DOI QR코드

DOI QR Code

Establishment of Injection Protocol of Test Bolus for Precise Scan Timing in Canine Abdominal Multi-Phase Computed Tomography

  • Choi, Sooyoung (College of Veterinary Medicine, Kangwon National University) ;
  • Lee, In (Ian Animal Diagnostic Center) ;
  • Choi, Hojung (College of Veterinary Medicine, Chungnam National University) ;
  • Lee, Kija (College of Veterinary Medicine, Kyungpook National University) ;
  • Park, Inchul (College of Veterinary Medicine, Kangwon National University) ;
  • Lee, Youngwon (College of Veterinary Medicine, Chungnam National University)
  • Received : 2018.01.13
  • Accepted : 2018.06.08
  • Published : 2018.06.30

Abstract

This study aimed to establish an injection protocol to determine the precise CT scan timing in canine abdominal multi-phase CT using the test bolus method. Three dynamic scans with different contrast injection parameters were performed using a crossover design in eight normal beagle dogs. A contrast material was administered at a fixed dose of 200 mg iodine/kg as a test bolus for dynamic scans 1 and 2, and 600 mg iodine/kg as a main bolus for dynamic scan 3. The contrast materials were administered with 1 ml/s in dynamic scan 1, and 3 ml/s in dynamic scan 2 and 3. The mean arrival time to the appearance of aortic enhancement in dynamic scan 3 was similar to that in dynamic scan 2, and different significantly to that in dynamic scan 1. The mean arrival time to the peak aortic and pancreatic parenchymal enhancement in dynamic scan 3 was similar to that in dynamic scan 1, and different significantly to that in dynamic scan 2. In multi-phase CT scan, a test bolus should be injected with the same injection duration of a main bolus, to obtain the precise arrival times to peak of arterial or pancreatic parenchymal enhancement.

Keywords

References

  1. Bae KT. Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology 2010; 256: 32-61. https://doi.org/10.1148/radiol.10090908
  2. Bae KT, Heiken JP, Brink JA. Aortic and hepatic contrast medium enhancement at CT. Part I. Prediction with a computer model. Radiology 1998; 207: 647-655. https://doi.org/10.1148/radiology.207.3.9609886
  3. Bae KT, Heiken JP, Brink JA. Aortic and hepatic contrast medium enhancement at CT. Part II. Effect of reduced cardiac output in a porcine model. Radiology 1998; 207: 657-662. https://doi.org/10.1148/radiology.207.3.9609887
  4. Bae KT, Heiken JP, Brink JA. Aortic and hepatic peak enhancement at CT: effect of contrast medium injection rate--pharmacokinetic analysis and experimental porcine model. Radiology 1998; 206: 455-464. https://doi.org/10.1148/radiology.206.2.9457200
  5. Caceres AV, Zwingenberger AL, Hardam E, Lucena JM, Schwarz T. Helical computed tomographic angiography of the normal canine pancreas. Vet Radiol Ultrasound 2006; 47: 270-278. https://doi.org/10.1111/j.1740-8261.2006.00139.x
  6. Choi SY, Choi HJ, Lee KJ, Lee YW. Establishment of optimal scan delay for multi-phase computed tomography using bolustracking technique in canine pancreas. J Vet Med Sci 2015; 77: 1049-1054. https://doi.org/10.1292/jvms.14-0693
  7. Iseri T, Yamada K, Chijiwa K, Nishimura R, Matsunaga S, Fujiwara R, et al. Dynamic computed tomography of the pancreas in normal dogs and in a dog with pancreatic insulinoma. Vet Radiol Ultrasound 2007; 48: 328-331. https://doi.org/10.1111/j.1740-8261.2007.00251.x
  8. Kidoh M, Nakaura T, Awai K, Utsunomiya D, Sakaino N, Harada K, et al. Compact-bolus dynamic CT protocol with a test bolus technique in 64-MDCT coronary angiography: comparison of fixed injection rate and duration protocol. Jpn J Radiol 2013; 31: 115-122. https://doi.org/10.1007/s11604-012-0158-4
  9. Kidoh M, Nakaura T, Nakamura S, Awai K, Utsunomiya D, Namimoto T, et al. Novel contrast-injection protocol for coronary computed tomographic angiography: contrast-injection protocol customized according to the patient's time-attenuation response. Heart Vessels 2014; 29: 149-155. https://doi.org/10.1007/s00380-013-0338-x
  10. Kinns J, Malinowski R, McEvoy F, Schwarz T, Zwingenberger A. Special software applications. In: Schwarz T, Saunders J, editors. Veterinary computed tomography. West Sussex, UK.: John Wiley & Sons Ltd.; 2011. p. 67-74.
  11. Kondo H, Kanematsu M, Goshima S, Miyoshi T, Shiratori Y, Onozuka M, et al. MDCT of the pancreas: optimizing scanning delay with a bolus-tracking technique for pancreatic, peripancreatic vascular, and hepatic contrast enhancement. Am J Roentgenol 2007; 188: 751-756. https://doi.org/10.2214/AJR.06.0372
  12. Mai W, Caceres AV. Dual-phase computed tomographic angiographyh in three dogs with pancreatic insulinoma. Vet Radiol Ultrasound 2008; 49: 141-148. https://doi.org/10.1111/j.1740-8261.2008.00340.x
  13. Makara M, Dennler M, Kuehn K, Kalchofner K, Kircher P. Effect of contrast medium injection duration on peak enhancement and time to peak enhancement of canine pulmonary arteries. Vet Radiol Ultrasound 2011; 52: 605-610. https://doi.org/10.1111/j.1740-8261.2011.01850.x
  14. Tateishi K, Kishimoto M, Shimizu J, Yamada K. A comparison between injection speed and iodine delivery rate in contrast-enhanced computed tomography (CT) for normal beagles. J Vet Med Sci 2008; 70: 1027-1030. https://doi.org/10.1292/jvms.70.1027
  15. Tublin ME, Tessler FN, Cheng SL, Peters TL, McGovern PC. Effect of injection rate of contrast medium on pancreatic and hepatic helical CT. Radiology 1999; 210: 97-101. https://doi.org/10.1148/radiology.210.1.r99ja2197
  16. Zwingenberger AL, Schwarz T. Dual-phase CT angiography of the normal canine portal and hepatic vasculature. Vet Radiol Ultrasound 2004; 45: 117-124. https://doi.org/10.1111/j.1740-8261.2004.04019.x