저장탄약신뢰성평가 데이터를 이용한 기계식시한신관 KM577A1 저장수명 추정 연구

A Study on the Estimation of Shelf Life for Fuze MTSQ KM577A1 from ASRP Data

  • 투고 : 2017.08.18
  • 심사 : 2018.03.14
  • 발행 : 2018.03.25

초록

Purpose: The purpose of this study is to estimate shelf life of fuze MTSQ (Mechanical Time & Super Quick) KM577A1 from Ammunition Stockpile Reliability Program (ASRP) data. Methods: For many years, ammunition test data had been gathered from ASRP. In this study, lot selection criteria and reliability score of functioning time for fuze are proposed. Reliability score of functioning time and failure data are used to estimate shelf life. Results: The results of this study are as follows; The failure modes of fuze MTSQ KM577A1 are dud, inverse function and mechanical time functioning failure (not operating in intended time). Dud and inverse function are major failure modes. Fuze MTSQ KM577A1's shelf life ($B_5$) is estimated 18.2 years conservatively. Conclusion: Degradation of chemical components in fuze MTSQ KM577A1 is major factor for its reliability. And shelf life ($B_5$) of fuze MTSQ KM577A1 is estimated 18.2 years conservatively.

키워드

참고문헌

  1. Kim, Y. S. et al. (2010). "Introduction to Defense Quality Management". Hyungseul Publishing Network.
  2. Yoon, K. S. and Lee, J. C. (2012). "A Case Study on the Reliability Assessment of Stockpile Ammunition". Journal of the Korean Society for Quality Management, Vol. 40, No. 3, pp. 259-269. https://doi.org/10.7469/JKSQM.2012.40.3.259
  3. Yoon, K. S. and Park, S. W. (2014). "A Study on the Estimation of Shelf-life for 155mm Propelling Charge KM4A2 using ASRP's Data". Jounal of the Korean Society for Quality Management, Vol. 42, No. 3, pp. 291-300. https://doi.org/10.7469/JKSQM.2014.42.3.291
  4. Chang, I. H. et al. (2010). "Storage Lifetime Estimation of Detonator in Fuze MTSQ KM577A1". Journal of the Korean Society for Quality Management, Vol. 38, No. 4, pp. 504-511.
  5. Bong, H. G. and Yoon, K. S. (2005). "The Study for the Single-based Propellant Shelf Life Extension". Journal of Applied Reliability, Vol. 3, No. 3, pp. 357-371.
  6. Park, J. M., Lee, H. C., and Pack, S. C. (2017). "Determination of the Initial Test Years for One-shot System using Validity Assessment of Drugs". Journal of Applied Reliability, Vol. 17, No. 1, pp. 1-10.
  7. Hong, J. T. (2011). "Technology of Modern Munitions". Bonn Design.
  8. Jane's Ammunition Handbook (2017). "Fuze-Artillery-Fuzes". Last modified July 21. https://janes.ihs.com/Def enceEquipment/Display/1333194.
  9. Chung, Y. H. et al. (2016). "Influence Analysis of Sampling Points on Accuracy of Storage Reliability Estimation for One-shot Systems". Journal of Applied Reliability, Vol. 16, No. 1, pp. 32-40.
  10. Seo, S. K. (2015). "Minitab Reliability Analysis". Eretec Inc.
  11. Park, J. W. and Ham, J. K. (2006). "Development of Reliability Index for Comparison of Components' Reliability". 2006 Spring Conference Proceedings of the Korean Reliability Society, pp. 140-148.
  12. Sherwin, E. R. (2004). "Analysis of "One-Shot" Devices". Selected Topics in Assurance Related Technologies, Vol. 7, No. 4, pp. 1-4.
  13. Sim, H. G., Park, S. G., and Son, Y. K. (2009). "A Study on the Reliability Analysis of One-shot System". Journal of the Korea Association of Defense Industry Studies, Vol. 16, No. 2, pp. 105-116.
  14. Ulrike, G. and Wiliam, Q. M. (2010). "A Comparison of Maximum Likelihood and Median-rank Regression for Weibull Estimation". Quality Engineering, Vol. 22, No. 4, pp. 236-255. https://doi.org/10.1080/08982112.2010.503447
  15. Park, D. S. et al. (2006). "The Report on the ASRP's Activities in 2005". Defense Agency for Technology and Quality, DTaQ-06-1213-T.
  16. Na, S. E. et al. (2007). "The Report on the ASRP's Activities in 2006". Defense Agency for Technology and Quality, DTaQ-07-1348-T.
  17. Koo, W. S. et al. (2014). "The Report on the ASRP Activities for the Army Ammunition in 2013". Defense Agency for Technology and Quality, DTaQ-14-4237-T.
  18. Yoon, K. S. et al. (2011). "The Report on the Army ASRP's Activities in 2010". Defense Agency for Technology and Quality, DTaQ-11-2810-T.