DOI QR코드

DOI QR Code

Identification and Damping of Resonances in Inverter-based Microgrids

  • Received : 2017.11.03
  • Accepted : 2018.02.20
  • Published : 2018.07.20

Abstract

The application of shunt capacitor banks and underground cables typically induces resonance in power distribution systems. In this study, the propagation of resonance in a microgrid (MG) with inverter-based distributed generators (IBDGs) is investigated. If resonances are not properly damped, then the output current of the inverters may experience distortion via resonance propagation due to the adverse effect of resonances on MG power quality. This study presents a conceptual method for identifying resonances and related issues in multi-inverter systems. For this purpose, existing resonances are identified using modal impedance analysis. However, some resonances may be undetectable when this method is used. Thus, the resonances are investigated using the proposed method based on the frequency response of a closed-loop MG equivalent circuit. After analyzing resonance propagation in the MG, an effective virtual impedance damping method is used in the IBDG control system to damp the resonances. Results demonstrate the effectiveness of the proposed method in compensating for existing resonances.

Keywords

References

  1. J. H. R. Enslin and P. J. M. Heskes, "Harmonic interaction between a large number of distributed power inverters and the distributed network," IEEE Trans. Power Electron., Vol. 19, No. 6, pp. 1586-1593, Nov. 2004. https://doi.org/10.1109/TPEL.2004.836615
  2. J. Agorreta, M. Borrega, J. Lopez, and L. Marroyo, "Modeling and control of N paralleled grid-connected inverters with LCL filters coupled due to grid impedance in PV plants," IEEE Trans. Ind. Electron, Vol. 26, No. 3, pp. 780-780, Mar. 2011.
  3. M. H. Bierhoff and F. W. Fuchs, "Active damping for three-phase PWM rectifiers with high-order line-side filters," IEEE Trans. Ind. Electron, Vol. 56, No. 2, pp. 371-379, Feb. 2010. https://doi.org/10.1109/TIE.2008.2007950
  4. M. Munir, Y. W. Li, and H. Tian, "Improved residential distribution system harmonic compensation scheme using power electronics interfaced DGs," IEEE Trans. Smart Grid, Vol. 7, No. 3, pp. 1191-1203, May 2016. https://doi.org/10.1109/TSG.2016.2535213
  5. M. Munir and Y.W. Li, "Residential distribution system harmonic compensation using pv interfacing inverter," IEEE Trans. on Smart Grid, Vol. 4, No. 2, pp. 816-827, Jun. 2013. https://doi.org/10.1109/TSG.2013.2238262
  6. J. He, Y. W. Li, D. Bosnjak, and B. Harris, "Investigation and resonances damping of multiple PV inverters," in Conf. Rec. IEEE Annu. Appl. Power Electron., pp. 246-253, 2012.
  7. J. He and Y.W. Li, "Generalized closed-loop control (GCC) schemes with embedded virtual impedances for voltage source converters with LC or LCL filters," IEEE Trans. Power Electron, Vol. 27, No. 4, pp. 1850-1861, Apr. 2012. https://doi.org/10.1109/TPEL.2011.2168427
  8. J. He, Y. W. Li, R. Wang, and C. Zhang, "Analysis and mitigation of resonance propagation in grid-connected and islanding MGs," IEEE Trans. Energy Convers., Vol. 30, No. 1, pp. 70-81, Mar. 2015. https://doi.org/10.1109/TEC.2014.2332497
  9. Z. Chen, Y. Chen, J. M. Guerrero, H. Kuang, Y. Huang, L. Zhou, and A. Luo, "Generalized coupling resonance modeling, analysis, and active damping of multi-parallel inverters in MG operating in grid-connected mode," Power Syst. Clean Energy, Vol. 4, No. 1, pp. 63-75, 2016. https://doi.org/10.1007/s40565-016-0184-9
  10. Y. Han, P. Shen, and J. M. Guerrero, "Stationary frame current control evaluations for three-phase grid-connected inverters with pvr-based active damped LCL filters," J. Power Electron., Vol. 16, No. 1, pp. 297-309, Jan. 2016. https://doi.org/10.6113/JPE.2016.16.1.297
  11. J. He, Y.W. Li, D. Bosnjak, and B. Harris, "Investigation and active damping of multiple resonances in a parallel inverter-based MG," IEEE Trans. Power Electronics, Vol. 28, No. 1, pp. 234-246, Jan. 2013. https://doi.org/10.1109/TPEL.2012.2195032
  12. X. Wang, Y. Pang, P. C. Loh, and F. Blaabjerg, "A series-LC-filtered active damper with grid disturbance rejection for ac power-electronics-based power systems," IEEE Trans. Power Electron., Vol. 30, No. 8, pp. 4037-4041, Aug. 2015. https://doi.org/10.1109/TPEL.2014.2382477
  13. I. Lorzadeh, M. S. Firoozabadi, H. Askarian Abyaneh, and J. M. Guerrero, "Active damping techniques for LCLfiltered inverters-based MGs," Proc. of the 10th IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED), pp. 408-414, 2015.
  14. Y. Chen, J. M. Guerrero, Z. Shuai, Z. Chen, L. Zhou, and A. Luo, "Fast reactive power sharing, circulating current and resonance suppression for parallel inverters using resistive-capacitive output impedance," IEEE Trans. Power Electron., Vol. 31, No. 8, pp. 5524-5537, Aug. 2016. https://doi.org/10.1109/TPEL.2015.2493103
  15. Y. Song, X. Wang, and F. Blaabjerg, "High frequency resonance damping of DFIG based wind power system under weak network," IEEE Trans. Power Electron., Vol. 32, No. 3, pp. 1927-1940, Mar. 2017. https://doi.org/10.1109/TPEL.2016.2555846
  16. K. H. Ahmed, A. M. Massoud, S. J. Finney, and B. W. Williams, "A modified stationary reference frame-based predictive current control with zero steady-state error for LCL coupled inverter-based distributed generation systems," IEEE Trans. Ind. Electron., Vol. 58, No. 4, pp. 1359-1370, Apr. 2011. https://doi.org/10.1109/TIE.2010.2050414
  17. F. Wang, J. L. Duarte, M. A. M. Hendrix, and P. F. Ribeiro, "Modeling and analysis of grid harmonic distortion impact of aggregated DG inverters," IEEE Trans. Power Electron., Vol. 26, No. 3, pp. 786-797, Mar. 2011. https://doi.org/10.1109/TPEL.2010.2091286
  18. W. Zhao and G. Chen, "Comparison of active and passive damping methods for application in high power active power filter with LCL-filter," in Conf. Rec. IEEE Int. Conf. Sustainable Power Generation Supply, pp. 1-6, 2010.