참고문헌
- http://www.eljentechnology.com/products/liquid-scintillators/ej-301-ej-309.pdf.
-
B. Wan, X.Y. Zhang, L. Chen, H.L. Ge, F. Ma, H.B. Zhang, Y.Q. Ju, Y.B. Zhang, Y.Y. Li, X.W. Xu, Digital pulse shape discrimination methods for n -
$\gamma$ separation in an EJ-301 liquid scintillation detector, Chin. Phys. C 39 (11) (2015) 116201. https://doi.org/10.1088/1674-1137/39/11/116201 - G.F. Knoll, Radiation Detection and Measurement, John Wiley & Sons, 2010.
- C.S. Sosa, M. Flaska, S.A. Pozzi, Comparison of analog and digital pulse-shapediscrimination systems, Nucl. Instrum. Meth. A 826 (2016) 72-79. https://doi.org/10.1016/j.nima.2016.03.088
- A. Rahmat, L.R. Edward, F.S. David, Development of a handheld device for simultaneous monitoring of fast neutrons and gamma rays, IEEE Trans. Nucl. Sci. 49 (4) (2002) 1909-1913. https://doi.org/10.1109/TNS.2002.801508
- M. Nakhostin, P.M. Walker, Application of digital zero-crossing technique for neutron gamma discrimination in liquid organic scintillation detectors, Nucl. Instrum. Meth. A 621 (2010) 498-501. https://doi.org/10.1016/j.nima.2010.06.252
- B.D. Mellow, M.D. Aspinall, R.O. Mackin, M.J. Joyce, A.J. Peyton, Digital discrimination of neutrons and g-rays in liquid scintillators using pulse gradient analysis, Nucl. Instrum. Meth. A 578 (2007) 191-197.
- M.L. Roush, M.A. Wilson, W.F. Hornyak, Pulse shape discrimination, Nucl. Instr. Meth. 31 (1964) 112-124. https://doi.org/10.1016/0029-554X(64)90333-7
-
G. Liu, M.J. Joyce, X. Ma, M.D. Aspinall, A digital method for the discrimination of neutrons and
$\gamma$ rays with organic scintillation detectors using frequency gradient analysis, IEEE Trans. Nucl. Sci. 57 (2010) 1682-1691. https://doi.org/10.1109/TNS.2010.2044246 - A. Moslem, P. Vaclav, C. Frantisek, M. Zdenek, M. Filip, Quick algorithms for real-time discrimination of neutrons and gamma rays, J. Radioanal. Nucl. Chem. 303 (2015) 583-599. https://doi.org/10.1007/s10967-014-3406-5
- M.J. Safari, D.F. Abbasi, H. Afarideh, S. Jamili, E. Bayat, Discrete fourier transform method for discrimination of digital scintillation pulses in mixed neutron-gamma fields, IEEE Trans. Nucl. Sci. 63 (1) (2016) 325-332. https://doi.org/10.1109/TNS.2016.2514400
- D. Takaku, T. Oishi, M. Baba, Development of neutron-gamma discrimination technique using pattern-recognition method with digital signal processing, Prog. Nucl. Sci. Technol 1 (2011) 210-213. https://doi.org/10.15669/pnst.1.210
- E. Bayat, N. Divani-Vais, M.M. Firoozabadi, N. Ghal-Eh, A comparative study on neutron-gamma discrimination with NE213 and UGLLT scintillators using zero-crossing method, Radiat. Phys. Chem. 81 (2012) 217-220. https://doi.org/10.1016/j.radphyschem.2011.10.016
- R.A. Winyard, G.W. McBeth, Nucl. Instrum. Meth. 98 (1972) 525-533. https://doi.org/10.1016/0029-554X(72)90238-8
- J. Cerny, Z. Dolezal, M.P. Ivanov, E.S. Kuzmin, J. Svejda, I. Wilhelm, Study of neutron response and n-g discrimination by charge comparison method for small liquid scintillation detector, Nucl. Instrum. Meth. A 527 (2004) 512-518. https://doi.org/10.1016/j.nima.2004.03.179
- http://www.ortec-online.com/products/electronics/preamplifiers.
- http://www.canberra.com/products (accessed 11 September 2017).
- S.D. Jastaniah, P.J. Sellin, Digital pulse-shape algorithms for scintillation-based neutron detectors, IEEE Trans. Nucl. Sci. 49 (4) (2002) 1824-1828. https://doi.org/10.1109/TNS.2002.801674
- https://www.hamamatsu.com/resources/pdf/etd/R9420TPMH1296E.pdf.
- IEEE Standard Test Procedures for Amplifiers and Preamplifiers Used With Detectors of Ionizing Radiation, IEEE Std 301-1988.
-
K. Gul, A.A. Naqvi, A.H. Al-Juwair, Relative neutron detector efficiency and response function measurements with a
${252}^Cf$ neutron source, Nucl. Instrum. Meth. A 278 (1989) 470-476. https://doi.org/10.1016/0168-9002(89)90867-X - A.N. Lurie, J.L. Harris, C.J. Young, Calculation of Gamma-Ray response matrix for 5 cm NE-213 organic liquid scintillation detector, Nucl. Instrum. Meth. 129 (1975) 543-555. https://doi.org/10.1016/0029-554X(75)90750-8
- A.S. Pozzi, M.M. Bourne, D.S. Clarke, Pulse shape discrimination in the plastic scintillator EJ-299-33, Nucl. Instrum. Meth. A 723 (2013) 19-23. https://doi.org/10.1016/j.nima.2013.04.085