Acknowledgement
Supported by : Konkuk University
References
- Jin DC, Yun SR, Lee SW, Han SW, Kim W, Park J. Current characteristics of dialysis therapy in Korea: 2015 registry data focusing on elderly patients. Kidney Res Clin Pract 2016;35:204-211. https://doi.org/10.1016/j.krcp.2016.09.006
- Parfrey PS, Harnett JD, Griffiths SM, Gault MH, Barre PE. Congestive heart failure in dialysis patients. Arch Intern Med 1988;148:1519-1525. https://doi.org/10.1001/archinte.1988.00380070037010
- Wizemann V, Wabel P, Chamney P, et al. The mortality risk of overhydration in haemodialysis patients. Nephrol Dial Transplant 2009;24:1574-1579. https://doi.org/10.1093/ndt/gfn707
- Kim YJ, Jeon HJ, Kim YH, et al. Overhydration measured by bioimpedance analysis and the survival of patients on maintenance hemodialysis: a single-center study. Kidney Res Clin Pract 2015;34:212-218. https://doi.org/10.1016/j.krcp.2015.10.006
- Barth C, Boer W, Garzoni D, et al. Characteristics of hypotension-prone haemodialysis patients: is there a critical relative blood volume? Nephrol Dial Transplant 2003;18:1353-1360. https://doi.org/10.1093/ndt/gfg171
- Shoji T, Tsubakihara Y, Fujii M, Imai E. Hemodialysis-associated hypotension as an independent risk factor for two-year mortality in hemodialysis patients. Kidney Int 2004;66:1212-1220. https://doi.org/10.1111/j.1523-1755.2004.00812.x
- Thomson GE, Waterhouse K, McDonald HP Jr, Friedman EA. Hemodialysis for chronic renal failure. Clinical observations. Arch Intern Med 1967;120:153-167. https://doi.org/10.1001/archinte.1967.00300020025002
- Vasko R, Muller GA, Ratliff BB, Jung K, Gauczinski S, Koziolek MJ. Clinical judgment is the most important element in overhydration assessment of chronic hemodialysis patients. Clin Exp Nephrol 2013;17:563-568. https://doi.org/10.1007/s10157-012-0745-9
- Lee SW, Song JH, Kim GA, Lim HJ, Kim MJ. Plasma brain natriuretic peptide concentration on assessment of hydration status in hemodialysis patient. Am J Kidney Dis 2003;41:1257-1266. https://doi.org/10.1016/S0272-6386(03)00358-5
- Ando Y, Yanagiba S, Asano Y. The inferior vena cava diameter as a marker of dry weight in chronic hemodialyzed patients. Artif Organs 1995;19:1237-1242. https://doi.org/10.1111/j.1525-1594.1995.tb02292.x
- Steuer RR, Germain MJ, Leypoldt JK, Cheung AK. Enhanced fluid removal guided by blood volume monitoring during chronic hemodialysis. Artif Organs 1998;22:627-632. https://doi.org/10.1046/j.1525-1594.1998.06036.x
- Schloerb PR, Friis-hansen BJ, Edelman IS, Solomon AK, Moore FD. The measurement of total body water in the human subject by deuterium oxide dilution; with a consideration of the dynamics of deuterium distribution. J Clin Invest 1950;29:1296-1310. https://doi.org/10.1172/JCI102366
- Miller ME, Cosgriff JM, Forbes GB. Bromide space determination using anion-exchange chromatography for measurement of bromide. Am J Clin Nutr 1989;50:168-171. https://doi.org/10.1093/ajcn/50.1.168
- Pierson RN Jr, Wang J, Colt EW, Neumann P. Body composition measurements in normal man: the potassium, sodium, sulfate and tritium spaces in 58 adults. J Chronic Dis 1982;35:419-428. https://doi.org/10.1016/0021-9681(82)90056-X
- Kyle UG, Bosaeus I, De Lorenzo AD, et al. Bioelectrical impedance analysis: part I: review of principles and methods. Clin Nutr 2004;23:1226-1243. https://doi.org/10.1016/j.clnu.2004.06.004
- Hannan WJ, Cowen SJ, Fearon KC, Plester CE, Falconer JS, Richardson RA. Evaluation of multi-frequency bio-impedance analysis for the assessment of extracellular and total body water in surgical patients. Clin Sci (Lond) 1994;86:479-485. https://doi.org/10.1042/cs0860479
- Sartorio A, Malavolti M, Agosti F, et al. Body water distribution in severe obesity and its assessment from eight-polar bioelectrical impedance analysis. Eur J Clin Nutr 2005;59:155-160. https://doi.org/10.1038/sj.ejcn.1602049
- Kuhlmann MK, Zhu F, Seibert E, Levin NW. Bioimpedance, dry weight and blood pressure control: new methods and consequences. Curr Opin Nephrol Hypertens 2005;14:543-549. https://doi.org/10.1097/01.mnh.0000185983.48319.00
- Cha K. Principles of bioelectritical impedance analysis. Seoul (KR): InBody Co. Ltd., 1977:1-8.
