrating keratoplasty: a comparative study. Cornea 2009;28:724-28. https://doi.org/10.1097/ICO.0b013e3181930be8
- Geyer O, Mayron Y, Loewenstein A, et al. Tono-Pen tonometry in normal and in post-keratoplasty eyes. Br J Ophthalmol 1992;76:538-40. https://doi.org/10.1136/bjo.76.9.538
- Kirkness CM, Ficker LA. Risk factors for the development of postkeratoplasty glaucoma. Cornea 1992;11:427-32. https://doi.org/10.1097/00003226-199209000-00012
- Fan JC, Chow K, Patel DV, McGhee CN. Corticosteroid-induced intraocular pressure elevation in keratoconus is common following uncomplicated penetrating keratoplasty. Eye (Lond) 2009;23:2056-62. https://doi.org/10.1038/eye.2008.413
- Holladay JT, Allison ME, Prager TC. Goldmann applanation tonometry in patients with regular corneal astigmatism. Am J Ophthalmol 1983;96:90-3. https://doi.org/10.1016/0002-9394(83)90459-2
- Rask G, Behndig A. Effects of corneal thickness, curvature, astigmatism and direction of gaze on Goldmann applanation tonometry readings. Ophthalmic Res 2006;38:49-55. https://doi.org/10.1159/000089762
- Matsumoto T, Makino H, Uozato H, et al. The influence of corneal thickness and curvature on the difference between intraocular pressure measurements obtained with a non-contact tonometer and those with a Goldmann applanation tonometer. Jpn J Ophthalmol 2000;44:691.
- Babalola OE, Kehinde AV, Iloegbunam AC, et al. A comparison of the Goldmann applanation and non-contact (Keeler Pulsair EasyEye) tonometers and the effect of central corneal thickness in indigenous indigenous African eyes. Ophthalmic Physiol Opt 2009;29:182-8. https://doi.org/10.1111/j.1475-1313.2008.00621.x
- Moreno-Montanes J, Garcia N, Fernandez-Hortelano A, Garcia-Layana A. Rebound tonometer compared with goldmann tonometer in normal and pathologic corneas. Cornea 2007;26:427-30. https://doi.org/10.1097/ICO.0b013e318030df6e
- Scuderi GL, Cascone NC, Regine F, et al. Validity and limits of the rebound tonometer (ICare[R]): clinical study. Eur J Ophthalmol 2011;21:251-7. https://doi.org/10.5301/EJO.2010.3712
- Jorge J, Fernandes P, Queiros A, et al. Comparison of the IOPenand iCare rebound tonometers with the Goldmann tonometer in a normal population. Ophthalmic Physiol Opt 2010;30:108-12. https://doi.org/10.1111/j.1475-1313.2009.00697.x
- Poostchi A, Mitchell R, Nicholas S, et al. The iCare rebound tonometer: comparisons with Goldmann tonometry, and influence of central corneal thickness. Clin Exp Ophthalmol 2009;37:687-91. https://doi.org/10.1111/j.1442-9071.2009.02109.x
- Martinez-de-la-Casa JM, Jimenez-Santos M, Saenz-Frances F, et al. Performance of the rebound, noncontact and Goldmann applanation tonometers in routine clinical practice. Acta Ophthalmol 2011;89:676-80. https://doi.org/10.1111/j.1755-3768.2009.01774.x
- Nakamura M, Darhad U, Tatsumi Y, et al. Agreement of rebound tonometer in measuring intraocular pressure with three types of applanation tonometers. Am J Ophthalmol 2006;142:332-4. https://doi.org/10.1016/j.ajo.2006.02.035
- Salvetat ML, Zeppieri M, Miani F, et al. Comparison of ICare tonometer and Goldmann applanation tonometry in normal corneas and in eyes with automated lamellar and penetrating keratoplasty. Eye (Lond) 2011;25:642-50. https://doi.org/10.1038/eye.2011.60
- Brusini P, Salvetat ML, Zeppieri M, et al. Comparison of ICare tonometer with Goldmann applanation tonometer in glaucoma patients. J Glaucoma 2006;15:213-7. https://doi.org/10.1097/01.ijg.0000212208.87523.66
- Davies LN, Bartlett H, Mallen EA, Wolffsohn JS. Clinical evaluation of rebound tonometer. Acta Ophthalmol Scand 2006;84:206-9. https://doi.org/10.1111/j.1600-0420.2005.00610.x