Abstract

Countermeasures against earthquake disasters such as the seismic capacity evaluation and/or retrofit schemes of buildings, especially existing low-rise reinforced concrete buildings, have not been fully performed since Korea had not experienced many destructive earthquakes in the past. However, due to more than 1200 earthquakes with low or moderate intensity in the off-coastal and inland of Korea during the past 20 years, and due to the recent moderate earthquakes in Korea, such as the 2016 Gyeongju Earthquake with M=5.8 and the 2017 Pohang Earthquake with M=5.4, the importance of the future earthquake preparedness measures is highly recognized in Korea. The main objective of this study is to provide the basic information regarding seismic capacities of existing low-rise reinforced concrete buildings in Korea. In this paper, seismic capacities of 14 existing low-rise reinforced concrete public buildings in Korea are evaluated based on the Japanese Standard for Evaluation of Seismic Capacity of Existing Reinforced Concrete Buildings. Seismic capacities between existing buildings in Korea and those in Japan is compared, and the relationship of seismic vulnerability of Korean buildings and Japanese buildings damaged due to severe earthquakes are also discussed. Results indicated that Korean existing low-rise reinforced concrete buildings have a narrow distribution of seismic capacities and they are relatively lower than Japanese buildings, and are also expected to have severe damage under the earthquake intensity level experienced in Japan. It should be noted from the research results that the high ductility in Korean existing low-rise buildings obtained from the Japanese Standard may be overestimated, because most buildings investigated herein have the hoop spacing wider than 30 cm. In the future, the modification of strength and ductility indices in the Japanese Standard to propose the seismic capacity evaluation method of Korean buildings is most needed.

Keywords

References

  1. JBDPA. (2001) Standard for Evaluation of Seismic Capacity of Existing Reinforced Concrete Buildings. Tokyo, Japan: Japan Building Disaster Prevention Association, p.300.
  2. JBDPA. (2005) Standard for Seismic Evaluation of Existing Reinforced Concrete Buildings, Guidelines for Seismic Retrofit of Existing Reinforced Concrete Buildings, and Technical Manual for Seismic Evaluation and Seismic Retrofit of Existing Reinforced Concrete Buildings. Tokyo, Japan: Japan Building Disaster Prevention Association, p.200.
  3. SPRC Committee. (1980) Computational Program for Seismic Evaluation of Existing Reinforced Concrete Buildings (Screen Edition-2). Tokyo, Japan: Japan Building Disaster Prevention Association.
  4. Lee, K.S., Nakano, Y., Kumazawa, F., Okada, T. (1996a) A Study on Seismic Capacity of Existing Reinforced Concrete Buildings. Journal of Institute of Industrial Science (Seisan-Kenkyu), 48(11), University of Tokyo, 10-20.
  5. AIJ. (2010) Design Code of Reinforced Concrete Buildings. Tokyo, Japan: Architectural Institute of Japan, p.340.
  6. Etawa, M.A.E, Kubo, T., Ueno, K. (1998) Seismic capacity of reinforced concrete buildings evaluated based on the basic structural index and nonlinear seismic analysis: Focused on buildings controlled by shear. Proceedings of the Architectural Institute of Japan Annual Convention, C-2, 63-64.
  7. Kubo, T. and Etawa, M. A. E. (1999) Seismic capacity of reinforced concrete buildings evaluated based on the basic structural index and nonlinear seismic analysis: Focused on buildings controlled by flexure. Proceedings of the Architectural Institute of Japan Annual Convention, C-2, 269-270.
  8. Kubo, T., Akagi, T., Ueno, K., Etawa, M.A.E. (1998) Seismic capacity of reinforced concrete buildings constituted of flexural and shear failure members: Seismic capacity evaluation of seismic screening standards in Japan. Proceedings of the Tenth Japan Earthquake Engineering Symposium, 3273-3278.
  9. AIJ. (1968) Report on Damage Due to the 1968 Tokachi-oki Earthquake. Tokyo, Japan: Architectural Institute of Japan, p480.
  10. Shiga, T., Shibata, A., Takahashi, T. (1968) Earthquake damage and wall index of reinforced concrete buildings. Proceedings of Tohoku District Symposium of Architectural Institute of Japan, 12, 29-32.
  11. Shiga, T. (1978) Earthquake damage and number of walls in reinforced concrete structures. Proceedings of Natural Hazard Data Analysis Symposium II in Sendai City, Japan, 46-55.
  12. Okada, T. (1985) Seismic capacity of existing reinforced concrete buildings and decision criteria for strengthening. Proceedings of the First Workshop on Seismic Performance of Existing Buildings, Department of Structural Engineering, Cornell University, Ithaca, New York, 86-93.
  13. Lee, K.S., Nakano, Y., Kumazawa, F., Okada, T. (1996b) Seismic Capacity of Reinforced Concrete Buildings Damaged by Hyogo-ken Nambu Earthquake 1995 (Seismic Capacity of Reinforced Concrete Buildings in Awaji Island). Journal of Structural Engineering, Architectural Institute of Japan and Japan Society of Civil Engineers, 42B, 55-65.