- Matthie J, Zarowitz B, De Lorenzo A, et al. Analytic assessment of the various bioimpedance methods used to estimate body water. J Appl Physiol (1985) 1998;84:1801-1816. https://doi.org/10.1152/jappl.1998.84.5.1801
- Buendia R, Seoane F, Lindecrantz K, et al. Estimation of body fluids with bioimpedance spectroscopy: state of the art methods and proposal of novel methods. Physiol Meas 2015;36:2171-2187. https://doi.org/10.1088/0967-3334/36/10/2171
- Tattersall J. Bioimpedance analysis in dialysis: state of the art and what we can expect. Blood Purif 2009;27:70-74.
- Khalil SF, Mohktar MS, Ibrahim F. The theory and fundamentals of bioimpedance analysis in clinical status monitoring and diagnosis of diseases. Sensors (Basel) 2014;14:10895-10928. https://doi.org/10.3390/s140610895
- Lukaski HC, Bolonchuk WW, Hall CB, Siders WA. Validation of tetrapolar bioelectrical impedance method to assess human body composition. J Appl Physiol (1985) 1986;60:1327-1332. https://doi.org/10.1152/jappl.1986.60.4.1327
- Hannan WJ, Cowen SJ, Plester CE, Fearon KC, deBeau A. Comparison of bio-impedance spectroscopy and multi-frequency bio-impedance analysis for the assessment of extracellular and total body water in surgical patients. Clin Sci (Lond) 1995;89:651-658. https://doi.org/10.1042/cs0890651
- Patel RV, Peterson EL, Silverman N, Zarowitz BJ. Estimation of total body and extracellular water in post-coronary artery bypass graft surgical patients using single and multiple frequency bioimpedance. Crit Care Med 1996;24:1824-1828. https://doi.org/10.1097/00003246-199611000-00011
- Olde Rikkert MG, Deurenberg P, Jansen RW, van't Hof MA, Hoefnagels WH. Validation of multi-frequency bioelectrical impedance analysis in detecting changes in fluid balance of geriatric patients. J Am Geriatr Soc 1997;45:1345-1351. https://doi.org/10.1111/j.1532-5415.1997.tb02934.x
- Abbas SR, Zhu F, Levin NW. Bioimpedance can solve problems of fluid overload. J Ren Nutr 2015;25:234-237. https://doi.org/10.1053/j.jrn.2014.10.014
- Bedogni G, Malavolti M, Severi S, et al. Accuracy of an eight-point tactile-electrode impedance method in the assessment of total body water. Eur J Clin Nutr 2002;56:1143-1148. https://doi.org/10.1038/sj.ejcn.1601466
- Chamney PW, Kramer M, Rode C, Kleinekofort W, Wizemann V. A new technique for establishing dry weight in hemodialysis patients via whole body bioimpedance. Kidney Int 2002;61:2250-2258. https://doi.org/10.1046/j.1523-1755.2002.00377.x
- Moissl UM, Wabel P, Chamney PW, et al. Body fluid volume determination via body composition spectroscopy in health and disease. Physiol Meas 2006;27:921-933. https://doi.org/10.1088/0967-3334/27/9/012
- Chertow GM, Lowrie EG, Wilmore DW, et al. Nutritional assessment with bioelectrical impedance analysis in maintenance hemodialysis patients. J Am Soc Nephrol 1995;6:75-81.
