DOI QR코드

DOI QR Code

태양전지모듈 고장 진단 알고리즘을 적용한 모니터링시스템

The Monitoring System with PV Module-level Fault Diagnosis Algorithm

  • 고석환 (한국에너지기술연구원 태양광연구실) ;
  • 소정훈 (한국에너지기술연구원 태양광연구실) ;
  • 황혜미 (한국에너지기술연구원 태양광연구실) ;
  • 주영철 (한국에너지기술연구원 태양광연구실) ;
  • 송형준 (한국에너지기술연구원 태양광연구실) ;
  • 신우균 (한국에너지기술연구원 태양광연구실) ;
  • 강기환 (한국에너지기술연구원 태양광연구실) ;
  • 최정내 (주식회사케이디티 부설연구소) ;
  • 강인철 (주식회사엘스콤 부설연구소)
  • Ko, Suk-Whan (Photovoltaic Laboratory, Korea Institute of Energy Research) ;
  • So, Jung-Hun (Photovoltaic Laboratory, Korea Institute of Energy Research) ;
  • Hwang, Hye-Mi (Photovoltaic Laboratory, Korea Institute of Energy Research) ;
  • Ju, Young-Chul (Photovoltaic Laboratory, Korea Institute of Energy Research) ;
  • Song, Hyung-June (Photovoltaic Laboratory, Korea Institute of Energy Research) ;
  • Shin, Woo-Gyun (Photovoltaic Laboratory, Korea Institute of Energy Research) ;
  • Kang, Gi-Hwan (Photovoltaic Laboratory, Korea Institute of Energy Research) ;
  • Choi, Jung-Rae (Research Institute, KDT Corporation) ;
  • Kang, In-Chul (Research Institute, ELSCOM Corporation)
  • 투고 : 2018.02.19
  • 심사 : 2018.06.17
  • 발행 : 2018.06.30

초록

The objects of PV (Photovoltaic) monitoring system is to reduce the loss of system and operation and maintenance costs. In case of PV plants with configured of centralized inverter type, only 1 PV module might be caused a large loss in the PV plant. For this reason, the monitoring technology of PV module-level that find out the location of the fault module and reduce the system losses is interested. In this paper, a fault diagnosis algorithm are proposed using thermal and electrical characteristics of PV modules under failure. In addition, the monitoring system applied with proposed algorithm was constructed. The wireless sensor using LoRa chip was designed to be able to connect with IoT device in the future. The characteristics of PV module by shading is not failure but it is treated as a temporary failure. In the monitoring system, it is possible to diagnose whether or not failure of bypass diode inside the junction box. The fault diagnosis algorithm are developed on considering a situation such as communication error of wireless sensor and empirical performance evaluation are currently conducting.

키워드

참고문헌

  1. Global Solar PV O&M 2017-2022 Markets, Services and Competitors, GTMresearch, 2017.12.
  2. Photovoltaics and Firefighters' Operations: Best Practices in Selected Countries, Report IEA-PVPS T12-09: 2017.
  3. Planning and Installing Photovoltaic Systems: A guide for installers, Architects and Engineers, 3nd, International Solar Energy Society, German, 2015.
  4. Ko, S. W., Ju, Y. C., So, J. H., Hwang, H. M., Jung, Y. S., and Kang, G. H., The Characteristics of PV Module Under the Partial Shading Condition and with a Failure of Bypass Diode with Short, Journal of the Korean Solar Energy Society, Vol. 36, No. 4, pp. 41-47, 2016. https://doi.org/10.7836/KSES.2016.36.4.041
  5. Ko, S. W., Ju, Y. C., Hwang, H. M., So, J. H., Jung, Y. S., Song, H. J., Song, H. E., Kim, S. H., and Kang, G. H., Electric and Thermal Characteristics of Photovoltaic Modules Under Partial Shading and with a Damaged Bypass Diode, Energy, Vol.128, pp. 232-243, 2017. https://doi.org/10.1016/j.energy.2017.04.030
  6. Shin, W. G., Jung, T. H., Ko, S. W., Ju, Y. C., Chang, H. S., and Kang, G. H., Analysis on Thermal & Electrical Characteristics Variation of PV Module with Damaged Bypass Diodes, Journal of the Korean Solar Energy Society, Vol. 35, No. 4, pp. 67-75, 2015. https://doi.org/10.7836/kses.2015.35.4.067
  7. Park, Y. N., Kang, G. H., Ju, Y. C., Kim, S. H., Ko, S. W., and Jang, G. S., The Monitoring System of Photovoltaic Module Using Fault Diagnosis Sensor, Journal of the Korean Solar Energy Society, Vol. 36, No. 5, pp. 1-10, 2016. https://doi.org/10.7836/kses.2016.36.5.001