References
- J.H. Cho, S.T. Woo, H.G. Lim, E.S. Jung, J.H. Lee, K.W. Seong, et al., "Proposition of a New Implantable Acoustic Sensor Based on Technology Evaluation of Fully Implantable Hearing Aids," Journal of Sensor Science and Technology, Vol. 23, No. 3, pp. 178-184, 2014. https://doi.org/10.5369/JSST.2014.23.3.178
- D.S. Haynes, J.A. Young, G.B. Wanna, and M.E. Glasscock III, "Middle Ear Implantable Hearing Devices: An Overview," Trends Amplification, Vol. 13, No. 3, pp. 206-214, 2009. https://doi.org/10.1177/1084713809346262
- H.J. Ahn, H.G Lim, M.N. Kim, and J.H Cho, "Design of External Coil System for Reducing Artifact of MR Image due to Implantable Aid," Journal of Korea Multimedia Society, Vol. 19, No. 2, pp. 375-385, 2016. https://doi.org/10.9717/kmms.2016.19.2.375
- T.J. Stewart and A. Belal, "Surgical Anatomy and Pathology of the Round Window," Clinical Otolaryngology, Vol. 6, No. 1, pp. 45-62, 1981. https://doi.org/10.1111/j.1365-2273.1981.tb01785.x
- Med-El GmbH, http://medel.com (accessed Jan., 22, 2018).
- Envoy Medical Co., http://esteemhearing.com (accessed Jan., 22, 2018).
- Cochlear Ltd., http://www.cochlear.com (accessed Jan., 22, 2018).
- V. Colletti, S.D. Soli, M. Carner, and L. Colletti, "Treatment of Mixed Hearing Losses via Implantation of a Vibratory Transducer on the RW," International Journal of Audiology, Vol. 45, No. 10, pp. 600-608, 2006. https://doi.org/10.1080/14992020600840903
- J.H. Spindel, P.R. Lambert, and R.A. Ruth, "The Basis for a Round Window Electromagnetic Implantable Hearing Aid," Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vol. 13, No. 4, pp. 1891-1892, 1991.
- C.S. Stieger, J.J. Rosowski, and H.H. Nakajima, "Comparison of Forward (ear-canal) and Reverse (round-window) Sound Stimulation of the Cochlea," Hearing Research, Vol. 301, pp. 105-114, 2013. https://doi.org/10.1016/j.heares.2012.11.005
- Y. Shimizu, S. Puria, and R.L. Goode, "The Floating Mass Transducer on the Round Window Versus Attachment to an Ossicular Replacement Prosthesis," Otology and Neurotology, Vol. 32, No. 1, pp. 98-103, 2011. https://doi.org/10.1097/MAO.0b013e3181f7ad76
- S. Iwasaki, H. Suzuki, H, Moteki, M. Miyagawa, Y. Takumi, and S. Usami, "Experience with the Vibrant Soundbridge RW-Coupler for Round Window Vibroplasty with Tympanosclerosis," Acta Oto-Laryngology, Vol. 132, No. 6, pp. 676-682, 2012. https://doi.org/10.3109/00016489.2011.649492
- M. Toth, A. Alpar, L. Paronay, and I. Olah, "Development and Surgical Anatomy of the RW Niche," Annals of Anatomy, Vol. 188, No. 2, pp. 93-101, 2005. https://doi.org/10.1016/j.aanat.2005.09.006
- I. Todt, G. Rademacher, J. Wagner, P. Mittmann, D. Basta, and A. Ernst, "Radiological Control of the Floating Mass Transducer Attached to the Round Window," The Scientific World Journal, Vol. 2103, article ID 902945, 2013.
- K. O'Connor and S. Purial, "Middle Ear Cavity and Ear Canal Pressure-driven Stapes Velocity Responses in Human Cadaveric Temporal Bones," Journal of Acoustical Society of America, Vol. 129, No. 3, pp. 1517-1528, 2006.
- Standard Practice for Describing System Output of Implantable Middle Ear Hearing Devices, http://www.astm.org/Standards/F2504.htm (accessed Jan., 22, 2018).