- Zhu F, Wystrychowski G, Kitzler T, Thijssen S, Kotanko P, Levin NW. Application of bioimpedance techniques to peritoneal dialysis. Contrib Nephrol 2006;150:119-128.
- Asghar RB, Green S, Engel B, Davies SJ. Relationship of demographic, dietary, and clinical factors to the hydration status of patients on peritoneal dialysis. Perit Dial Int 2004;24:231-239.
- Lindley E, Devine Y, Hall L, et al. A ward-based procedure for assessment of fluid status in peritoneal dialysis patients using bioimpedance spectroscopy. Perit Dial Int 2005;25 Suppl 3:S46-S48.
- Davies SJ, Davenport A. The role of bioimpedance and biomarkers in helping to aid clinical decision-making of volume assessments in dialysis patients. Kidney Int 2014;86:489-496. https://doi.org/10.1038/ki.2014.207
- Konings CJ, Kooman JP, Schonck M, et al. Fluid status, blood pressure, and cardiovascular abnormalities in patients on peritoneal dialysis. Perit Dial Int 2002;22:477-487.
- van de Kerkhof J, Hermans M, Beerenhout C, et al. Reference values for multifrequency bioimpedance analysis in dialysis patients. Blood Purif 2004;22:301-306. https://doi.org/10.1159/000078761
- Wang X, Axelsson J, Lindholm B, Wang T. Volume status and blood pressure in continuous ambulatory peritoneal dialysis patients. Blood Purif 2005;23:373-378. https://doi.org/10.1159/000087194
- Plum J, Schoenicke G, Kleophas W, et al. Comparison of body fluid distribution between chronic haemodialysis and peritoneal dialysis patients as assessed by biophysical and biochemical methods. Nephrol Dial Transplant 2001;16:2378-2385. https://doi.org/10.1093/ndt/16.12.2378
- Piccoli A. Whole body: single frequency bioimpedance. Contrib Nephrol 2005;149:150-161.
- Piccoli A, Rossi B, Pillon L, Bucciante G. A new method for monitoring body fluid variation by bioimpedance analysis: the RXc graph. Kidney Int 1994;46:534-539. https://doi.org/10.1038/ki.1994.305
- Chamney PW, Wabel P, Moissl UM, et al. A whole-body model to distinguish excess fluid from the hydration of major body tissues. Am J Clin Nutr 2007;85:80-89. https://doi.org/10.1093/ajcn/85.1.80
- Fresenius Medical Care. BCM standard. Bad Homburg (DE): Fresenius Medical Care, 2014.
- Onofriescu M, Hogas S, Voroneanu L, et al. Bioimpedance-guided fluid management in maintenance hemodialysis: a pilot randomized controlled trial. Am J Kidney Dis 2014;64:111-118. https://doi.org/10.1053/j.ajkd.2014.01.420
- Chen YC, Chen HH, Yeh JC, Chen SY. Adjusting dry weight by extracellular volume and body composition in hemodialysis patients. Nephron 2002;92:91-96. https://doi.org/10.1159/000064471
- Pillon L, Piccoli A, Lowrie EG, Lazarus JM, Chertow GM. Vector length as a proxy for the adequacy of ultrafiltration in hemodialysis. Kidney Int 2004;66:1266-1271. https://doi.org/10.1111/j.1523-1755.2004.00881.x
- Piccoli A. Identification of operational clues to dry weight prescription in hemodialysis using bioimpedance vector analysis. The Italian Hemodialysis-Bioelectrical Impedance Analysis (HD-BIA) Study Group. Kidney Int 1998;53:1036-1043. https://doi.org/10.1111/j.1523-1755.1998.00843.x
- Onofriescu M, Siriopol D, Voroneanu L, et al. Overhydration, cardiac function and survival in hemodialysis patients. PLoS One 2015;10:e0135691. https://doi.org/10.1371/journal.pone.0135691
- Machek P, Jirka T, Moissl U, Chamney P, Wabel P. Guided optimization of fluid status in haemodialysis patients. Nephrol Dial Transplant 2010;25:538-544. https://doi.org/10.1093/ndt/gfp487
