DOI QR코드

DOI QR Code

Flexural Performance of RC Beams Strengthened with NSM-GFRP Exposed to High Temperature

GFRP 표면매립공법으로 보강된 RC보의 고온노출 후 휨 성능

  • Received : 2017.11.06
  • Accepted : 2018.03.23
  • Published : 2018.04.30

Abstract

This study evaluated the fire resisting capacity and post-fire serviceability of the concrete beams retrofitted by near surface mounted method(NSM) using GFRP plates. Main parameters in the test are grout materials and fire exposure. For the test, two types of grout materials between concrete substrate and GFRP plate were used; flame resisting epoxy and filling mortar. Four RC beam specimens were made and two of them were exposed to fire according to real scale fire curve proposed KS F 2257. After the fire exposure test, flexural test were performed to investigate the flexural performance of concrete beams including strength and deformation. From the test results, it was found that the beam retrofitted by NSM-GFRP presented higher flexural strength than that of the beam without retrofit, which indicates NSM-GFRP retrofit technologies is effective to maintain flexural strength even after fire exposure. In addition, the specimens grouted by epoxy showed good performance in strength but bad performance in ductility.

Keywords

Acknowledgement

Supported by : 한국연구재단, 국토교통부

References

  1. Meier, U., & Winistorfer, A. (1995). Retrofitting of structures through external bonding of CFRP sheets, Proceedings of the Second International RILEM Symposium, 509-516
  2. Foster, S., & Bisby, L. (2008). Fire survivability of externally bonded FRP Strengthening Systems, Journal of Composites for Construction, 12(5), 553-561. https://doi.org/10.1061/(ASCE)1090-0268(2008)12:5(553)
  3. Seo, S., Oh, J., & Choi, K. (2011). Bond capacity of concrete member strengthened by various methods using FRP plate, Journal of the architectural institute of Korea structure & construction, 27(8), 55-63.
  4. Lim, D. (2008). An experimental study on the flexural behavior of RC beams strengthened with NSM and EBR CFRP strips, Journal of Korea concrete institute, 20(5), 601-609. https://doi.org/10.4334/JKCI.2008.20.5.601
  5. El-Hacha, R., & Rizkalla, S. (2004). Near surface mounted FRP reinforcements for flexural strengthening of concrete Structures, ACI Structural Journal, 101(5), 717-726.
  6. Jung, W. (2009). Flexural behavior of reinforced concrete beams strengthened with NSM CFRP reinforcements considering the equivalent section, Thesis, Myongji University, 217-219.
  7. Korean Industrial Standards(2004), KS M 3381: Testing method for tensile properties of glass fiber reinforced plastics, 1-11
  8. Jung, S. (2010). Flexural strength of RC beams strengthened with GFRP using cementitious filler, Thesis, Soongsil University, 35.
  9. Soliman, E., Kandil, U., & Taha, M. (2015). Investigation of FRP lap spliced using epoxy constaining carbon nanotubes, Journal of Composities for Construction, 19(2), 2015
  10. Korean Industrial Standards(2002), KS M ISO 527-4: Plastics - Determination of tensile properties - Part 4: Test conditions for isotropic and orthotropic fibre-reinforced plastic composites, 1-13
  11. Korean Industrial Standards(2014), KS F 2257-1: Methods of fire resistance test for elements of building construction-general requirements, 1-30
  12. Oh, J., Ju, M., Seo, S., Kim, S., Lim, K., & Park, C. (2014). Fire safety analysis of the concrete bridge structure with standard fire curve and real scale fire curve, Proceedings of the Korea Concrete Institute, 26(1), 69-70
  13. Korean Industrial Standards(2014), KS F 2257-6: Methods of fire resistance test for elements of building construction-specific requirements forements for beams, 1-20
  14. Kim, D., Han, B., Lee, J., Harada, K., & Kwon, Y. (2011). The influence of compressive strength and moisture contents on explosive spalling of concrete, Fire Science and engineering, 25(1), 42-49
  15. Saito, H. (1966). Explosive spalling of prestressed concrete in fire, Bull. of The Fire Prevention Society of Japan, 15(2), 23-30
  16. Choi, Y., Chae, I., Kang, Y., Won, J., Kim, J., & Kim, S. (2011). Tuning thermal expansion coefficient of composites containing epoxy resin/inorganic additives for stone consercation, Journal of conservation science, 27(4), 431-440
  17. Hwang, J., & Kwak, H. (2015). A numerical model of reinforced concrete members exposed to fire and After-cooling analysis, Journal of the computational structural engineering institute of Korea, 28(1), 101-113 https://doi.org/10.7734/COSEIK.2015.28.1.101
  18. British Standards Institution(1985), BS8110: Structural use of concrete, 1-10
  19. Seo, S., Choi, K., & Kwo, Y. (2012). Retrofit capacity of near-surface-mounted RC beam by using FRP plate, Journal of the Korea institute for structural maintenance and inspection, 16(1), 18-26 https://doi.org/10.11112/jksmi.2012.16.1.018