DOI QR코드

DOI QR Code

겨울철 젊은이와 노인의 선호 바닥온도 비교

Comparison of the Preference for Floor Temperature between Young and Old People in a Winter Season

  • 안태경 (경동대학교 건축공학과)
  • Ahn, Tae-Kyung (Deapartment of Architectural Engineering, Kyung Dong University)
  • 투고 : 2018.03.10
  • 심사 : 2018.05.21
  • 발행 : 2018.05.25

초록

Even in modern times, we are accustomed to the lifestyle of floor heating system in which the floor is heated for warmth like Ondol, which is the traditional Korean heating system. So, this study was designed to understand the preferred floor temperature through the questionnaires targeting the local residents living in K region. This study would also find out the floor temperature which is preferred by young people and old people through the experiments. The findings are as follows; (1) the old people do not prefer the temperature higher than young people do. It was found that the old people prefer the floor temperature of $40^{\circ}C$ under the air temperature of $20^{\circ}C$ or the floor temperature of $41^{\circ}C$ under the air temperature of $20^{\circ}C$. (2) Both young people and old people tend to like the average skin temperature of $35.5^{\circ}C$. The skin temperature which both young and old people like was $35.2^{\circ}C$ under the air temperature of $24^{\circ}C$ and the skin temperature preferred by young people was $0.4^{\circ}C$ higher than that preferred by under the air temperature of $20^{\circ}C$ (p<0.01). (3) It was found in the questionnaires that the young people prefer the higher floor temperature in terms of age and that the people who get older in their 50s or higher tend to prefer the lower temperature.

키워드

참고문헌

  1. Bae, S.H., Park, T.S., Yoon, J.O. and Lee, K.H. Field survey on the thermal environment of folk house in middle region. In: Lee, M.-H. (ed.) Proceeding of AIK 1995, Vol. 15, Seoul, AIK Annual Conference, 1995
  2. Chun, C.Y., Teruaki, M. and Kazuo, F. A research on the indoor thermal environment in living room with radiant floor heating system: case study in Korea and Japan, J. Korean Housing Assoc, 16, 2005
  3. Danno, K., Mori, N., Toda, K.I., Kobayashi, T., Utani, A., Near-infrared irradiation stimulates cutaneous wound repair: laboratory experiments on possible mechanisms. Photodermatol. Photo. 17(6), 2001
  4. Park, S.H., Kim, N.H. and Sohn, J.Y. ,The thermal environment characteristics of the traditional ONDOL space on the Chung Hyu Dang. In: Jeong, J.-C. (ed.) Proceeding of AIK (Planning and Design) 2001, Vol. 21, Seoul, Annual Conference of AIK, 2001
  5. Sohn, J.Y., Huh, J.H. and Kim, H.S. A Study on the measurement of thermal environment in the traditional folk residence of Cho-Sun Dynasty: focusing on the Oe-Am Ri in spring and summer, J. AIK, 2, 1986
  6. Toyokawa, H., Yoichi, M.Y., Uhara, J., Tsuchiya, H., Teshima, S., Nakanishi, H., Kwon, A., Azuma, Y., Nagaoka, T., Ogawa, T., Kamiyama, Y., 2003. Promotive Effects of Far-Infrared Ray on Full-Thickness Skin Wound Healing in Rats. Exp. Biol. Med. 288(6)
  7. Kang SW, Jeon JH, Shin YG, Min BC, Kook C. A Study on the Thermal Sensation Vote of the Traditional Housing in Winter, In: Proceedings of the KIEAE , Seoul, Annual conference of KIEAE, 2006
  8. Kim, M.S., Kim, J.T. and Park, H.S. A study on the conservative building improvements for indoor thermal environment in a traditional house of Genjaegotaek, J. AIK (Planning and Design), 20, 2004, pp. 251-258
  9. Kwak, H., Lee, S.Y. and Kim, S.B. Therapeutic heat and cryotherapy in family medicine, J. Korean Acad. Farm. Med., 24, 2003
  10. Masuda, A., Kihara, T., Fukudome, T., Shinsato, T., Minagoe, S. and Tei, C. The effect of repeated thermal therapy for two patients with chronic fatigue syndrome, J. Psychosom. Res., 58, 2005
  11. Yu, S.Y., Dhiu, J.H., Yang, S.D., Hsu, Y.C., Lui, W.Y., and Wu, C.W. Biological effct of far-infrared therapy on increasing skin microcirculation in rats, Photodermatol Photoimmunol Photomed, 22, 2006
  12. Yeo, H.S., Kim, N.H. and Sohn, J.Y. The evaluation of indoor thermal environmental characteristics in the traditional ONDOL heating system. In: Kim, J.-K. (ed.) Proceeding of AIK 2003, Vol. 23, Seoul, Annual Conference of AIK, 2003
  13. Yeo, M.S., Kim, K.W., Seok, H.T. and Jang, K.H. A study on the historical changes and evolution of traditional ONDOL, J. AIK, 11, 1995
  14. Parsons, K. Human thermal environments, 3rd edn. Taylor & Francis, New York. 2014
  15. MOLIT. Standard for the energy saving in buildings, MOLIT official announcement No. 2017-71