- Moissl U, Arias-Guillen M, Wabel P, et al. Bioimpedance-guided fluid management in hemodialysis patients. Clin J Am Soc Nephrol 2013;8:1575-1582. https://doi.org/10.2215/CJN.12411212
- Zhu F, Kuhlmann MK, Sarkar S, et al. Adjustment of dry weight in hemodialysis patients using intradialytic continuous multifrequency bioimpedance of the calf. Int J Artif Organs 2004;27:104-109. https://doi.org/10.1177/039139880402700205
- Oe B, De Fijter CW, Geers TB, Vos PF, de Vries PM. Hemodialysis (HD) versus peritoneal dialysis (PD): latent overhydration in PD patients? Int J Artif Organs 2002;25:838-843. https://doi.org/10.1177/039139880202500905
- O'Lone EL, Visser A, Finney H, Fan SL. Clinical significance of multi-frequency bioimpedance spectroscopy in peritoneal dialysis patients: independent predictor of patient survival. Nephrol Dial Transplant 2014;29:1430-1437. https://doi.org/10.1093/ndt/gfu049
- Yoon HE, Kwon YJ, Song HC, et al. Overhydration negatively affects quality of life in peritoneal dialysis patients: evidence from a prospective observational study. Int J Med Sci 2016;13:686-695. https://doi.org/10.7150/ijms.16372
- Jang M, Kim WH, Lee JH, et al. Numerical expression of volume status using the bioimpedance ratio in continuous ambulatory peritoneal dialysis patients: a pilot study. Kidney Res Clin Pract 2017;36:290-295. https://doi.org/10.23876/j.krcp.2017.36.3.290
- Foley RN, Parfrey PS, Morgan J, et al. Effect of hemoglobin levels in hemodialysis patients with asymptomatic cardiomyopathy. Kidney Int 2000;58:1325-1335. https://doi.org/10.1046/j.1523-1755.2000.00289.x
- Hur E, Usta M, Toz H, et al. Effect of fluid management guided by bioimpedance spectroscopy on cardiovascular parameters in hemodialysis patients: a randomized controlled trial. Am J Kidney Dis 2013;61:957-965. https://doi.org/10.1053/j.ajkd.2012.12.017
- Middleton RJ, Parfrey PS, Foley RN. Left ventricular hypertrophy in the renal patient. J Am Soc Nephrol 2001; 12:1079-1084.
- Chazot C, Wabel P, Chamney P, Moissl U, Wieskotten S, Wizemann V. Importance of normohydration for the long-term survival of haemodialysis patients. Nephrol Dial Transplant 2012;27:2404-2410. https://doi.org/10.1093/ndt/gfr678
Cited by
- Tissue coefficient of bioimpedance spectrometry as an index to discriminate different tissues in vivo vol.39, pp.3, 2018, https://doi.org/10.1016/j.bbe.2019.08.003
- Collapse of Fluid Balance and Association with Survival in Patients with Advanced Cancer Admitted to a Palliative Care Unit: Preliminary Findings vol.23, pp.4, 2020, https://doi.org/10.1089/jpm.2019.0392
- An update review of intradialytic hypotension: concept, risk factors, clinical implications and management vol.13, pp.6, 2020, https://doi.org/10.1093/ckj/sfaa078
- Trunk Muscle Mass Measured by Bioelectrical Impedance Analysis Reflecting the Cross-Sectional Area of the Paravertebral Muscles and Back Muscle Strength: A Cross-Sectional Analysis of a Prospective Co vol.10, pp.6, 2018, https://doi.org/10.3390/jcm10061187
- Optimal current frequency for the detection of changes in extracellular water in patients on hemodialysis by measurement of total body electrical resistance vol.43, pp.None, 2018, https://doi.org/10.1016/j.clnesp.2021.03.035
- Phase Angle Evaluation of Lung Disease Patients and Its Relationship with Nutritional and Functional Parameters vol.40, pp.6, 2018, https://doi.org/10.1080/07315724.2020.1801535